Evaluation of Conformity and Homogeneity Indices Consistency Throughout the Course of Head and Neck Cancer Treatment With and Without Using Adaptive Volumetric Modulated Arc Radiation Therapy

被引:7
|
作者
Al-Rawi, Salam Abdulrazzaq Ibrahim [1 ,3 ]
Abouelenein, Hassan [2 ]
Khalil, Magdy Mohammed [3 ,5 ]
Alabdei, Haidar Hamza [1 ,4 ]
Sulaiman, Awf Abdulrahman [1 ]
Al-Nuaimi, Dalya Saad [1 ]
El Nagdy, Mohamed El-Sayed [3 ]
机构
[1] Minist Hlth Environm, Baghdad Med City Complex, Baghdad Radiat Oncol & Nucl Med Ctr, Dept Radiat Oncol, Baghdad, Iraq
[2] Saudi German Hosp, Radiotherapy Dept, Cairo, Egypt
[3] Helwan Univ, Fac Sci, Dept Phys, Cairo, Egypt
[4] Baghdad Univ, Coll Med, Dept Surg, Baghdad, Iraq
[5] Badr Univ Cairo BUC, Sch Biotechnol, Dept Biotechnol, Cairo, Egypt
关键词
RADIOTHERAPY; QUALITY;
D O I
10.1016/j.adro.2022.100905
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Conformity indices (CI) and homogeneity indices (HI) are important tools for evaluating treatment plan quality. In this study, we evaluate the consistency of these indices with respect to anatomic changes undergone by patients. Methods and Materials: Fifty-five patients with advanced head and neck cancer were treated with simultaneous integrated boost volumetric modulated arc therapy. The initial plan (iplan) then was projected on the new computed tomography (CT) and 2 adaptive plans (Aplans) for each patient were performed on the new CTs. A comparison of CI and HI between the iplan, hybrid plan (Hplan), and Aplan was performed. Results: There was a significant weight loss (P < .001) between CT1, CT2, and CT3, where the median weight at CT1 was 75.78 (68.95-83.42) kg, and 74.88 (68.35-82.2) kg at CT2 and 73.1 (67.6-80.7) kg at CT3. Also, gross tumor volume (GTV) showed significant decrease at CT1, CT2, and CT3. The initial GTV was 32.3 (21-58.6) cc and 28.24 (15.85-48.63) cc at CT2 and 25.12 (14.1-42.2) at CT3. In addition, there was a significant decrease in left parotid volume after 10 and 20 fractions; the median left parotid gland volume at CT1 was 31.04 (26.34-36.27) cc, then was 25.84 (19.19-28.59) cc after 10 fractions and 19.5 (13.53-22.25) cc after 20 fractions; the median right parotid volume at CT1 was 29.81 (24.6-38.75) cc and 22.38 (18.19-30.12) cc at CT2, then the volume fell to 17.74 (13.41-22.66) cc at CT3. Also, a significant increase in dose to organs at risk were noticed at Hplans, the median dose for brain stem at iplan was 5156 (4561-5324) cGy then increased to 5321 (4688-5545) cGy at Hplan1 then increased again to reach 5401 (4821-5812) cGy at Hplan2. The CI showed regression at Hplan1 and Hplan2 and then improvement at Aplan1 and Aplan2. The HI also showed regression in its value at the Hplans and then improved at the Aplans. Conclusions: Based on the results, we conclude that anatomic changes such as weight loss greatly affect the quality of plan, and with Aplans, we maintained the quality of plan by sustaining the values of CI and HI as in the iplan (C) 2022 The Author(s). Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Adaptive Radiotherapy in Head and Neck Cancer Using Volumetric Modulated Arc Therapy
    Buciuman, Nikolett
    Marcu, Loredana G.
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (05):
  • [2] Volumetric Modulated Arc Therapy for Head & Neck Cancer
    Afghan, M. K. N.
    Cao, D.
    Mehta, V.
    Shepard, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2901 - +
  • [3] Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer
    Alvarez-Moret, Judith
    Pohl, Fabian
    Koelbl, Oliver
    Dobler, Barbara
    [J]. RADIATION ONCOLOGY, 2010, 5
  • [4] Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer
    Judith Alvarez-Moret
    Fabian Pohl
    Oliver Koelbl
    Barbara Dobler
    [J]. Radiation Oncology, 5
  • [5] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [6] Adaptive Volumetric-Modulated Arc Radiation Therapy for Head and Neck Cancer: Evaluation of Benefit on Target Coverage and Sparing of Organs at Risk
    Franzese, Ciro
    Tomatis, Stefano
    Bianchi, Sofia Paola
    Pelizzoli, Marco
    Teriaca, Maria Ausilia
    Badalamenti, Marco
    Comito, Tiziana
    Clerici, Elena
    Franceschini, Davide
    Navarria, Pierina
    Di Cristina, Luciana
    Dei, Damiano
    Galdieri, Carmela
    Reggiori, Giacomo
    Mancosu, Pietro
    Scorsetti, Marta
    [J]. CURRENT ONCOLOGY, 2023, 30 (03) : 3344 - 3354
  • [7] Limitations of Optimization Algorithm With Volumetric Modulated Arc Technique for Head and Neck Cancer Radiation Therapy
    Xue, J.
    Wu, P.
    Kryger, M.
    Wang, W.
    Cheng, P.
    Das, I. J.
    Hu, K. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E741 - E741
  • [8] Plan Robustness Study of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S. H.
    Shen, J.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W. W.
    Halyard, M. Y.
    Ezzell, G. A.
    Schild, S. E.
    Bues, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E567 - E568
  • [9] Volumetric Modulated Arc Therapy Optimization Strategy for a Head and Neck Cancer
    Singh, N.
    Ahamed, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E290 - E290
  • [10] Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol
    Tam, Dang Thi Minh
    Ho, Phan Long
    Uy, Phan Quoc
    Hieu, Nguyen Trung
    Linh, Vo Tan
    Hoa, Nguyen Thi
    Lam, Nguyen Thi The
    Nga, Bui Thi Thuy
    Thanh, Truong Huu
    Thanh, Tran Thien
    Tao, Chau Van
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024,