A New Hydrogen Sensor Based on SNS Fiber Interferometer with Pd/WO3 Coating

被引:18
|
作者
Shao, Jin-xin [1 ]
Xie, Wen-ge [1 ]
Song, Xi [1 ]
Zhang, Ya-nan [1 ,2 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
[2] State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Peoples R China
来源
SENSORS | 2017年 / 17卷 / 09期
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
fiber interferometer; no core fiber (NCF); hydrogen sensor; Pd/WO3; film; TECHNOLOGY; ENERGY; FILM;
D O I
10.3390/s17092144
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a new hydrogen sensor based on a single mode-no core-single mode (SNS) fiber interferometer structure. The surface of the no core fiber (NCF) was coated by Pd/WO3 film to detect the variation of hydrogen concentration. If the hydrogen concentration changes, the refractive index of the Pd/WO3 film as well as the boundary condition for light propagating in the NCF will all be changed, which will then cause a shift into the resonant wavelength of interferometer. Therefore, the hydrogen concentration can be deduced by measuring the shift of the resonant wavelength. Experimental results demonstrated that this proposed sensor had a high detection sensitivity of 1.26857 nm/%, with good linearity and high accuracy (maximum 0.0055% hydrogen volume error). Besides, it also possessed the advantages of simple structure, low cost, good stability, and repeatability.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Sagnac interferometer hydrogen sensor based on panda fiber with Pt-loaded WO3/SiO2 coating
    Xu, Ben
    Zhao, C. L.
    Yang, Fan
    Gong, Huaping
    Wang, D. N.
    Dai, JiXiang
    Yang, Minghong
    [J]. OPTICS LETTERS, 2016, 41 (07) : 1594 - 1597
  • [2] Ultra-highly sensitive hydrogen sensor based on fiber Fabry-Perot interferometer with Pt/WO3 coating
    Wang, Yao
    Yang, Minghong
    Zhang, Guilin
    Dai, Jixiang
    Zhang, Yi
    Zhuang, Zhi
    [J]. 23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157
  • [3] Hydrogen sensor based on high-birefringence fiber loop mirror with sol-gel Pd/WO3 coating
    Zhang, Ya-nan
    Peng, Huijie
    Zhou, Tianmin
    Zhang, Lebin
    Zhang, Yuyan
    Zhao, Yong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 248 : 71 - 76
  • [4] Fiber Optic Hydrogen Sensor Based on Fabry-Perot Interferometer Coated With Sol-Gel Pt/WO3 Coating
    Wang, Yao
    Yang, Minghong
    Zhang, Guilin
    Dai, Jixiang
    Zhang, Yi
    Zhuang, Zhi
    Hu, Wenbin
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2015, 33 (12) : 2530 - 2534
  • [5] SAW hydrogen gas sensor based on WO3 and Pd nanostructures
    Jakubik, Wieslaw
    Urbanczyk, Marian
    Maciak, Erwin
    [J]. PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 200 - 203
  • [6] Miniature Hydrogen Sensor Based on Fiber Inner Cavity and Pt-doped WO3 Coating
    Hu, Tian Yi
    Wang, D. N.
    Wang, Min
    Li, Zhi
    Yang, Minghong
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (14) : 1458 - 1461
  • [7] Highly sensitive hydrogen sensor based on an in-fiber Mach-Zehnder interferometer with polymer infiltration and Pt-loaded WO3 coating
    Du, Bin
    He, Jun
    Yang, Minghong
    Wang, Ying
    Xu, Xizhen
    Wang, Jiachen
    Zhang, Zhe
    Zhang, Fengchan
    Guo, Kuikui
    Wang, Yiping
    [J]. OPTICS EXPRESS, 2021, 29 (03) : 4147 - 4158
  • [8] Hydrogen sensor based on MWNTs/WO3
    Azam, Iraji Zad
    Roghayeh, Ghasempour
    [J]. 2011 IEEE SENSORS, 2011, : 5 - 7
  • [9] Fabrication of Pd Doped WO3 Nanofiber as Hydrogen Sensor
    Nikfarjam, Alireza
    Fardindoost, Somayeh
    Zad, Azam Iraji
    [J]. POLYMERS, 2013, 5 (01) : 45 - 55
  • [10] Optical fiber hydrogen sensor based on evaporated Pt/WO3 film
    Li, Zhi
    Yang, Minghong
    Dai, Jixiang
    Wang, Gaopeng
    Huang, Chujia
    Tang, Jianguan
    Hu, Wenbin
    Song, Han
    Huang, Pengcheng
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 564 - 569