Instrumentation and monitoring of segmental post-tensioned girders

被引:0
|
作者
Gomez, Roberto [1 ]
Alberto Escobar, J. [1 ]
Guerrero, Hector [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Engn, Struct Engn Dept, Mexico City 04510, DF, Mexico
关键词
D O I
10.1088/1757-899X/236/1/012062
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As a result of the failure of prefabricated segmental girders during their construction, and in order to evaluate the structural safety of the superstructures of three bridges, different activities of instrumentation, monitoring and mathematical modelling were performed. This paper presents the first stage of a study describing the tasks of instrumentation and monitoring of stresses in an isolated precast post-tensioned beam during the process of application of the tension loading, and before being placed in its final position. The main goal of this task was to confirm the transmission and distribution of stresses at segmental joints. Also, ambient vibration tests were carried out in different phases of tensioning, as well as in the final position of the girder. Recorded stories of accelerations are presented and fundamental periods of vibrating of the isolated girder are derived. The results of the measurements will be used for the calibration of mathematical models and simulation of different scenarios of loads and thus assess the structural safety of the different sections of the superstructures of the three bridges in question.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Experimental Investigation of Segmental Post-tensioned Girders
    Allawi, Abbas
    Al-Sherrawi, Mohannad
    AL-Bayati, Basim
    Al Gharawi, Mohanned
    El-Zohairy, Ayman
    [J]. CHALLENGES IN MECHANICS OF TIME-DEPENDENT MATERIALS (2018), VOL 2, 2019, : 87 - 94
  • [2] LAUNCHER ERECTS POST-TENSIONED GIRDERS
    STERGIOU, P
    [J]. CIVIL ENGINEERING, 1967, 37 (08): : 66 - &
  • [3] Shear Behavior of Post-Tensioned Girders
    Moore, A. M.
    Williams, C. S.
    Massey, J. B.
    Bayrak, O.
    Ghannoum, W. M.
    Jirsa, J. O.
    [J]. ACI STRUCTURAL JOURNAL, 2017, 114 (06) : 1615 - 1625
  • [4] PRE-TENSIONED AND POST-TENSIONED COMPOSITE GIRDERS
    TROITSKY, MS
    ZIELINSKI, ZA
    NOURAEYAN, A
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1989, 115 (12): : 3142 - 3153
  • [5] Preliminary Design of Post-Tensioned Transfer Girders
    Uzel, Almila
    [J]. PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2020, 25 (04)
  • [6] Testing of post-tensioned concrete girders in the framework of monitoring with fibre optic sensors
    Matthys, S
    Taerwe, L
    [J]. STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2003, : 321 - 328
  • [7] Findings from in-situ survey of post-tensioned precast and segmental post-tensioned bridges
    Gasparek, Jakub
    Paulik, Peter
    Kopasek, Denis
    [J]. STRUCTURES, 2024, 68
  • [8] Dynamic characteristics of post-tensioned girders with web openings
    Grace, NF
    Ross, B
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (06): : 643 - 650
  • [9] SEGMENTAL POST-TENSIONED DOLPHIN AT TAGRIN POINT
    MATTAR, SG
    [J]. JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT-ASCE, 1983, 109 (03): : 276 - 285
  • [10] OREGON GETS A SEGMENTAL POST-TENSIONED BRIDGE
    PIERCE, LF
    [J]. CIVIL ENGINEERING, 1972, 42 (03): : 67 - &