Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty

被引:6
|
作者
Weber, Markus [1 ]
Woerner, Michael L. [1 ]
Sendtner, Ernst [2 ]
Voellner, Florian [1 ]
Grifka, Joachim [1 ]
Renkawitz, Tobias F. [1 ]
机构
[1] Univ Regensburg, Med Ctr, Dept Orthoped Surg, Bad Abbach, Germany
[2] Vilsbiburg Hosp, Dept Orthoped & Trauma Surg, Vilsbiburg, Germany
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 11期
关键词
combined anteversion; femur first; impingement; range of motion; total hip arthroplasty; FREE RANGE; MOTION; NAVIGATION; IMPACT;
D O I
10.1016/j.arth.2016.04.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In this prospective study of 66 patients undergoing cementless total hip arthroplasty through a minimally invasive anterolateral approach, we evaluated the impact of an intraoperative hybrid combined anteversion technique on postoperative range of motion (ROM). Methods: After navigation of femoral stem anteversion, trial acetabular components were positioned manually, and their position recorded with navigation. Then, final components were implanted with navigation at the goals prescribed by the femur-first impingement detection algorithm. Postoperatively, three-dimensional computed tomographies were performed to determine achieved component position and model impingement-free ROM by virtual hip movement, which was compared with published values necessary for activities of daily living. This model was run a second time with the implants in the position selected by the surgeon rather than the navigation program. In addition, we researched into risk factors for ROM differences between the freehand and navigated cup position. Results: We found a lower flexion of 8.3 degrees (8.8 degrees, P < .001) and lower internal rotation of 9.2 degrees (9.5 degrees, P < .001) for the freehand implanted cups in contrast to a higher extension of 9.8 degrees (11.8 degrees, P < .001) compared with the navigation-guided technique. For activities of daily living, 58.9% (33/56) in the freehand group compared with 85.7% (48/56) in the navigation group showed free flexion (P < .001) and similarly 50.0% (28/56) compared with 76.8% (43/56) free internal rotation (P < .001). Body mass index, incision length, and cup size were identified as independent risk factors for reduced flexion and internal rotation in the freehand group. Conclusion: For implementation of a combined anteversion algorithm, intraoperative alignment guides for accurate cup positioning are required using a minimally invasive anterolateral approach. Obese patients are especially at risk of cup malpositioning. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:2514 / 2519
页数:6
相关论文
共 50 条
  • [1] Intraoperative estimation of femoral anteversion in cementless total hip arthroplasty using the lesser trochanter
    Unlu, Mehmet C.
    Kesmezacar, Hayrettin
    Kantarci, Fatih
    Unlu, Burcin
    Botanlioglu, Huseyin
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1317 - 1323
  • [2] Intraoperative estimation of femoral anteversion in cementless total hip arthroplasty using the lesser trochanter
    Mehmet C. Unlu
    Hayrettin Kesmezacar
    Fatih Kantarci
    Burcin Unlu
    Huseyin Botanlioglu
    [J]. Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1317 - 1323
  • [3] A Novel Device for Intraoperative Measurement of Stem Anteversion Angle in Total Hip Arthroplasty
    Iwakiri, Kentaro
    Ohta, Yoichi
    Ueno, Shuhei
    Minoda, Yukihide
    Kobayashi, Akio
    Nakamura, Hiroaki
    [J]. ARTHROPLASTY TODAY, 2024, 28
  • [4] Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level
    Anuwat Pongkunakorn
    Nawakun Phetpangnga
    Narawit Kananai
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [5] Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level
    Pongkunakorn, Anuwat
    Phetpangnga, Nawakun
    Kananai, Narawit
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [6] Surgeon Error in Performing Intraoperative Estimation of Stem Anteversion in Cementless Total Hip Arthroplasty
    Hirata, Masanobu
    Nakashima, Yasuharu
    Ohishi, Masanobu
    Hamai, Satoshi
    Hara, Daisuke
    Iwamoto, Yukihide
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1648 - 1653
  • [7] Femoral anteversion change is associated with ischiofemoral impingement after total hip arthroplasty: a retrospective CT evaluation
    Marth, Adrian A.
    Goller, Sophia S.
    Sutter, Reto
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (06) : 3529 - 3537
  • [8] Successful reconstruction of natural femoral anteversion using a short femoral stem in total hip arthroplasty surgery
    Hakim, Raja
    Weinstein, Aryeh
    Dabby, Dan
    Rozen, Nimrod
    Shabshin, Nogah
    Rubin, Guy
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2022, 50 (04)
  • [9] Accuracy of femoral component anteversion in robotic total hip arthroplasty
    Sugano, Nobuhiko
    Maeda, Yuki
    Fuji, Haruka
    Tamura, Kazunori
    Nakamura, Nobuo
    Takashima, Kazuma
    Uemura, Keisuke
    Hamada, Hidetoshi
    [J]. BONE & JOINT JOURNAL, 2024, 106B (03): : 104 - 109
  • [10] How to Estimate Femoral Stem Anteversion During Direct Anterior Approach Total Hip Arthroplasty
    Gold, Peter A.
    McCarthy, Thomas F.
    Borukhov, Ilya
    Danoff, Jonathan
    [J]. ARTHROPLASTY TODAY, 2024, 26