Spatial smoothing of autocorrelations to control the degrees of freedom in fMRI analysis

被引:48
|
作者
Worsley, KJ
机构
[1] McGill Univ, Dept Math & Stat, Montreal, PQ H3A 2K6, Canada
[2] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
关键词
fMRI; spatial smoothing; autocorrelations; degrees of freedom;
D O I
10.1016/j.neuroimage.2005.02.007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In the statistical analysis of fMRI data, the parameter of primary interest is the effect of a contrast; of secondary interest is its standard error, and of tertiary interest is the standard error of this standard error, or equivalently, the degrees of freedom (df). In a ReML (Restricted Maximum Likelihood) analysis, we show how spatial smoothing of temporal autocorrelations increases the effective df (but not the smoothness of primary or secondary parameter estimates), so that the amount of smoothing can be chosen in advance to achieve a target df, typically 100. This has already been done at the second level of a hierarchical analysis by smoothing the ratio of random to fixed effects variances (Worsley, K.J., Liao, C., Aston, J.A.D., Petre, V., Duncan, G.H., Morales, F., Evans, A.C., 2002. A general statistical analysis for fMRI data. NeuroImage, 15:1-15); we now show how to do it at the first level, by smoothing autocorrelation parameters. The proposed method is extremely fast and it does not require any image processing. It can be used in conjunction with other regularization methods (Gautama, T., Van Hulle, M.M., in press. Optimal spatial regularisation of autocorrelation estimates in fMRI analysis. NeuroImage.) to avoid unnecessary smoothing beyond 100 df. Our results on a typical 6-min, TR = 3, 1.5-T fMRI data set show that 8.5-mm smoothing is needed to achieve 100 df, and this results in roughly a doubling of detected activations. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 50 条
  • [1] Dimensionality and degrees of freedom in fmri data analysis - A comparative study
    Rydell, J
    Borga, M
    Lundberg, P
    Knutsson, H
    [J]. 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 988 - 991
  • [2] Degrees of freedom analysis for process control
    Rodriguez, M.
    Gayoso, J. A.
    [J]. 16TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING AND 9TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING, 2006, 21 : 1489 - 1494
  • [3] Adaptive spatial smoothing of fMRI images
    Yue, Yu
    Loh, Ji Meng
    Lindquist, Martin A.
    [J]. STATISTICS AND ITS INTERFACE, 2010, 3 (01) : 3 - 13
  • [4] Degrees-of-freedom tests for smoothing splines
    Cantoni, E
    Hastie, T
    [J]. BIOMETRIKA, 2002, 89 (02) : 251 - 263
  • [5] Design and control of spatial inverted pendulum with two degrees of freedom
    Atilla Bayram
    Firat Kara
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [6] Design and control of spatial inverted pendulum with two degrees of freedom
    Bayram, Atilla
    Kara, Firat
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (10)
  • [7] Nonlinear control of structured light in all spatial degrees of freedom
    Wu, Haijun
    Yu, Bingshi
    Jiang, Jiaqi
    Zhao, Bo
    Carmelo, Rosales-Guzmán
    Bai, Zhenxu
    Zhu, Zhihan
    Shi, Baosen
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (08):
  • [8] DEGREES OF FREEDOM ANALYSIS IN-PROCESS CONTROL
    PONTON, JW
    [J]. CHEMICAL ENGINEERING SCIENCE, 1994, 49 (13) : 2089 - 2095
  • [9] OI and fMRI Signal Separation Using Both Temporal and Spatial Autocorrelations
    Li, Ming
    Liu, Yadong
    Feng, Guiyu
    Zhou, Zongtan
    Hu, Dewen
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (08) : 1917 - 1926
  • [10] ESTIMATES OF SPATIAL DEGREES OF FREEDOM
    FRAEDRICH, K
    ZIEHMANN, C
    SIELMANN, F
    [J]. JOURNAL OF CLIMATE, 1995, 8 (02) : 361 - 369