Underestimation of cerebral perfusion on flow-sensitive alternating inversion recovery image: Semiquantitative evaluation with time-to-peak values

被引:3
|
作者
Kim, H. S. [1 ]
Kim, S. Y. [1 ]
Kim, J. M. [1 ]
机构
[1] Ajou Univ, Coll Med, Dept Diagnost Radiol, Suwon 442749, South Korea
关键词
D O I
10.3174/ajnr.A0720
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: We assessed the underestimation of cerebral perfusion measured by the flow-sensitive alternating inversion recovery (FAIR) technique in patients with carotid stenosis and compared the technique with dynamic susceptibility contrast (DSC) MR images. MATERIALS AND METHODS: We studied 42 areas of decreased cerebral blood flow (CBF) using 3 FAIR images with different inversion times (TIs) in 42 consecutive patients with unilateral carotid stenosis of more than 50%. The width of decreased CBF area (wCBF) was qualitatively assessed. We analyzed the ratio of CBF (rCBF) and the time-to-peak (TTP) difference (dTTP) between the ipsilateral hemisphere to carotid stenosis and contralateral normal area using regions of interest (ROIs) at the same location. RESULTS: In the areas with more prolonged TTP (dTTP >= 3.2 s), the wCBF obtained from the FAIR images with TI of 1600 ms was smaller than those from the FAIR images with a TI of 800 ms and 1200 ms in all cases. The mean rCBF obtained from the FAIR images with a TI of 1200 ms was significantly lower than that obtained from the FAIR images with a TI of 1600 ms (P <.01) in the areas with more prolonged TTP. In the areas with less prolonged TTP (dTTP < 3.2 s), the wCBF and mean rCBF were not significantly different between the 2 FAIR images (TI, 1200 and 1600 ms). CONCLUSION: If TTP is delayed significantly (dTTP >= 3.2 s), the FAIR with intermediate or short TI showed underestimation of perfusion in the same area with delay in TTP.
引用
收藏
页码:2008 / 2013
页数:6
相关论文
共 35 条
  • [1] Optimal inversion time for acquiring flow-sensitive alternating inversion recovery images to quantify regional cerebral blood flow
    Arbab, AS
    Aoki, S
    Toyama, K
    Araki, T
    Miyazawa, N
    Kumagai, H
    Umeda, T
    Arai, T
    Okubo, T
    Kabasawa, H
    Takahashi, Y
    EUROPEAN RADIOLOGY, 2002, 12 (12) : 2950 - 2956
  • [2] Optimal inversion time for acquiring flow-sensitive alternating inversion recovery images to quantify regional cerebral blood flow
    Ali Arbab
    Shigeki Aoki
    Keiji Toyama
    Tsutomu Araki
    Nobuhiko Miyazawa
    Hiroshi Kumagai
    Takako Umeda
    Takao Arai
    Toshiyuki Okubo
    Hiroyuki Kabasawa
    Yoshiyuki Takahashi
    European Radiology, 2002, 12 : 2950 - 2956
  • [3] Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR)
    Helpern, JA
    Branch, CA
    Yongbi, MN
    Huang, NC
    MAGNETIC RESONANCE IMAGING, 1997, 15 (02) : 135 - 139
  • [4] Optimization of flow-sensitive alternating inversion recovery (FAIR) for perfusion functional MRI of rodent brain
    Nasrallah, Fatima A.
    Lee, Eugene L. Q.
    Chuang, Kai-Hsiang
    NMR IN BIOMEDICINE, 2012, 25 (11) : 1209 - 1216
  • [5] Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging
    Kim, SG
    Tsekos, NV
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 425 - 435
  • [6] Comparison of perfusion MRI by flow-sensitive alternating inversion recovery and dynamic susceptibility contrast in rats with permanent middle cerebral artery occlusion
    Hofmeijer, J
    Schepers, J
    van der Worp, HB
    Kappelle, LJ
    Nicolay, K
    NMR IN BIOMEDICINE, 2005, 18 (06) : 390 - 394
  • [7] Perfusion imaging of the human lung using Flow-Sensitive Alternating Inversion Recovery with an Extra Radiofrequency pulse (FAIRER)
    Mai, VM
    Hagspiel, KD
    Christopher, JM
    Do, HM
    Altes, T
    Knight-Scott, J
    Stith, AL
    Maier, T
    Berr, SS
    MAGNETIC RESONANCE IMAGING, 1999, 17 (03) : 355 - 361
  • [8] Correlation between flow-sensitive alternating inversion recovery perfusion imaging with different inversion times and cerebral flow reserve evaluated by single-photon-emission computed tomography
    Masafumi Harada
    Masaaki Uno
    Kazuhide Yoneda
    Ayuko Hori
    Hiromu Nishitani
    Tsuyoshi Matsuda
    Neuroradiology, 2004, 46 : 649 - 654
  • [9] Correlation between flow-sensitive alternating inversion recovery perfusion imaging with different inversion times and cerebral flow reserve evaluated by single-photon-emission computed tomography
    Harada, M
    Uno, M
    Yoneda, K
    Hori, A
    Nishitani, H
    Matsuda, T
    NEURORADIOLOGY, 2004, 46 (08) : 649 - 654
  • [10] Non-contrast myocardial perfusion in rest and exercise stress using systolic flow-sensitive alternating inversion recovery
    Henningsson, Markus
    Carlhall, Carl-Johan
    Ebbers, Tino
    Kihlberg, Johan
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (05) : 711 - 718