Autologous Neurosensory Retinal Free Flap Treatment for a Large Macular Hole

被引:3
|
作者
Lazic, Ratimir [1 ]
Draca, Natasa [1 ]
Cerovic, Vesna [1 ]
Katic, Dinko [1 ]
Mladenovski, Stefan [1 ]
Gabric, Nikica [1 ]
机构
[1] Univ Eye Hosp Svjetlost, Retina Dept, Zagreb, Croatia
来源
关键词
INTERNAL LIMITING MEMBRANE; HIGH MYOPIA; TRANSPLANTATION; DETACHMENT; VITRECTOMY;
D O I
10.3928/23258160-20180907-13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A patient presented with a large chronic macular hole (MH) of 700 mu m. Best-corrected visual acuity (BCVA) was 20/200. Since the. MHs edges were attached and stiff, an autologous neurosensory retinal flap was harvested and placed into the MH to close it. Perfluoro-n-octane heavy liquid (PFC) was instilled over the flap and exchanged with silicone oil (1,000 cs). Seven days postoperatively, the MH was closed, with a BCVA of 20/80 that improved to 20/60 at months 1 and 3. Optical coherence tomography and angiography showed patch incorporation with fovea formation and normal circulation.
引用
收藏
页码:E89 / E92
页数:4
相关论文
共 50 条
  • [1] MANAGEMENT OF REFRACTORY LARGE MACULAR HOLE WITH AUTOLOGOUS NEUROSENSORY RETINAL FREE FLAP TRANSPLANTATION
    Chang, Yo-Chen
    Liu, Pei-Kang
    Kao, Tzu-En
    Chen, Kuo-Jen
    Chen, Yi-Hsien
    Chiu, Wei-Jun
    Wu, Kwou-Yeung
    Wu, Wen-Chuan
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (11): : 2134 - 2139
  • [2] Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap
    Neves, Filipe Sousa
    Braga, Joana
    Sepulveda, Paula
    Bilhoto, Miguel
    CASE REPORTS IN OPHTHALMOLOGY, 2019, 10 (02): : 160 - 164
  • [3] AUTOLOGOUS NEUROSENSORY RETINAL FLAP FOR CLOSURE OF REFRACTORY MACULAR HOLE IN A PATIENT WITH MACULAR TELANGIECTASIA
    Hewson, Andrew
    McAllister, Andrew
    Reddie, Ian
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 : 138 - 139
  • [4] Autologous neurosensory retinal transplantation for large refractory idiopathic macular hole
    Kenan Sonmez
    International Ophthalmology, 2021, 41 : 1415 - 1425
  • [5] Long-Term Follow-Up of Refractory Large Macular Hole with Autologous Neurosensory Retinal Free Flap Transplantation
    Lee, Po-Yen
    Chang, Yo-Chen
    Liu, Pei-Kang
    Kao, Tzu-En
    Wu, Horng-Jiun
    Chen, Kuo-Jen
    Wu, Kwou-Yeung
    Cheng, Kai-Chun
    Wu, Wen-Chuan
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [6] Autologous neurosensory retinal transplantation for large refractory idiopathic macular hole
    Sonmez, Kenan
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (04) : 1415 - 1425
  • [7] Autologous Neurosensory Retinal Free Flap for Closure of Refractory Myopic Macular Holes
    Grewal, Dilraj S.
    Mahmoud, Tamer H.
    JAMA OPHTHALMOLOGY, 2016, 134 (02) : 229 - 230
  • [8] Management of refractory macular hole with blood and gas-assisted autologous neurosensory retinal free flap transplantation: a case report
    Pei-Kang Liu
    Yo-Chen Chang
    Wen-Chuan Wu
    BMC Ophthalmology, 18
  • [9] Management of refractory macular hole with blood and gas-assisted autologous neurosensory retinal free flap transplantation: a case report
    Liu, Pei-Kang
    Chang, Yo-Chen
    Wu, Wen-Chuan
    BMC OPHTHALMOLOGY, 2018, 18
  • [10] Autologous neurosensory retinal free patch transplantation for persistent full-thickness macular hole
    Chiara De Giacinto
    Rossella D’Aloisio
    Gabriella Cirigliano
    Marco Rocco Pastore
    Daniele Tognetto
    International Ophthalmology, 2019, 39 : 1147 - 1150