Deep learning based spectral extrapolation for dual-source, dual-energy x-ray computed tomography

被引:10
|
作者
Clark, Darin P. [1 ]
Schwartz, Fides R. [2 ]
Marin, Daniele [2 ]
Ramirez-Giraldo, Juan C. [3 ]
Badea, Cristian T. [1 ]
机构
[1] Duke Univ, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[3] Siemens Healthineers, CT R&D Collaborat, Cary, NC USA
关键词
data completion; deep learning; dual-energy CT; dual-source CT; CT; SCAN;
D O I
10.1002/mp.14324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Data completion is commonly employed in dual-source, dual-energy computed tomography (CT) when physical or hardware constraints limit the field of view (FoV) covered by one of two imaging chains. Practically, dual-energy data completion is accomplished by estimating missing projection data based on the imaging chain with the full FoV and then by appropriately truncating the analytical reconstruction of the data with the smaller FoV. While this approach works well in many clinical applications, there are applications which would benefit from spectral contrast estimates over the larger FoV (spectral extrapolation)-e.g. model-based iterative reconstruction, contrast-enhanced abdominal imaging of large patients, interior tomography, and combined temporal and spectral imaging. Methods To document the fidelity of spectral extrapolation and to prototype a deep learning algorithm to perform it, we assembled a data set of 50 dual-source, dual-energy abdominal x-ray CT scans (acquired at Duke University Medical Center with 5 SiemensFlashscanners; chain A: 50 cm FoV, 100 kV; chain B: 33 cm FoV, 140 kV + Sn; helical pitch: 0.8). Data sets were reconstructed usingReconCT(v14.1, Siemens Healthineers): 768 x 768 pixels per slice, 50 cm FoV, 0.75 mm slice thickness, "Dual-Energy - WFBP" reconstruction mode with dual-source data completion. A hybrid architecture consisting of a learned piecewise linear transfer function (PLTF) and a convolutional neural network (CNN) was trained using 40 scans (five scans reserved for validation, five for testing). The PLTF learned to map chain A spectral contrast to chain B spectral contrast voxel-wise, performing an image domain analog of dual-source data completion with approximate spectral reweighting. The CNN with its U-net structure then learned to improve the accuracy of chain B contrast estimates by copying chain A structural information, by encoding prior chain A, chain B contrast relationships, and by generalizing feature-contrast associations. Training was supervised, using data from within the 33-cm chain B FoV to optimize and assess network performance. Results Extrapolation performance on the testing data confirmed our network's robustness and ability to generalize to unseen data from different patients, yielding maximum extrapolation errors of 26 HU following the PLTF and 7.5 HU following the CNN (averaged per target organ). Degradation of network performance when applied to a geometrically simple phantom confirmed our method's reliance on feature-contrast relationships in correctly inferring spectral contrast. Integrating our image domain spectral extrapolation network into a standard dual-source, dual-energy processing pipeline for SiemensFlashscanner data yielded spectral CT data with adequate fidelity for the generation of both 50 keV monochromatic images and material decomposition images over a 30-cm FoV for chain B when only 20 cm of chain B data were available for spectral extrapolation. Conclusions Even with a moderate amount of training data, deep learning methods are capable of robustly inferring spectral contrast from feature-contrast relationships in spectral CT data, leading to spectral extrapolation performance well beyond what may be expected at face value. Future work reconciling spectral extrapolation results with original projection data is expected to further improve results in outlying and pathological cases.
引用
收藏
页码:4150 / 4163
页数:14
相关论文
共 50 条
  • [1] Unsupervised deep learning based image outpainting for dual-source, dual-energy computed tomography
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [2] Features of dual-energy X-ray computed tomography
    Torikoshi, M
    Tsunoo, T
    Ohno, Y
    Endo, M
    Natsuhori, M
    Kakizaki, T
    Ito, N
    Uesugi, K
    Yagi, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 99 - 105
  • [3] Experimental feasibility of dual-energy computed tomography based on the Thomson scattering X-ray source
    Chi, Zhijun
    Du, Yingchao
    Yan, Lixin
    Wang, Dong
    Zhang, Hongze
    Huang, Wenhui
    Tang, Chuanxiang
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1797 - 1802
  • [4] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Satoshi Okayama
    Ayako Seno
    Tsunenari Soeda
    Yasuhiro Takami
    Rika Kawakami
    Satoshi Somekawa
    Ken-ichi Ishigami
    Yukiji Takeda
    Hiroyuki Kawata
    Manabu Horii
    Shiro Uemura
    Yoshihiko Saito
    The International Journal of Cardiovascular Imaging, 2012, 28 : 901 - 909
  • [5] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 901 - 909
  • [6] X-Ray Spectra Optimization for Dual-Energy Imaging Using Dual-Source CT
    Giraldo, J. Ramirez
    Primak, A.
    Liu, X.
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [7] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [8] Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography
    Sato, Kazuhiro
    Kageyama, Ryota
    Sawatani, Yuta
    Takano, Hirokazu
    Kayano, Shingo
    Takane, Yumi
    Saito, Haruo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (01) : 103 - 116
  • [9] Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography
    Kazuhiro Sato
    Ryota Kageyama
    Yuta Sawatani
    Hirokazu Takano
    Shingo Kayano
    Yumi Takane
    Haruo Saito
    Physical and Engineering Sciences in Medicine, 2021, 44 : 103 - 116
  • [10] Dual-source dual-energy computed tomography angiography for active gastrointestinal bleeding: A preliminary study
    Sun, H.
    Xue, H. -D.
    Wang, Y. -N.
    Qian, J. -M.
    Yu, J. -C.
    Zhu, F.
    Zhu, H. -D.
    Jin, Z. -Y.
    Li, X. -G.
    CLINICAL RADIOLOGY, 2013, 68 (02) : 139 - 147