Evaluation of several solid phase extraction liquid chromatography/tandem mass spectrometry on-line configurations for high-throughput analysis of acidic and basic drugs in rat plasma

被引:29
|
作者
Mallet, CR [1 ]
Mazzeo, JR [1 ]
Neue, U [1 ]
机构
[1] Waters Corp, Milford, MA 01757 USA
关键词
D O I
10.1002/rcm.346
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several configurations using 6- and 10-port switching valves were studied for high flow, on-line extraction of rat plasma coupled to an electrospray triple quadrupole mass spectrometer. Each plasma sample was diluted 1:1 with an aqueous internal standard solution. The sample was injected into a 2.1 x 20 mm cartridge column packed with 25 mum divinylbenzene/N-vinylpyrrolidone packing using 100% aqueous mobile phase at 4 mL/min. After sample loading and sample cleanup, the analytes were eluted from the extraction column with a 1.0-min gradient at 0.4 mL/min. The samples were either analyzed directly after elution from the extraction column or after additional separation using a short high performance liquid chromatography (HPLC) column. The different configurations were tested using an acidic drug (diflunisal) and a basic drug (clemastine) in rat plasma. On-line analysis was performed by injecting 200 muL of diluted plasma. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration standards gave relative standard deviations (RSDs) below 5%. The total time per sample was 3 min. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1075 / 1083
页数:9
相关论文
共 50 条
  • [1] High-throughput analysis of testosterone in serum samples by on-line solid phase extraction liquid chromatography-tandem mass spectrometry
    Savolainen, Kari
    Kiimamaa, Raisa
    Halonen, Toivo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (11) : 1845 - 1848
  • [2] High-throughput on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of 14 antidepressants and their metabolites in plasma
    de Castro, Ana
    Femandez, Maria Del Mar Ramirez
    Laloup, Marleen
    Samyn, Nele
    De Boeck, Gert
    Wood, Michelle
    Maes, Viviane
    Lopez-Rivadulla, Manuel
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) : 3 - 12
  • [3] ON-LINE SOLID PHASE EXTRACTION COUPLED WITH LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY FOR THE DETERMINATION OF CODEINE IN HUMAN PLASMA
    Cruz, Alessandro de C.
    Suenaga, Eunice M.
    Abib, Eduardo
    Pedrazzoli, Jose
    QUIMICA NOVA, 2017, 40 (01): : 25 - 29
  • [4] Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
    Kwok, W. H.
    Leung, David K. K.
    Leung, Gary N. W.
    Wan, Terence S. M.
    Wong, Colton H. F.
    Wong, Jenny K. Y.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (19) : 3289 - 3296
  • [5] An on-line solid phase extraction—Liquid chromatography—Tandem mass spectrometry method for the analysis of citalopram, fluvoxamine, and paroxetine in human plasma
    M. Kollroser
    C. Schober
    Chromatographia, 2003, 57 : 133 - 138
  • [6] An on-line solid phase extraction - Liquid chromatography - Tandem mass spectrometry method for the analysis of citalopram, fluvoxamine, and paroxetine in human plasma
    Kollroser, M
    Schober, C
    CHROMATOGRAPHIA, 2003, 57 (3-4) : 133 - 138
  • [7] Analysis of a basic drug by on-line solid-phase extraction liquid chromatography/tandem mass spectrometry using a mixed mode sorbent
    Mallet, CR
    Lu, ZL
    Mazzeo, J
    Neue, U
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (08) : 805 - 813
  • [8] Analysis of bisphenols in soft drinks by on-line solid phase extraction fast liquid chromatography tandem mass spectrometry
    Gallart-Ayala, H.
    Moyano, E.
    Galceran, M. T.
    ANALYTICA CHIMICA ACTA, 2011, 683 (02) : 227 - 233
  • [9] Measurement of plasma free metanephrines using on-line solid phase extraction high performance liquid chromatography tandem mass spectrometry.
    Graham, K. S.
    van der Cooper, J.
    Cooper, D. P.
    Morris, M. R.
    Kema, I. P.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A90 - A90
  • [10] High-throughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry
    Zhou, SL
    Zhou, HY
    Larson, M
    Miller, DL
    Mao, DM
    Jiang, XY
    Weng, ND
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (15) : 2144 - 2150