Negative Corona Inception Voltages in Rod-plane Gaps at Various Air Pressures and Humidities

被引:58
|
作者
Bian, Xingming [1 ,2 ]
Meng, Xiaobo [1 ,2 ]
Wang, Liming [2 ]
MacAlpine, J. M. K. [2 ]
Guan, Zhicheng [1 ,2 ]
Hui, Jianfeng [3 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ Shenzhen, Grad Sch Shenzhen, Lab Adv Technol Elect Engn & Energy, Shenzhen 518055, Guangdong, Peoples R China
[3] Shanxi Elect Power Corp, Xian 710047, Shanxi Province, Peoples R China
基金
中国国家自然科学基金;
关键词
Negative corona; corona inception voltage; positive corona; pressure; humidity; POINT/CUP ELECTRODE SYSTEM; ONSET VOLTAGE; STRANDED CONDUCTORS; POSITIVE CORONA; FIELDS; PRECIPITATORS; TEMPERATURE; MECHANISM; IMPULSE;
D O I
10.1109/TDEI.2011.5739468
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The variation of negative dc corona inception voltages with air pressure and humidity, using a point/plane electrode system, was studied using a perspex chamber in which the pressure and humidity could be varied. A method of calculation was developed to determine the corona inception voltages over a range of air pressures and humidities. The effective ionization coefficient was calculated as a linear interpolation of the effective ionization coefficients for dry air and water vapor. The validity of these calculations was confirmed by a series of experimental determinations of the corona inception voltages for the same range of pressures and humidities. A comparison of the negative and positive corona inception mechanisms was also made. Both the negative and positive corona inception voltages decreased with a decrease in the air pressure and an increase in the humidity. The greater values of the effective ionization intensity found in the critical zone for the negative corona accounted for their lower inception voltages. The mechanisms of the affect of the photo-absorption coefficient and Townsend's second coefficient on the negative and positive corona were also considered.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 50 条
  • [1] Positive Corona Inception Voltages and Corona Currents for Air at Various Pressures and Humidities
    Bian, Xingming
    Wang, Liming
    MacAlpine, J. M. K.
    Guan, Zhicheng
    Hui, Jianfeng
    Chen, Yong
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) : 63 - 70
  • [2] Impulse Corona Inception in Dielectric Covered Rod-Plane Air Gaps
    Mavroidis, P. N.
    Mikropoulos, P. N.
    Stassinopoulos, C. A.
    [J]. UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 317 - 320
  • [3] Determination of Corona Inception Voltages of Rod-Plane Electrode Systems
    Ilhan, Suat
    Font, Aytug
    Ozdemir, Aydogan
    Espino-Cortes, Fermin
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [4] The Role of Space Charge on Corona Inception Threshold Conditions in Rod-Plane Air Gaps at DC/AC Combined Voltages
    He, Xuyuan
    Zhou, Yunbo
    He, Zichen
    Zhu, Jie
    Zhao, Luxing
    Shen, Boyang
    Bian, Xingming
    [J]. IEEE ACCESS, 2021, 9 : 125496 - 125507
  • [5] Corona Inception and Breakdown Voltages of Rod-Plane Electrode for Severe Ambient Conditions
    Gharaaghaji, Shayan Shahi
    Fadil, Hamza
    Ilhan, Suat
    Ozdemir, Aydogan
    Ismailoglu, Hasbi
    Espino Cortes, Fermin
    [J]. 2019 IEEE MILAN POWERTECH, 2019,
  • [6] Computation of inception voltage and inception time of positive impulse corona in rod-plane gaps
    Abdel-Salam, M.
    Allen, N. L.
    Cotton, I.
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2007, 1 (04) : 179 - 184
  • [7] Streamer Inception and Propagation for Air Insulated Rod-Plane Gaps with Barriers
    Mauseth, F.
    Jorstad, J. S.
    Pedersen, A.
    [J]. 2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 729 - 732
  • [8] A Criterion for UV Detection of AC Corona Inception in a Rod-plane Air Gap
    Zhou, Wenjun
    Li, Han
    Yi, Xiao
    Tu, Jun
    Yu, Jianhui
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (01) : 232 - 237
  • [9] Experimental Analysis on Corona Inception Voltage of Rod-Plane Air Gaps under DC and AC Composite Voltage
    [J]. Zhang, Jinglan (haha830830@126.com), 1600, China Machine Press (32):
  • [10] Corona inception in the presence of insulators in a rod-plane gap under positive switching impulse voltages
    Lazaridis, L. A.
    Mikropoulos, P. N.
    Stassinopoulos, C. A.
    Kerasaridis, C. D.
    Lisaridis, I. G.
    [J]. PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 912 - +