Safety and Diagnostic Accuracy of Percutaneous Ultrasound-Guided Biopsy of the Spleen: A Multicenter Study

被引:39
|
作者
Gomez-Rubio, Mariano [1 ]
Lopez-Cano, Antonio [2 ]
Rendon, Paloma [3 ]
Munoz-Benvenuty, Agustin [4 ]
Macias, Manuel [3 ]
Garre, Carmen [5 ]
Maria Segura-Cabral, Jose [6 ]
机构
[1] Getafe Univ Hosp, Dept Gastroenterol, Madrid 28905, Spain
[2] Astarte Clin, Gastroenterol Ultrasonog & Endoscopy Unit, Cadiz 11011, Spain
[3] Puerta de Mar Univ Hosp, Dept Gastroenterol, Cadiz 11009, Spain
[4] San Raffaele Clin, Diagnost & Therapeut Gastroenterol Unit, Cadiz 11002, Spain
[5] Virgen de la Arrixaca Univ Hosp, Dept Gastroenterol, El Palmar Murcia 30120, Spain
[6] La Paz Univ Hosp, Dept Gastroenterol, Madrid 28046, Spain
关键词
spleen; biopsy; ultrasonography; fine-needle aspiration; core-needle biopsy; NEEDLE-ASPIRATION BIOPSY; CORE BIOPSY; SPLENIC LESIONS; EXPERIENCE;
D O I
10.1002/jcu.20608
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To analyze the safety and accuracy of ultrasound-guided (USG) percutaneous needle biopsy of the spleen. Methods. Sixty-two USG needle biopsies performed in 52 patients were retrospectively analyzed: there were 53 biopsies of local lesions and 9 biopsies of diffuse lesions. Fine-needle aspiration (FNA) was performed in 37 cases and core-needle biopsy (CNB) in 25 cases. The complications and diagnostic accuracy of the 2 types of biopsy were compared. Results. Two patients (3.8%) had postprocedural hemorrhage after CNB; one was minor, and the other severe, requiring splenectomy. No bleeding occurred with FNA. The diagnostic accuracy was similar with FNA (86.5%) and CNB (92%), whereas in patients with lymphoma, accuracy of FNA (80%) tended to be lower than that of CNB (100%), although the difference was not statistically significant. Conclusion. USG needle biopsy is safe and effective for diagnosing both focal and diffuse splenic lesions. The risk of bleeding may be lower with FNA than with CNB. (C) 2009 Wiley Periodicals, Inc. J Clin Ultrasound 37:445-450, 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/jcu.20608
引用
收藏
页码:445 / 450
页数:6
相关论文
共 50 条
  • [1] Intravascular Ultrasound-Guided Transvenous Biopsy of Retroperitoneal Lymph Nodes: Diagnostic Accuracy and Safety Compared with CT-Guided Percutaneous Biopsy
    Buchholz, Joseph
    Cline, Brendan C.
    Martin, Jonathan G.
    Kim, Charles Y.
    Ronald, James
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (04) : 710 - 715
  • [2] Ultrasound-guided biopsy of the pancreas:: A multicenter study
    Garre Sanchez, M. C.
    Rendon Unceta, P.
    Lopez Cano, A.
    Gomez Rubio, M.
    de Cuenca Moron, B.
    Segura Cabral, J. M.
    Crespo Sanchez, M.
    Gil Grande, L. A.
    Varas Lorenzo, M. J.
    Just Timoneda, J.
    Gomez Rodriguez, R.
    Galcera Tomas, J.
    Abraldes Bechiarelli, A.
    Macias Rodriguez, M.
    Munoz Benvenuty, A.
    Tejada Cabrera, M.
    Olveira, A.
    Palacios Lazaro, E.
    [J]. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2007, 99 (09) : 520 - 524
  • [3] ULTRASOUND-GUIDED PERCUTANEOUS NEEDLE BIOPSY FOR PERIPHERAL PULMONARY LESIONS: DIAGNOSTIC ACCURACY AND INFLUENCING FACTORS
    Guo, Yu-Qing
    Liao, Xin-Hong
    Li, Zhi-Xian
    Chen, Yuan-Yuan
    Wang, Si-Da
    Wang, Ji-Han
    Liao, Xian-Shan
    Luo, Yuan
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (05): : 1003 - 1011
  • [4] Effectiveness and safety of ultrasound-guided percutaneous liver biopsy in children
    Hugo Matos
    Maria José Noruegas
    Isabel Gonçalves
    Conceição Sanches
    [J]. Pediatric Radiology, 2012, 42 : 1322 - 1325
  • [5] Effectiveness and safety of ultrasound-guided percutaneous liver biopsy in children
    Matos, Hugo
    Noruegas, Maria Jose
    Goncalves, Isabel
    Sanches, Conceicao
    [J]. PEDIATRIC RADIOLOGY, 2012, 42 (11) : 1322 - 1325
  • [6] Safety and Accuracy of Percutaneous Image-Guided Core Biopsy of the Spleen
    Olson, Michael C.
    Atwell, Thomas D.
    Harmsen, William Scott
    Konrad, Aaron
    King, Rebecca L.
    Lin, Yi
    Wall, Darci J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (03) : 655 - 659
  • [7] ULTRASOUND-GUIDED ALLOGRAFT PANCREAS BIOPSY: SAFETY AND DIAGNOSTIC USE
    Turner, Samuel
    Yeung, Kai Tai
    Moser, Steven
    Cook, Terry
    Roufosse, Candice
    Charif, Rawya
    Mclean, Adam
    Taube, David
    Tait, Paul
    Muthusamy, Anand
    [J]. TRANSPLANT INTERNATIONAL, 2017, 30 : 141 - 141
  • [8] Ultrasound-Guided Percutaneous Breast Biopsy
    Newell, Mary S.
    Mahoney, Mary C.
    [J]. TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 17 (01) : 23 - 31
  • [9] Percutaneous Ultrasound-Guided Biopsy of Pancreas Allograft: It Is Both Safe and Diagnostic
    Stephens, M.
    Witherspoon, J.
    Ilham, A.
    Griffiths, D.
    Yong, A.
    Martin, D.
    Asderakis, A.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 262 - 262
  • [10] PERCUTANEOUS ULTRASOUND-GUIDED BIOPSY OF PANCREAS ALLOGRAFT: IT IS SAFE, ESSENTIAL AND DIAGNOSTIC
    Stephens, Michael
    Witherspoon, Jolene
    Ilham, Adel
    Griffiths, David
    Asderakis, Argiris
    [J]. TRANSPLANT INTERNATIONAL, 2011, 24 : 123 - 123