Experimental study on the heat transfer performance of freeze-dryer's cold trap

被引:0
|
作者
Deng, DQ [1 ]
Xu, L [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The factors affecting the performance of the cold trap are studied in the paper. The primary factors affecting the heat transfer performance of cold trap are vacuum, temperature of the cold trap coil and frost thickness. Research results reveal that the cold trap capacity of capturing vapor increases with the decrease of the temperature of cold trap, the overall heat transfer coefficient of the cold trap decreases with the increase of frost accumulation on the surface of the cold trap coil, and the heat transfer decrease with the increase of the vacuum of cold trap.
引用
收藏
页码:493 / 496
页数:4
相关论文
共 50 条
  • [1] Exergy analysis on a cascade heat pump system in application to freeze-dryer
    Liu, YZ
    Chen, SH
    Shen, RJ
    Feng, X
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 472 - 477
  • [2] A novel atmospheric freeze-dryer using vortex tube and multimode heat input: simulation and experiments
    Rahman, S. M. A.
    Mujumdar, Arun S.
    [J]. ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2008, 3 (04) : 408 - 416
  • [3] Experimental study on heat transfer coefficient in a rotary tube dryer
    Wu, Jing
    Li, Xuanyou
    Wang, Hongyao
    Shi, Yongchun
    Chai, Benyin
    [J]. ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2011, 6 (02): : 312 - 315
  • [4] D. Heat transfer coefficient in the shelves of a freeze dryer
    Bokalot, C
    Nyfeler, P
    [J]. CHIMIA, 2004, 58 (09) : 655 - 657
  • [5] Lyophilization cycle design for highly concentrated protein formulations supported by micro freeze-dryer and heat flux sensor
    Carfagna, Marco
    Rosa, Monica
    Hawe, Andrea
    Friess, Wolfgang
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 643
  • [6] Design and Experimental Optimization of Freeze Thaw Heat Pump Dryer
    Wang J.
    Song W.
    Wang M.
    Wu J.
    Li F.
    Ding T.
    [J]. Journal of Chinese Institute of Food Science and Technology, 2019, 19 (07) : 175 - 183
  • [7] Experimental study of heat and mass transfer in a fixed-bed dryer
    Nassari, Hani
    Azimi, Alireza
    [J]. BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2018, 8 (02): : 3120 - 3125
  • [8] EXPERIMENTAL STUDY OF OPTIMAL FEEDBACK CONTROL OF A FREEZE DRYER
    MEO, D
    FRIEDLY, JC
    [J]. JOURNAL OF FOOD SCIENCE, 1973, 38 (05) : 826 - 830
  • [9] Experimental Study on the Drying Performance of the High Temperature Heat Pump Dryer
    Zhu, Xingwang
    Hu, Chunxia
    Guo, Zhimin
    Su, Yugui
    [J]. ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 3219 - +
  • [10] Experimental study of heat transfer performance on newly-designed heat pipe cold plate equipment
    Ma, Zhe-Shu
    Yao, Shou-Guang
    Ming, Xiao
    [J]. Nanjing Hangkong Hangtian Daxue Xuebao/Journal of Nanjing University of Aeronautics and Astronautics, 2004, 36 (02): : 169 - 173