摘要
Control charts are widely used for monitoring quality characteristics of high-yield processes. In such processes where a large number of zero observations exists in count data, the zero-inflated binomial (ZIB) models are more appropriate than the ordinary binomial models. In ZIB models, random shocks occur with probability theta, and upon the occurrence of random shocks, the number of non-conforming items in a sample of size n follows the binomial distribution with proportion p. In the present article, we study in more detail the exponentially weighted moving average control chart based on ZIB distribution (ZIB-EWMA) and we also propose a new control chart based on the double exponentially weighted moving average statistic for monitoring ZIB data (ZIB-DEWMA). The two control charts are studied in detecting upward shifts in theta or p individually, as well as in both parameters simultaneously. Through a simulation study, we compare the performance of the proposed chart with the ZIB-Shewhart, ZIB-EWMA and ZIB-CUSUM charts. Finally, an illustrative example is also presented to display the practical application of the ZIB charts.
引用
收藏
页码:1319 / 1338
页数:20
相关论文
共 50 条
  • [1] Monitoring of zero-inflated Poisson processes with EWMA and DEWMA control charts
    Alevizakos, Vasileios
    Koukouvinos, Christos
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2020, 36 (01) : 88 - 111
  • [2] CUSUM Control Charts for the Monitoring of Zero-inflated Binomial Processes
    Rakitzis, Athanasios C.
    Maravelakis, Petros E.
    Castagliola, Philippe
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2016, 32 (02) : 465 - 483
  • [3] An adaptive EWMA control chart for monitoring zero-inflated Poisson processes
    Aly, Aya A.
    Saleh, Nesma A.
    Mahmoud, Mahmoud A.
    [J]. COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2022, 51 (04) : 1564 - 1577
  • [4] A Comparative Study of Control Charts for Zero-Inflated Binomial Processes
    Rakitzis, Athanasios C.
    Maravelakis, Petros E.
    Castagliola, Philippe C.
    [J]. 2014 NINTH INTERNATIONAL CONFERENCE ON AVAILABILITY, RELIABILITY AND SECURITY (ARES), 2015, : 420 - 425
  • [5] Economic design of zero-inflated Poisson control chart for monitoring high quality processes
    [J]. Koo, Tong-Yuan (kooty@yuntech.edu.tw), 1600, Chinese Society for Quality (24):
  • [6] Control Charts for Zero-Inflated Binomial Models
    Yawsaeng, Bunpen
    Mayureesawan, Tidadeaw
    [J]. THAILAND STATISTICIAN, 2012, 10 (01): : 107 - 120
  • [7] A double generally weighted moving average control chart for monitoring zero-inflated Poisson processes
    Alevizakos, Vasileios
    Chatterjee, Kashinath
    Koukouvinos, Christos
    [J]. COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2024,
  • [8] A GLR Chart for Monitoring a Zero-Inflated Poisson Process
    Choi, Mi Lim
    Lee, Jaeheon
    [J]. KOREAN JOURNAL OF APPLIED STATISTICS, 2014, 27 (02) : 345 - 355
  • [9] Control Charts for Monitoring the Zero-Inflated Generalized Poisson Processes
    Katemee, Narunchara
    Mayureesawan, Tidadeaw
    [J]. THAI JOURNAL OF MATHEMATICS, 2013, 11 (01): : 237 - 249
  • [10] A generally weighted moving average control chart for zero-inflated Poisson processes
    Alevizakos, Vasileios
    Koukouvinos, Christos
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2020, 36 (02) : 675 - 704