Accuracy of Three Software Applications for Breast Volume Calculations from Three-Dimensional Surface Images

被引:28
|
作者
Wesselius, Tycho S.
Verhulst, Arico C.
Vreeken, Rinaldo D.
Xi, Tong
Maal, Thomas J. J.
Ulrich, Dietmar J. O.
机构
[1] Radboud Univ Nijmegen, Dept Plast Reconstruct & Hand Surg, Med Ctr, Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Dept Oral & Maxillofacial Surg, Med Ctr, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, 3D Lab Radboudumc, Med Ctr, Nijmegen, Netherlands
来源
PLASTIC AND RECONSTRUCTIVE SURGERY | 2018年 / 142卷 / 04期
关键词
FACTORS DETERMINING SHAPE; IMAGING-SYSTEM; REPRODUCIBILITY; SYMMETRY;
D O I
10.1097/PRS.0000000000004728
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Knowing breast volumes before certain surgeries helps the surgeon to obtain breast symmetry. Calculating breast volumes from three-dimensional surface images is possible with specialized software applications. However, limited data exist concerning the accuracy of such volume calculations. The purpose of this study was to investigate the accuracy of breast volume calculations performed with the 3D BreAST, 3dMD Vultus, and VECTRA software applications. Methods: Twenty-six subjects who underwent 44 mastectomies were enrolled. Preoperative three-dimensional surface images were acquired with a VECTRA-XT stereophotogrammetry device. Breast volumes were calculated from these images with the three software applications. The mastectomy specimens were weighed to derive their actual volume and compared with the software calculations. Results: For all three methods, a positive correlation between the breast volume and absolute calculation error was found (p < 0.001), but not for the errors as a percentage of the breast volume (p = 0.17, p = 0.80, and p = 0.42). The 3D BreAST, 3dMD Vultus, and VECTRA applications provided mean volume calculation errors of 21, 186, and -32 ml (p = 0.27, p < 0.001, and p = 0.14) or 2 +/- 25, 48 +/- 26, and -6 +/- 27 percent of the breast volume (p = 0.67, p < 0.001, and p = 0.16), respectively. Conclusions: Despite that two applications calculated accurate mean breast volumes, all applications showed a high standard deviation in terms of the percentage of the breast volume. Therefore, the usefulness of absolute breast volume calculations from three-dimensional surface images seems limited.
引用
收藏
页码:858 / 865
页数:8
相关论文
共 50 条
  • [1] Three-Dimensional Printing of Intracardiac Defects from Three-Dimensional Echocardiographic Images: Feasibility and Relative Accuracy
    Olivieri, Laura J.
    Krieger, Axel
    Loke, Yue-Hin
    Nath, Dilip S.
    Kim, Peter C. W.
    Sable, Craig A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (04) : 392 - 397
  • [2] Three-dimensional breast volume assessment
    Gouveia, P.
    Monteiro, J. P.
    Oliveira, H. P.
    Cardoso, M. J.
    Cardoso, J. S.
    [J]. EUROPEAN JOURNAL OF CANCER, 2016, 57 : S75 - S75
  • [3] Three-dimensional volume rendering from sector scanning images
    Li, J
    Xu, DG
    Cong, W
    [J]. FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY, 2003, 5253 : 402 - 406
  • [4] Three-dimensional virtual images for security applications
    Dunn, DS
    Krasa, RT
    Jonza, JA
    [J]. OPTICAL SECURITY AND COUNTERFEIT DETERRENCE TECHNIQUES V, 2004, 5310 : 328 - 336
  • [5] Three-dimensional surface detection and motion software
    Soll, DR
    [J]. SCANNING, 1999, 21 (02) : 57 - 57
  • [6] Three-dimensional surface reconstruction from multistatic SAR images
    Rigling, BD
    Moses, RL
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2005, 14 (08) : 1159 - 1171
  • [7] Three-dimensional surface reconstruction from multistatic SAR images
    Rigling, BD
    Moses, RL
    [J]. ALGORITHM FOR SYNTHETIC APERTURE RADAR IMAGERY X, 2003, 5095 : 75 - 85
  • [8] Three-dimensional ultrasound: Accuracy of distance and volume measurements
    Riccabona, M
    Nelson, TR
    Pretorius, DH
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 7 (06) : 429 - 434
  • [9] Accuracy of Three-Dimensional Soft Tissue Prediction in Orthognathic Cases Using Dolphin Three-Dimensional Software
    Elshebiny, Tarek
    Morcos, Sherif
    Mohammad, Abdulaziz
    Quereshy, Faisal
    Valiathan, Manish
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (02) : 525 - 528
  • [10] Accuracy of Three-Dimensional Upper Airway Prediction in Orthognathic Patients Using Dolphin Three-Dimensional Software
    Elshebiny, Tarek
    Bous, Rany
    Withana, Thimanthi
    Morcos, Sherif
    Valiathan, Manish
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (04) : 1098 - 1100