Determination and Evaluation of a Dose-Rate Conversion Coefficient for the Xoft Axxent® Electronic Brachytherapy Source in the Xoft Titanium Cervical Applicator

被引:0
|
作者
Simiele, S. [1 ]
Micka, J. [1 ]
Culberson, W. [1 ]
DeWerd, L. [1 ]
机构
[1] Univ Wisconsin, Madison, WI USA
关键词
D O I
10.1118/1.4926150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3709 / 3709
页数:1
相关论文
共 35 条
  • [1] Dose-Rate Constant Determination of the Xoft Axxent Electronic Brachytherapy Source Using Spectroscopic Methods
    Pike, T.
    Moga, J.
    Davis, S.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [2] Ionization Chamber Measured Dose-Rate Constant of the Xoft Axxent Electronic Brachytherapy Source
    Pike, T.
    Davis, S.
    Micka, J.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] A dosimetric comparison of MammoSite high-dose-rate brachytherapy and Xoft Axxent electronic brachytherapy
    Dickler, Adam
    Kirk, Michael C.
    Seif, Neil
    Griem, Katherine
    Dowlatshahi, Kambiz
    Francescatti, Darius
    Abrams, Ross A.
    [J]. BRACHYTHERAPY, 2007, 6 (02) : 164 - 168
  • [4] Biological Characterization of the Effects of Filtration on the Xoft Axxent® Electronic Brachytherapy Source for Cervical Cancer Applications
    Walter, Autumn E.
    Cosper, Pippa F.
    Nickel, Kwangok P.
    Ramesh, Shrey
    Khan, Ahtesham U.
    DeWerd, Larry A.
    Kimple, Randall J.
    [J]. RADIATION RESEARCH, 2023, 199 (05) : 429 - 438
  • [5] Experimental and Computational Dosimetric Characterization of the Xoft AxxentTM Electronic Brachytherapy Source Within a Titanium Cervical Applicator
    Simiele, S.
    Pike, T.
    Micka, J.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Determination of the RBE of the Xoft Axxent Source for Cervical Cancer Applications
    Walter, A.
    Nickel, K.
    Kimple, R.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [7] Acute toxicity with Xoft Axxent Electronic Brachytherapy (XB) in endometrial or cervical cancer
    Mendez Villamon, A.
    Miranda Burgos, A.
    Gascon Ferrer, M.
    Puertas Valino, M.
    Lozares Cordero, S.
    Gandia Martinez, A.
    Font Gomez, J.
    Tejedor Gutierrez, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S979 - S980
  • [8] Modeling study for optimization of skin dose for partial breast irradiation using Xoft Axxent electronic brachytherapy applicator
    Hepel, Jaroslaw T.
    Hiatt, Jessica R.
    Cardarelli, Gene A.
    Wazer, David E.
    [J]. BRACHYTHERAPY, 2010, 9 (01) : 81 - 85
  • [9] The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator
    Simiele, S.
    Micka, J.
    Culberson, W.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 111 - +
  • [10] Determination of dose enhancement caused by AuNPs with Xoft ® Axxent ® Electronic (eBx ™) and conventional brachytherapy: in vitro study
    Shahhoseini, Elham
    Ramachandran, Prabhakar
    Patterson, William Roy
    Geso, Moshi
    [J]. INTERNATIONAL JOURNAL OF NANOMEDICINE, 2018, 13 : 5733 - 5741