Active Search of Subsurface Lymph Nodes Using Robot-Assisted Electrical Impedance Scanning

被引:0
|
作者
Cheng, Zhuoqi [1 ]
Zeltner, Andreas Sorensen [1 ]
Arsvold, Alex Tinggaard [1 ]
Schwaner, Kim Lindberg [1 ]
Jensen, Pernille Tine [2 ]
Savarimuthu, Thiusius Rajeeth [1 ]
机构
[1] Univ Southern Denmark, Maersk Mc Kinney Moller Inst, SDU Robot Sect, DK-5230 Odense, Denmark
[2] Aarhus Univ Hosp, Dept Obstet & Gynaecol, DK-8200 Aarhus, Denmark
关键词
Active area search; electrical bio-impedance (EBI); lymphadenectomy; robot-assisted electrical impedance scanning (RAEIS); robot-assisted minimally invasive surgery (RMIS); tissue detection; MINIMALLY INVASIVE SURGERY; CANCER; IDENTIFICATION; SENSITIVITY; RISK;
D O I
10.1109/TIM.2022.3147909
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lymphadenectomy is frequently performed for cancer treatment. Since lymph nodes are surrounded by fatty tissues, they are often difficult to detect. In robotic-assisted minimally invasive surgery (RMIS), the difficulty increases because haptic feedback is unavailable. This article presents a novel sensing system to assist surgeons with subsurface lymph node detection. The proposed system uses already existing instruments for measuring tissues' electrical properties. A machine-learning-based classifier is developed to estimate the likelihood of a lymph node being present at the measuring site. In addition, an optimized area search algorithm is integrated to make the sensing procedure autonomous and efficient. The proposed system is built and evaluated through experiments using water tank setups, finite element simulation, and ex vivo tissue phantoms. The results demonstrate the efficacy of the proposed method including high detection precision, recall, and Matthews correlation coefficient (MCC). Besides, the proposed method can greatly reduce the number of sampling points compared with a grid-based search method, leading to a quarter faster for the acquisition time. Given the promising performance and easy implementation, the proposed system can potentially improve the quality of related surgical procedures significantly in the future.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Active Search of Subsurface Lymph Nodes Using Robot-Assisted Electrical Impedance Scanning
    Cheng, Zhuoqi
    Zeltner, Andreas Sorensen
    Arsvold, Alex Tinggaard
    Schwaner, Kim Lindberg
    Jensen, Pernille Tine
    Savarimuthu, Thiusius Rajeeth
    [J]. IEEE Transactions on Instrumentation and Measurement, 2022, 71
  • [2] A novel robot-assisted electrical impedance scanning system for subsurface object detection
    Cheng, Zhuoqi
    Savarimuthu, Thiusius Rajeeth
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (08)
  • [3] Lymph Node Detection Using Robot Assisted Electrical Impedance Scanning and an Artificial Neural Network
    Arsvold, Alex Tinggaard
    Zeltner, Andreas Sorensen
    Cheng, Zhuoqi
    Schwaner, Kim Lindberg
    Jensen, Pernille Tine
    Savarimuthu, Thiusius Rajeeth
    [J]. 2021 INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS (ISMR), 2021,
  • [4] Robot-Assisted Electrical Impedance Scanning system for 2D Electrical Impedance Tomography tissue inspection
    Cheng, Zhuoqi
    Dall'Alba, Diego
    Fiorini, Paolo
    Savarimuthu, Thiusius Rajeeth
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3729 - 3733
  • [5] Electrical impedance scanning of lymph nodes: Initial clinical and technical findings
    Malich, A
    Boehm, T
    Facius, M
    Freesmeyer, M
    Azhari, T
    Werner, B
    Anderson, R
    Kaiser, WA
    [J]. CLINICAL RADIOLOGY, 2002, 57 (07) : 579 - 586
  • [6] Robot assisted electrical impedance scanning for tissue bioimpedance spectroscopy measurement
    Cheng, Zhuoqi
    Dall'Alba, Diego
    Schwaner, Kim Lindberg
    Fiorini, Paolo
    Savarimuthu, Thiusius Rajeeth
    [J]. MEASUREMENT, 2022, 195
  • [7] Analysis of regional lymph nodes in periprostatic fat following robot-assisted radical prostatectomy
    Yuh, Bertram
    Wu, Huiqing
    Ruel, Nora
    Wilson, Timothy
    [J]. BJU INTERNATIONAL, 2012, 109 (04) : 603 - 607
  • [8] Robot-assisted catheter insertion using hybrid impedance control
    Jayender, J.
    Patel, R. V.
    Nikumb, S.
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, : 607 - +
  • [9] Robot-Assisted Optical Ultrasound Scanning
    Dwyer, George
    Alles, Erwin J.
    Colchester, Richard J.
    Iyengar, Keshav
    Desjardins, Adrien E.
    Stoyanov, Danail
    [J]. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (04): : 948 - 958
  • [10] Pathological analysis of lymph nodes in anterior prostatic fat excised at robot-assisted radical prostatectomy
    Aning, J. J.
    Thurairaja, R.
    Gillatt, D. A.
    Koupparis, A. J.
    Rowe, E. W.
    Oxley, J.
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2014, 67 (09) : 787 - 791