Magnetic resonance temperature imaging

被引:148
|
作者
De Senneville, BD
Quesson, B
Moonen, CTW
机构
[1] Univ Bordeaux 2, Lab Mol & Funct Imaging, ERT CNRS, F-33076 Bordeaux, France
[2] Image Guided Therapy, Pessac, France
关键词
magnetic resonance imaging; temperature imaging; thermal therapies; motion artifacts; susceptibility artifacts;
D O I
10.1080/02656730500133785
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Continuous, real-time, 3D temperature mapping during a hyperthermic procedure may provide (i) enhanced safety by visualizing temperature maps in and around the treated region, (ii) improved efficiency by adapting local energy deposition with feedback coupling algorithms and (iii) therapy end-points based on the accumulated thermal dose. Non-invasive mapping of temperature changes can be achieved with MRI and may be based on temperature dependent MRI parameters. The excellent linearity of the temperature dependency of the proton resonance frequency (PRF) and its near-independence with respect to tissue type make the PRF-based methods the preferred choice for many applications, in particular at mid- to-high field strength (>= 0.5 T). The PRF methods employ RF-spoiled gradient echo imaging methods and incorporate fat suppression techniques for most organs. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 s and a spatial resolution of similar to 2 mm is feasible for immobile tissues. Special attention is paid to methods for reducing artifacts in MR temperature mapping caused by intra-scan and inter-scan motion and motion and temperature-induced susceptibility effects in mobile tissues. Real-time image processing and visualization techniques, together with accelerated MRI acquisition techniques, are described because of their potential for therapy guidance.
引用
收藏
页码:515 / 531
页数:17
相关论文
共 50 条
  • [1] Temperature mapping with magnetic resonance imaging
    Feng, Suyun
    Peng, Yuhua
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 604 - 608
  • [2] Fast magnetic-resonance temperature imaging
    deZwart, JA
    vanGelderen, P
    Kelly, DJ
    Moonen, CTW
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 112 (01): : 86 - 90
  • [3] Magnetic resonance temperature imaging for guidance of thermotherapy
    Quesson, B
    de Zwart, JA
    Moonen, CTW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (02) : 525 - 533
  • [4] Magnetic resonance temperature imaging for guidance of thermotherapy
    Quesson, B
    de Zwart, JA
    Moonen, CTW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (04) : 525 - 533
  • [5] Ferromagnetic particles as magnetic resonance imaging temperature sensors
    J. H. Hankiewicz
    Z. Celinski
    K. F. Stupic
    N. R. Anderson
    R. E. Camley
    Nature Communications, 7
  • [6] NUCLEAR-MAGNETIC-RESONANCE IMAGING OF TEMPERATURE PROFILES
    SUITS, BH
    WHITE, D
    JOURNAL OF APPLIED PHYSICS, 1986, 60 (10) : 3772 - 3773
  • [7] Tissue temperature monitoring using magnetic resonance imaging
    Oztoprak, U
    Ozkan, M
    PROCEEDINGS OF THE 1998 2ND INTERNATIONAL CONFERENCE BIOMEDICAL ENGINEERING DAYS, 1998, : 106 - 109
  • [8] Ferromagnetic particles as magnetic resonance imaging temperature sensors
    Hankiewicz, J. H.
    Celinski, Z.
    Stupic, K. F.
    Anderson, N. R.
    Camley, R. E.
    NATURE COMMUNICATIONS, 2016, 7
  • [9] Postmortem Magnetic Resonance Imaging Dealing with Low Temperature Objects
    Kobayashi, Tomoya
    Isobe, Tomonori
    Shiotani, Seiji
    Saito, Hajime
    Saotome, Kousaku
    Kaga, Kazunori
    Miyamoto, Katsumi
    Kikuchi, Kazunori
    Hayakawa, Hideyuki
    Akutsu, Hiroyoshi
    Homma, Kazuhiro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (03) : 101 - 108
  • [10] Glass transition temperature mapping using magnetic resonance imaging
    Ruan, RR
    Long, Z
    Chang, K
    Chen, PL
    Taub, IA
    TRANSACTIONS OF THE ASAE, 1999, 42 (04): : 1055 - 1059