A finite element simulation of the effect of graft stiffness and graft tensioning in ACL reconstruction

被引:85
|
作者
Peña, E [1 ]
Martínez, MA [1 ]
Calvo, B [1 ]
Palanca, D [1 ]
Doblaré, M [1 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res, Grp Struct Mech & Mat Modelling, E-50018 Zaragoza, Spain
关键词
anterior cruciate ligament; knee biomechanics; graft stiffness; graft tensioning; finite element method;
D O I
10.1016/j.clinbiomech.2004.07.014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background The anterior cruciate is the most frequent knee ligament to be totally disrupted. Surgical reconstruction of the anterior cruciate ligament is a common practice to treat the disability or chronical instability of knees due to anterior cruciate ligament insufficiency. Some of the factors that influence the success or failure of the anterior cruciate ligament reconstruction are the integrity of secondary restraints, the preoperative laxity of the knee, the status of the articular and meniscal cartilages, the selection of the graft material, the surgical technique, the graft tension and the postoperative rehabilitation. Methods. In this paper we present and discuss the results obtained with a three-dimensional finite element model of the human knee joint corresponding to different aspects of human anterior cruciate ligament reconstruction. In particular, this model was used to investigate the effect of graft stiffness and graft tensioning on the knee joint biomechanics. The initial graft tension was set to 0, 20, 40 or 60 N with the knee at 0 degrees, 30 degrees and 60 degrees of flexion. Three different stiffnesses corresponding to those of patellar tendon, gracilis and quadrupled semitendinosus grafts were analyzed. Findings. The resulting kinematics in each of these cases under an anterior load of 134 N was compared to that of the intact knee. The obtained results showed that, after reconstruction, the closest anterior tibial translation to that of the intact knee is obtained with a bone-patellar tendon-bone graft with a pretension of 60 N. Interpretation. However, this initial tension produces an important additional stress in the graft during the knee movement. This may cause problems in revascularization and remodelling during the postoperative healing process. A lower pretension of about 40 N should therefore be recommended in the present conditions. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:636 / 644
页数:9
相关论文
共 50 条
  • [1] The effect of graft tensioning in anatomic 2-bundle ACL reconstruction on knee joint kinematics
    Hoshino, Yuichi
    Kuroda, Ryosuke
    Nagamune, Kouki
    Nishimoto, Koji
    Yagi, Masayoshi
    Mizuno, Kiyonori
    Yoshiya, Shinichi
    Kurosaka, Masahiro
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (05) : 508 - 514
  • [2] The effect of graft tensioning in anatomic 2-bundle ACL reconstruction on knee joint kinematics
    Yuichi Hoshino
    Ryosuke Kuroda
    Kouki Nagamune
    Koji Nishimoto
    Masayoshi Yagi
    Kiyonori Mizuno
    Shinichi Yoshiya
    Masahiro Kurosaka
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 508 - 514
  • [3] The effect of graft stiffness on knee joint biomechanics after ACL reconstruction - a 3D computational simulation
    Suggs, J
    Wang, C
    Li, GA
    [J]. CLINICAL BIOMECHANICS, 2003, 18 (01) : 35 - 43
  • [4] Effect of Suturing of a Tendon Graft in ACL Reconstruction
    Chizari, M.
    Wang, B.
    Snow, M.
    [J]. ENGINEERING LETTERS, 2009, 17 (03)
  • [5] Device-assisted tensioning is associated with lower rates of graft failure when compared to manual tensioning in ACL reconstruction
    Laura Morrison
    Chloe Haldane
    Darren de SA
    Fawaz Findakli
    Nicole Simunovic
    Olufemi R. Ayeni
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3690 - 3698
  • [6] Device-assisted tensioning is associated with lower rates of graft failure when compared to manual tensioning in ACL reconstruction
    Morrison, Laura
    Haldane, Chloe
    de Sa, Darren
    Findakli, Fawaz
    Simunovic, Nicole
    Ayeni, Olufemi R.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (12) : 3690 - 3698
  • [7] ACL Graft Position Affects in Situ Graft Force Following ACL Reconstruction
    Araujo, Paulo H.
    Asai, Shigehiro
    Pinto, Mauricio
    Protta, Thiago
    Middleton, Kellie
    Linde-Rosen, Monica
    Irrgang, James
    Smolinski, Patrick
    Fu, Freddie H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (21): : 1767 - 1773
  • [8] Finite Element Analysis of ACL Reconstruction-Compatible Knee Implant Design with Bone Graft Component
    Carpena, Ferdinand Lauren F.
    Tayo, Lemmuel L.
    [J]. COMPUTATION, 2023, 11 (08)
  • [9] Stiffness and shape of the ACL graft affects tunnel enlargement and graft wear
    Huizhi Wang
    Bo Zhang
    Cheng-Kung Cheng
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 2184 - 2193
  • [10] Stiffness and shape of the ACL graft affects tunnel enlargement and graft wear
    Wang, Huizhi
    Zhang, Bo
    Cheng, Cheng-Kung
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (07) : 2184 - 2193