Heart Rate Variability Analysis for Seizure Detection in Neonatal Intensive Care Units

被引:4
|
作者
Olmi, Benedetta [1 ]
Manfredi, Claudia [1 ]
Frassineti, Lorenzo [1 ,2 ]
Dani, Carlo [3 ]
Lori, Silvia [4 ]
Bertini, Giovanna [3 ]
Cossu, Cesarina [4 ]
Bastianelli, Maria [4 ]
Gabbanini, Simonetta [4 ]
Lanata, Antonio [1 ]
机构
[1] Univ Firenze, Dept Informat Engn, Via Santa Marta 3, I-50139 Florence, Italy
[2] Univ Siena, Dept Med Biotechnol, I-53100 Siena, Italy
[3] AOU Careggi, Div Neonatol, Dept Neurosci Psychol Drug Res & Child Hlth, Largo Brambilla 3, I-50134 Florence, Italy
[4] AOU Careggi Univ, Neuromusculoskeletal Dept, Neurophysiol Unit, Largo Brambilla 3, I-50134 Florence, Italy
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 04期
关键词
neonatal seizures; ECG; HRV; multiscale entropy; NICU;
D O I
10.3390/bioengineering9040165
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In Neonatal Intensive Care Units (NICUs), the early detection of neonatal seizures is of utmost importance for a timely clinical intervention. Over the years, several neonatal seizure detection systems were proposed to detect neonatal seizures automatically and speed up seizure diagnosis, most based on the EEG signal analysis. Recently, research has focused on other possible seizure markers, such as electrocardiography (ECG). This work proposes an ECG-based NSD system to investigate the usefulness of heart rate variability (HRV) analysis to detect neonatal seizures in the NICUs. HRV analysis is performed considering time-domain, frequency-domain, entropy and multiscale entropy features. The performance is evaluated on a dataset of ECG signals from 51 full-term babies, 29 seizure-free. The proposed system gives results comparable to those reported in the literature: Area Under the Receiver Operating Characteristic Curve = 62%, Sensitivity = 47%, Specificity = 67%. Moreover, the system's performance is evaluated in a real clinical environment, inevitably affected by several artefacts. To the best of our knowledge, our study proposes for the first time a multi-feature ECG-based NSD system that also offers a comparative analysis between babies suffering from seizures and seizure-free ones.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Time-frequency analysis of heart rate variability for neonatal seizure detection
    Malarvili, M. B.
    Mesbah, Mostefa
    Boashash, Boualem
    [J]. EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2007, 2007 (1)
  • [2] Time-frequency analysis of heart rate variability for neonatal seizure detection
    Signal Processing Research Laboratory, Queensland University of Technology, Brisbane, QLD, Australia
    [J]. Australas. Phys. Eng. Sci. Med, 2006, 1 (67-72):
  • [3] Time-Frequency Analysis of Heart Rate Variability for Neonatal Seizure Detection
    M. B. Malarvili
    Mostefa Mesbah
    Boualem Boashash
    [J]. EURASIP Journal on Advances in Signal Processing, 2007
  • [4] Heart rate variability in intensive care
    Goldstein, B
    Buchman, TG
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 1998, 13 (05) : 252 - 265
  • [5] Time-frequency distribution moments of heart rate variability for neonatal seizure detection
    Malarvili, M. B.
    Mesbah, Mostefa
    Boashash, Boualem
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-13, 2006, : 2600 - 2603
  • [6] Development of a System for the Assessment of Heart Rate Variability in the Neonatal Intensive Care Unit (NICU)
    Schiavenato, Martin
    Oliu, Carlos
    Bello, Edward
    Bohorquez, Jorge
    Claure, Nelson
    [J]. 29TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE (SBEC 2013), 2013, : 25 - +
  • [7] ANALYSIS OF HEART RATE AND HEART RATE VARIABILITY DURING LIVE PEDIATRIC INTENSIVE CARE ACTIVITIES
    Slamon, Nicholas
    Nadkarni, Vinay
    Penfil, Scott
    Parker, Robert
    [J]. CRITICAL CARE MEDICINE, 2018, 46 (01) : 103 - 103
  • [8] Newborn Seizure Detection Based on Heart Rate Variability
    Malarvili, M. B.
    Mesbah, Mostefa
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (11) : 2594 - 2603
  • [9] Variability in the nurse-patient ratio in neonatal intensive care units and intermediate care units
    Fernandez-Tunas, M. C.
    Barrio-Tobio, L.
    Couselo-Garcia, L.
    Perez-Munuzuri, A.
    [J]. ENFERMERIA INTENSIVA, 2020, 31 (01): : 46 - 47
  • [10] Forehead monitoring of heart rate in neonatal intensive care
    Stockwell, S. J.
    Kwok, T. C.
    Morgan, S. P.
    Sharkey, D.
    Hayes-Gill, B. R.
    [J]. FRONTIERS IN PHYSIOLOGY, 2023, 14