Three-dimensional ultrasound for the assessment of breast lesions

被引:51
|
作者
Watermann, DO [1 ]
Földi, M [1 ]
Hanjalic-Beck, A [1 ]
Hasenburg, A [1 ]
Lüghausen, A [1 ]
Prömpeler, H [1 ]
Gitsch, G [1 ]
Stickeler, E [1 ]
机构
[1] Univ Freiburg, Med Ctr, Dept Obstet & Gynecol, D-79106 Freiburg, Germany
关键词
breast neoplasms; breast ultrasound; diagnostic accuracy; three-dimensional ultrasound;
D O I
10.1002/uog.1909
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate the diagnostic accuracy of three-dimensional (3D) ultrasound in comparison with conventional two-dimensional (2D) ultrasound in the characterization of breast lesions. Methods The digitally stored 2D ultrasound images and the corresponding 3D scans of 100 breast lesions (57 malignant, 43 benign) that had been morphologically classified as solid tumors, were independently analyzed by six investigators. Ten 2D and 13 3D ultrasound characteristics were determined. Lesion characterization was classified on a four-point scale and a logistic regression model was used to analyze the data. A receiver-operating characteristics curve (ROC) analysis was performed to determine the diagnostic performance of 2D and 3D ultrasound, respectively. Results Ultrasound criteria showed major differences between 2D and 3D ultrasound. Logistic regression revealed the retraction phenomenon in the coronal plane of the 3D ultrasound scan to be a significant and independent factor for lesion characterization. The characteristics determined on the conventional planes of 3D ultrasound differed from those determined on the 2D ultrasound images. The diagnostic accuracy of 2D and 3D ultrasound in the ROC analysis was almost identical (area under the curve 0.846 and 0.851, respectively). Conclusions Ultrasound features on 3D ultrasound differ significantly from those on 2D ultrasound. However, the diagnostic accuracy of both methods is almost identical. 3D ultrasound as an adjunct to conventional 2D ultrasound should be evaluated in larger trials to determine its clinical value in breast imaging. Copyright (c) 2005 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:592 / 598
页数:7
相关论文
共 50 条
  • [1] Automated quality assessment in three-dimensional breast ultrasound images
    Schwaab, Julia
    Diez, Yago
    Oliver, Arnau
    Marti, Robert
    van Zelst, Jan
    Gubern-Merida, Albert
    Mourri, Ahmed Bensouda
    Gregori, Johannes
    Guenther, Matthias
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (02)
  • [2] Three-dimensional ultrasound and three-dimensional power Doppler in the assessment of ovarian tumors
    Laban, M.
    Metawee, H.
    Elyan, A.
    Kamal, M.
    Kamel, M.
    Mansour, G.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 99 (03) : 201 - 205
  • [3] Three-dimensional breast volume assessment
    Gouveia, P.
    Monteiro, J. P.
    Oliveira, H. P.
    Cardoso, M. J.
    Cardoso, J. S.
    [J]. EUROPEAN JOURNAL OF CANCER, 2016, 57 : S75 - S75
  • [4] Value of three-dimensional ultrasound and MRI in meniscal lesions
    Helwig, P.
    Bahrs, C.
    Weise, K.
    Schewe, B.
    [J]. ORTHOPADE, 2006, 35 (09): : 982 - 988
  • [5] Extended field-of-view and three-dimensional ultrasound imaging of silicone breast implant lesions
    Papadia, A.
    Menada, M. V.
    Ragni, N.
    Brusaca, B.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (03) : 360 - 361
  • [6] Three-dimensional ultrasound-validated large-core needle biopsy: is it a reliable method for the histological assessment of breast lesions?
    Delle Chiaie, L
    Terinde, R
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (04) : 393 - 397
  • [7] Vascular morphologic information of three-dimensional power Doppler ultrasound is valuable in the classification of breast lesions
    Yen, Ping-Lang
    Wu, Hwa-Koon
    Tseng, Hsin-Shun
    Kuo, Shou-Jen
    Huang, Yu-Len
    Chen, Hong-Ting
    Chen, Dar-Ren
    [J]. CLINICAL IMAGING, 2012, 36 (04) : 267 - 271
  • [8] Three-dimensional ultrasound system for guided breast brachytherapy
    De Jean, Paul
    Beaulieu, Luc
    Fenster, Aaron
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5099 - 5106
  • [9] Cumulus assessment by three-dimensional ultrasound for in vitro fertilization
    Poehl, M
    Hohlagschwandtner, M
    Doerner, V
    Dillinger, B
    Feichtinger, W
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (03) : 251 - 253
  • [10] Three-Dimensional Assessment of Scoliosis Based on Ultrasound Data
    Zhang, Junhua
    Li, Hongjian
    Yu, Bo
    [J]. EIGHTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2015), 2015, 9875