Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture

被引:8
|
作者
Kraus, Michal [1 ]
Senitkova, Ingrid Juhasova [1 ]
机构
[1] Inst Technol & Business Ceske Budejovice, Dept Civil Engn, Okruzni 517-10, Ceske Budejovice 37001, Czech Republic
关键词
TIME;
D O I
10.1088/1757-899X/245/4/042068
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users' health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [mu g/m(3)]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [degrees C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10 mu g/m(3) of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Quantitative filter forensics: Size distribution and particulate matter concentrations in residential buildings
    Mahdavi, Alireza
    Siegel, Jeffrey A.
    [J]. INDOOR AIR, 2021, 31 (04) : 1050 - 1060
  • [2] Airborne particulate matter concentration at different heights in a residential building in Singapore
    Gupta, A
    Cheong, KWD
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1748 - 1752
  • [3] APPLICABILITY OF MASS CONCENTRATION STANDARDS FOR PARTICULATE MATTER IN ALASKAN AREAS
    GILMORE, TM
    HANNA, TR
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1975, 25 (05): : 535 - 539
  • [4] Seasonal Variation of Particulate Matter Mass Concentration and Content of Metals
    Majewski, Grzegorz
    Kleniewska, Malgorzata
    Brandyk, Andrzej
    [J]. POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2011, 20 (02): : 417 - 427
  • [5] A new calibration device of particulate matter mass concentration monitor
    Zou, Junchen
    Fan, Wei
    Cui, Yaohua
    Bao, Bing
    Zhou, Wenhui
    Zhou, Xingang
    Lv, Chenglin
    Liu, Jiangtao
    Ma, Zhenqi
    Wang, Yong
    Gai, Guosheng
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON RESOURCE EXPLORATION AND ENVIRONMENTAL SCIENCE (REES 2017), 2017, 64
  • [6] A Study on Indoor/Outdoor Concentration of Particulate Matter in Rural Residential Houses in India
    Massey, David. D.
    Kulshrestha, Aditi
    Taneja, Ajay
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND COMPUTER SCIENCE, 2009, : 218 - +
  • [7] The Determinants of Mass Concentration of Indoor Particulate Matter in a Nursing Home
    Cheng, Tsung-Jung
    Chang, Chih-Yi
    Tsou, Pei-Ni
    Wu, Ming-Ju
    Feng, Yun-Shu
    [J]. FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 3026 - +
  • [8] The determinants of mass concentration of indoor particulate matter in a nursing home
    Cheng, Tsung-Jung
    Chang, Chih-Yi
    Tsou, Pei-Ni
    Wu, Ming-Ju
    Feng, Yun-Shu
    [J]. Applied Mechanics and Materials, 2011, 44-47 : 3026 - 3030
  • [9] Mass, composition, and sources of particulate matter in residential and traffic sites of an urban environment
    N. Manojkumar
    Jithin Jose
    Gowtham Guptha
    Ankur Bhardwaj
    B. Srimuruganandam
    [J]. Environmental Geochemistry and Health, 2023, 45 : 2031 - 2050
  • [10] Mass, composition, and sources of particulate matter in residential and traffic sites of an urban environment
    Manojkumar, N.
    Jose, Jithin
    Guptha, Gowtham
    Bhardwaj, Ankur
    Srimuruganandam, B.
    [J]. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2023, 45 (05) : 2031 - 2050