Bayesian-based Localization of Wireless Capsule Endoscope using Received Signal Strength

被引:0
|
作者
Nadimi, Esmaeil S. [1 ]
Blanes-Vidal, Victoria [1 ]
Tarokh, Vahid
Johansen, Per Michael [1 ]
机构
[1] Univ Southern Denmark, Fac Engn, DK-5230 Odense, Denmark
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In wireless body area sensor networking (WBASN) applications such as gastrointestinal (GI) tract monitoring using wireless video capsule endoscopy (WCE), the performance of out-of-body wireless link propagating through different body media (i.e. blood, fat, muscle and bone) is still under investigation. Most of the localization algorithms are vulnerable to the variations of path-loss coefficient resulting in unreliable location estimation. In this paper, we propose a novel robust probabilistic Bayesian-based approach using received-signal-strength (RSS) measurements that accounts for Rayleigh fading, variable path-loss exponent and uncertainty in location information received from the neighboring nodes and anchors. The results of this study showed that the localization root mean square error of our Bayesian-based method was 1.6 mm which was very close to the optimum Cramer-Rao lower bound (CRLB) and significantly smaller than that of other existing localization approaches (i.e. classical MDS (64.2mm), dwMDS (32.2mm), MLE (36.3mm) and POCS (2.3mm)).
引用
收藏
页码:5988 / 5991
页数:4
相关论文
共 50 条
  • [1] Derivation of CRLB for Wireless Capsule Endoscope Localization Using Received Signal Strength
    Ara, Perzila
    Yu, Kegen
    Cheng, Shaokoon
    Dutkiewicz, Eryk
    Heimlich, Michael C.
    [J]. IEEE SENSORS JOURNAL, 2016, 16 (24) : 9064 - 9074
  • [2] Localization method using received signal strength for wireless power transmission of capsule endoscope
    Hiyoshi, Daijiro
    Takahashi, Masaharu
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP 2017), 2017,
  • [3] Localization Method Using Received Signal Strength for Wireless Power Transmission of the Capsule Endoscope
    Hiyoshi, Daijiro
    Takahashi, Masaharu
    [J]. IEICE TRANSACTIONS ON COMMUNICATIONS, 2019, E102B (08) : 1660 - 1667
  • [4] A Bayesian sampling approach to in-door localization of wireless devices using received signal strength indication
    Seshadri, V
    Záruba, GV
    Huber, M
    [J]. Third IEEE International Conference on Pervasive Computing and Communications, Proceedings, 2005, : 75 - 84
  • [5] Received-Signal-Strength-Based Localization in Wireless Sensor Networks
    Niu, Ruixin
    Vempaty, Aditya
    Varshney, Pramod K.
    [J]. PROCEEDINGS OF THE IEEE, 2018, 106 (07) : 1166 - 1182
  • [6] Wireless Capsule Endoscope Localization Using LSTM Network
    Hany, Umma
    Hye, Nafe Muhtasim
    Akter, Lutfa
    [J]. IEEE SENSORS LETTERS, 2023, 7 (12) : 1 - 4
  • [7] Relative nodes localization in wireless networks using received strength signal variations
    Bouassida, Mohamed Salah
    Shawky, Mohamed
    [J]. WINSYS 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON WIRELESS INFORMATION NETWORKS AND SYSTEMS, 2008, : 195 - 202
  • [8] Received Signal Strength-Based Wireless Localization via Semidefinite Programming
    Ouyang, Robin Wentao
    Wong, Albert Kai-Sun
    Lea, Chin-Tau
    Zhang, Victoria Ying
    [J]. GLOBECOM 2009 - 2009 IEEE GLOBAL TELECOMMUNICATIONS CONFERENCE, VOLS 1-8, 2009, : 4637 - 4642
  • [9] Localization of an ultra wide band wireless endoscopy capsule inside the human body using received signal strength and centroid algorithm
    Suveren, Memduh
    Akay, Rustu
    Kanaan, Muzaffer
    [J]. INTERNATIONAL JOURNAL OF OPTIMIZATION AND CONTROL-THEORIES & APPLICATIONS-IJOCTA, 2022, 12 (02): : 151 - 159
  • [10] Indoor Localization Using Received Signal Strength
    Obeidat, H. A.
    Abd-Alhameed, R. A.
    Noras, J. M.
    Zhu, S.
    Ghazaany, T.
    Ali, N. T.
    Elkhazmi, E.
    [J]. 2013 8TH INTERNATIONAL DESIGN AND TEST SYMPOSIUM (IDT), 2013,