Patient Repositioning Reproducibility of Joint Space Width Measurements on Hand Radiographs

被引:14
|
作者
Neumann, Gesa [1 ]
dePablo, Paola [1 ]
Finckh, Axel [2 ]
Chibnik, Lori B. [1 ]
Wolfe, Fred [3 ]
Duryea, Jeffrey [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[2] Univ Hosp Geneva, Geneva, Switzerland
[3] Natl Data Bank Rheumat Dis, Wichita, KS USA
关键词
RHEUMATOID-ARTHRITIS; ABNORMALITIES; COMPUTER; WRIST;
D O I
10.1002/acr.20374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. Computer-based methods to measure radiographic joint space width (JSW) have the potential to improve the longitudinal assessment of rheumatoid arthritis (RA). The purpose of this report was to measure the long-term patient repositioning reproducibility of software-measured radiographic JSW. Methods. Patients underwent baseline and followup hand radiography examinations with a followup time of <= 3 years. To eliminate any JSW change due to real disease progression, the evaluation was performed on "unaffected" joints, defined as having JSW and erosion Sharp scores of 0 at both baseline and followup. The root mean square SD (RMSSD) and coefficient of variation (CV) were used as the reproducibility metrics. Results. The RMSSD was 0.14 mm (CV 10.5%) for all joints, 0.18 mm (CV 10.9%) for the metacarpophalangeal (MCP) joints, and 0.08 mm (CV 8.3%) for the proximal interphalangeal (PIP) joints. The distribution of JSW change was asymmetric, suggesting that narrowing due to RA progression occurred for several joints. A second analysis was performed, excluding joints where the loss of JSW was greater than 3 SDs. For this analysis, the RMSSD was 0.10 mm (CV 7.5%) for all joints, 0.12 mm (CV 7.3%) for the MCP joints, and 0.07 mm (CV 7.1%) for the PIP joints. Conclusion. Repositioning reproducibility is very good but is likely to be a dominating factor compared to reader and software reproducibility. Additionally, further evidence is given that a software method is able to detect changes in some joints for which the Sharp score is insensitive.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 50 条
  • [1] Reproducibility of software measured joint space width on digital hand radiographs.
    Duryea, J
    Finckh, A
    DePablo, P
    Wolfe, F
    Neumann, G
    [J]. ARTHRITIS AND RHEUMATISM, 2003, 48 (09): : S537 - S537
  • [2] Validation of automatic joint space width measurements in hand radiographs in rheumatoid arthritis
    Schenk, Olga
    Huo, Yinghe
    Vincken, Koen L.
    van de laar, Mart A.
    Kuper, Ina H. H.
    Slump, Kees C. H.
    Lafeber, Floris P. J. G.
    Moens, Hein J. Bernelot
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (04)
  • [3] Hand radiographs preprocessing, image representation in the finger regions and joint space width measurements for image interpretation
    Bielecki, Andrzej
    Korkosz, Mariusz
    Zielinski, Bartosz
    [J]. PATTERN RECOGNITION, 2008, 41 (12) : 3786 - 3798
  • [4] Validity of joint space width measurements in hand osteoarthritis
    Kwok, W. Y.
    Bijsterbosch, J.
    Malm, S. H.
    Biermasz, N. R.
    Huetink, K.
    Nelissen, R. G.
    Meulenbelt, I.
    Huizinga, T. W. J.
    van 't Klooster, R.
    Stoel, B. C.
    Kloppenburg, M.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2011, 19 (11) : 1349 - 1355
  • [5] Field test of the reproducibility of automated measurements of medial tibiofemoral joint space width derived from standardized knee radiographs
    Mazzuca, SA
    Brandt, KD
    Buckland-Wright, JC
    Buckwalter, KA
    Katz, BP
    Lynch, JA
    Ward, RJ
    Emsley, CL
    [J]. JOURNAL OF RHEUMATOLOGY, 1999, 26 (06) : 1359 - 1365
  • [6] INFLUENCE OF BLINDING SEQUENCE OF RADIOGRAPHS ON THE REPRODUCIBILITY OF KNEE JOINT SPACE WIDTH MEASUREMENT IN OSTEOARTHRITIS
    Gensburger, D.
    Roux, J.
    Arlot, M.
    Chapurlat, R.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2009, 20 : 17 - 17
  • [7] Influence of Blinding Sequence of Radiographs on the Reproducibility and Sensitivity to Change of Joint Space Width Measurement in Knee Osteoarthritis
    Gensburger, Deborah
    Roux, Jean-Paul
    Arlot, Monique
    Sornay-Rendu, Elisabeth
    Ravaud, Philippe
    Chapurlat, Roland
    [J]. ARTHRITIS CARE & RESEARCH, 2010, 62 (12) : 1699 - 1705
  • [8] Automatic quantification of osteoarthritis in hand radiographs: validation of a new method to measure joint space width
    van 't Klooster, R.
    Hendriks, E. A.
    Watt, I.
    Kloppenburg, M.
    Reiber, J. H. C.
    Stoel, B. C.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 : 572 - 572
  • [9] Automatic quantification of osteoarthritis in hand radiographs: validation of a new method to measure joint space width
    van't Klooster, R.
    Hendriks, E. A.
    Watt, I.
    Kloppenburg, M.
    Reiber, J. H. C.
    Stoel, B. C.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (01) : 18 - 25
  • [10] Detection of joint space narrowing in hand radiographs
    Moans, H. J. Bernelot
    Kauffman, J. A.
    Slump, C. H.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 : 579 - 579