Genotoxic potential of dental bulk-fill resin composites

被引:31
|
作者
Tauboeck, Tobias T. [1 ]
Marovic, Danijela [2 ]
Zeljezic, Davor [3 ]
Steingruber, Andrea D. [1 ]
Attin, Thomas [1 ]
Tarle, Zrinka [2 ]
机构
[1] Univ Zurich, Ctr Dent Med, Dept Prevent Dent Periodontol & Cariol, Plattenstr 11, CH-8032 Zurich, Switzerland
[2] Univ Zagreb, Sch Dent Med, Dept Endodont & Restorat Dent, Zagreb, Croatia
[3] Inst Med Res & Occupat Hlth, Div Mutagenesis, Zagreb, Croatia
关键词
Resin composite; Bulk-fill; Biocompatibility; Genotoxicity; Microhardness; ELECTROPHORESIS COMET ASSAY; IN-VITRO; POLYMERIZATION SHRINKAGE; MONOMER CONVERSION; DNA-DAMAGE; MECHANICAL-PROPERTIES; HUMAN-LYMPHOCYTES; FLOWABLE RESIN; CYTOME ASSAY; CURE;
D O I
10.1016/j.dental.2017.04.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective.To investigate both genotoxicity and hardening of bulk-fill composite materials applied in 4-mm layer thickness and photo-activated for different exposure times. Methods.Three flowable bulk-fill materials and one conventional flowable composite were filled in molds (height: 4 mm) and irradiated for 20 or 30 s. The top (0 mm) and bottom (4 mm) specimen surface were mechanically scraped, and eluates (0.01 g composite in 1.5 ml RPMI 1640 cell culture media) prepared for each material, surface level and irradiation time. Genotoxicity was assessed in human leukocytes using both the alkaline comet assay and cytokinesis-blocked micronucleus assay, and Knoop hardness (KHN) was measured at the top and bottom specimen surface (n = 8). Results<bold>.</bold>At both irradiation times, none of the bulk-fill composites significantly affected comet assay parameters used in primary DNA damage assessment or induced significant formation of any of the scored chromatin abnormalities (number of micronuclei, nuclear buds, nucleoplasmic bridges), whether eluates were obtained from the top or bottom surface. Furthermore, no decrease in KHN from the top to the bottom surface of the bulk-fill materials was observed. On the other hand, the conventional composite irradiated for 20 s showed at 4-mm depth a significant increase in the percentage of DNA that migrated in the tail and a significant increase in the number of nuclear buds, as well as a significant decrease in KHN relative to the top surface. Significance<bold>. </bold>Bulk-fill resin composites, in contrast to conventional composite, applied in 4-mm thickness and photo-activated for at least 20 s do not induce relevant genotoxic effects or mechanical instability. (C) 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:788 / 795
页数:8
相关论文
共 50 条
  • [1] Wear of bulk-fill resin composites
    Osiewicz, Magdalena A.
    Werner, Arie
    Roeters, Franciscus J. M.
    Kleverlaan, Cornelis J.
    [J]. DENTAL MATERIALS, 2022, 38 (03) : 549 - 553
  • [2] Polymerization efficiency of bulk-fill dental resin composites with different curing modes
    Dionysopoulos, Dimitrios
    Tolidis, Kosmas
    Gerasimou, Paris
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2016, 133 (18)
  • [3] Evaluation of Microvoid and Microleakage Potential of Bulk-Fill Resin Composites in MOD Restorations
    Canik, Goezde
    Ulusoy, Nuran
    Orhan, Kaan
    [J]. COATINGS, 2024, 14 (03)
  • [4] Surface Microhardness of Bulk-Fill Resin Composites Handled With Gloves
    Berto-Inga, Julissa
    Santander-Rengifo, Flor
    Ladera-Castaneda, Marysela
    Lopez-Gurreonero, Carlos
    Perez-Vargas, Antonieta Castro
    Cornejo-Pinto, Alberto
    Cervantes-Ganoza, Luis
    Cayo-Rojas, Cesar
    [J]. INTERNATIONAL DENTAL JOURNAL, 2023, 73 (04) : 489 - 495
  • [5] Dental Bulk-Fill Resin Composites Polymerization Efficiency: A Systematic Review and Meta-Analysis
    Ajaj, Reem A.
    Farsi, Nada J.
    Alzain, Lama
    Nuwaylati, Nour
    Ghurab, Raneem
    Nassar, Hani M.
    [J]. JOURNAL OF COMPOSITES SCIENCE, 2021, 5 (06):
  • [6] Curing profile of bulk-fill resin-based composites
    Li, Xin
    Pongprueksa, Pong
    Van Meerbeek, Bart
    De Munck, Jan
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (06) : 664 - 672
  • [7] Performance of low shrinkage Bis-EFMA based bulk-fill dental resin composites
    Ma, Xinyue
    Zhang, Xiaoqing
    Huang, Xiangya
    Liu, Fang
    He, Jingwei
    Mai, Sui
    [J]. DENTAL MATERIALS, 2024, 40 (09) : 1378 - 1389
  • [8] The effect of bleaching applications on stained bulk-fill resin composites
    Erturk-Avunduk, Ayse Tugba
    Cengiz-Yanardag, Esra
    Karakaya, Izgen
    [J]. BMC ORAL HEALTH, 2022, 22 (01)
  • [9] The effect of bleaching applications on stained bulk-fill resin composites
    Ayse Tugba Erturk-Avunduk
    Esra Cengiz-Yanardag
    Izgen Karakaya
    [J]. BMC Oral Health, 22
  • [10] Incremental and Bulk-fill Techniques With Bulk-fill Resin Composite in Different Cavity Configurations
    Han, S-H
    Park, S-H
    [J]. OPERATIVE DENTISTRY, 2018, 43 (06) : 631 - 641