An evaluation of analytic coals for assays of drugs - A College of American Pathologists Therapeutic Drug Monitoring Survey study

被引:0
|
作者
Steele, BW
Wang, E
Palomaki, GE
Klee, GG
Elin, RJ
Soldin, SJ
Witte, DL
机构
[1] Univ Miami, Sch Med, Dept Pathol, Miami, FL USA
[2] Coll Amer Pathologists, Northfield, IL USA
[3] Fdn Blood Res, Scarborough, ME 04074 USA
[4] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
[5] Univ Louisville, Dept Pathol & Lab Med, Louisville, KY 40292 USA
[6] George Washington Univ, Sch Med, Dept Pediat, Dept Lab Med,Childrens Natl Med Ctr, Washington, DC 20052 USA
[7] George Washington Univ, Sch Med, Dept Pathol, Dept Lab Med,Childrens Natl Med Ctr, Washington, DC USA
[8] Lab Control Ltd, Collaborat Lab Serv, Ottumwa, IA USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective - To determine if the levels of imprecision of the commonly used analytic methods for drug measurements are suitable for long-term therapeutic drug monitoring. Design - In 1996, 4 identical lyophilized samples (2 in the first mailing and 2 in the second mailing 4 months later) were sent to laboratories participating in a nationwide proficiency testing program. Similarly, in 1999, replicates from a liquid pool of spiked sera were mailed 3 times, 4 months apart, to participating laboratories. For each of 11 drugs regulated under the Clinical Laboratory Improvement Amendments of 1988 and 1 metabolite, the total variance for each method was partitioned into within- and between-laboratory components. The total within-laboratory and the total survey coefficients of variation (CVs) for each method were then compared with the "acceptable" precision criteria of Click, Burnett, and Fraser for each drug. Setting - The first 2 mailings of the College of American Pathologists Therapeutic Drug Monitoring surveys for 1996, sets Z and ZM, and the 3 mailings of 1999, sets ZM, Z, and Z2. Main Outcome Measures - For each drug studied, the CV of each method was compared with the various imprecision criteria, and if greater than any of the criteria, the method was then tabulated as not meeting that specific criterion. Participants - The approximately. 5000 participants of the survey. Results - The number of methods deemed as not having acceptable total long-term within-laboratory precision by the various criteria ranged from 35% to 88% in 1996 and from 22% to 77% in 1999. Conclusion - The number of failures possibly indicates that many of the reagent assays being utilized are not precise enough for long-term therapeutic drug monitoring of chronically administered drugs or that the published criteria used to evaluate the data in this study are too stringent.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 50 条
  • [1] Sources of variability - A college of American pathologists therapeutic drug monitoring survey study
    Steele, BW
    Wang, E
    Palomaki, G
    Klee, GG
    Elin, RJ
    Witte, DL
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2001, 125 (02) : 183 - 190
  • [3] Therapeutic Drug Monitoring of Second- and Third-Generation Antiepileptic Drugs Insights From a College of American Pathologists Proficiency Testing Survey
    Krasowski, Matthew D.
    Long, Thomas A.
    Snozek, Christine L. H.
    Dizon, Annabel
    Magnani, Barbarajean
    Melanson, Stacy E. F.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2021, 145 (12) : 1485 - 1491
  • [4] The updated College of American Pathologists principles of analytic validation of immunohistochemical assays: A step forward for cytopathology
    Roy-Chowdhuri, Sinchita
    CANCER CYTOPATHOLOGY, 2024, 132 (09) : 547 - 548
  • [5] A longitudinal replicate study of immunosuppressive drugs - A college of American pathologists study
    Steele, BW
    Wang, E
    Soldin, SJ
    Klee, G
    Elin, RJ
    Witte, DL
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2003, 127 (03) : 283 - 288
  • [6] College of American Pathologists Quality Cross Check -Chemistry and Therapeutic Drug Monitoring as a tool for biannual instrument correlations
    Pater, Megan S.
    Hernandez, Julia A.
    Wiencek, Joesph R.
    LABORATORY MEDICINE, 2024, 55 (04) : 460 - 463
  • [7] Evaluation of therapeutic drug monitoring of antiepileptic drugs
    Irshaid, YM
    Hamdi, AA
    Al Homrany, M
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2003, 41 (03) : 126 - 131
  • [8] Principles of Analytic Validation of Immunohistochemical Assays Guideline From the College of American Pathologists Pathology and Laboratory Quality Center
    Fitzgibbons, Patrick L.
    Bradley, Linda A.
    Fatheree, Lisa A.
    Alsabeh, Randa
    Fulton, Regan S.
    Goldsmith, Jeffrey D.
    Haas, Thomas S.
    Karabakhtsian, Rouzan G.
    Loykasek, Patti A.
    Marolt, Monna J.
    Shen, Steven S.
    Smith, Anthony T.
    Swanson, Paul E.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2014, 138 (11) : 1432 - 1443
  • [9] EVALUATION OF THE ABBOTT AXSYM FOR THERAPEUTIC DRUG-MONITORING ASSAYS
    MURTHY, JN
    COLLIERHARRIS, D
    HICKS, JM
    SOLDIN, SJ
    CLINICAL CHEMISTRY, 1995, 41 (06) : S92 - S92
  • [10] DIGOXIN THERAPEUTIC DRUG-MONITORING PRACTICES - A COLLEGE-OF-AMERICAN-PATHOLOGISTS Q-PROBES STUDY OF 666 INSTITUTIONS AND 18679 TOXIC LEVELS
    HOWANITZ, PJ
    STEINDEL, SJ
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1993, 117 (07) : 684 - 690