Constructed wetlands combined with disinfection systems for removal of urban wastewater contaminants

被引:42
|
作者
Russo, Nunziatina [1 ]
Marzo, Alessia [2 ]
Randazzo, Cinzia [1 ]
Caggia, Cinzia [1 ]
Toscano, Attilio [3 ]
Cirelli, Giuseppe Luigi [1 ]
机构
[1] Univ Catania, Dept Agr Food & Environm Di3A, Via Santa Sofia 100, I-95123 Catania, Italy
[2] Univ Catania, Ctr Conservat & Management Nat & Agroecosyst CUTG, Via Santa Sofia 98, I-95123 Catania, Italy
[3] Univ Bologna, Alma Mater Studiorum, Dept Agr & Food Sci DISTAL, Viale Giuseppe Fanin 50, I-40127 Bologna, Italy
关键词
Fecal indicators; Enterococci; Wastewater reuse lagooning UV system; HORIZONTAL SUBSURFACE-FLOW; SOURCE TRACKING MARKERS; CRYPTOSPORIDIUM-PARVUM; ESCHERICHIA-COLI; PILOT-SCALE; INDICATOR MICROORGANISMS; ANTIBIOTIC-RESISTANCE; TREATMENT PLANTS; RECLAIMED WATER; UASB REACTOR;
D O I
10.1016/j.scitotenv.2018.11.417
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal efficiency of an urban wastewater treatment plant (WWTP) to obtain an effluent suitable for agriculture reuse was evaluated in a one-year period, taking into account the Italian wastewater limits and the recent European proposal for the minimum requirements water quality for agricultural irrigation. The secondary effluent of WWTP was treated by three full-scale horizontal sub-surface flow (H-SSF) constructed wetlands (CWs), working in parallel, planted with different macrophytes species, and combined with a UV device and a lagooning system running in series. The H-SSF CW system effectively reduced physico-chemical pollutants and its efficiency was steady over the investigation period, while, Escherichia coli densities always exceed the Italian limits required for wastewater reuse in agriculture. The UV system significantly reduced the microbiological indicators, eliminating E. coli, in compliance with the Italian regulation, and somatic coliphages, although a variable efficacy against total coliforms and enterococci, especially in winter season, was achieved. Although the lagooning unit provides a high removal of the main microbial groups, it did not reduce physico-chemical parameters. Even if the overall performance target, for the whole treatment chain, met the recent log(10) reduction (>= 5.0), required by the European Commission, the persistence of enterococci, especially in winter season, poses a matter of concern for public health, for the potential risk to serve as a genetic reservoir of transferable antibiotic-resistance. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:558 / 566
页数:9
相关论文
共 50 条
  • [1] Constructed wetlands combined with UV disinfection systems for removal of enteric pathogens and wastewater contaminants
    Azaizeh, H.
    Linden, K. G.
    Barstow, C.
    Kalbouneh, S.
    Tellawi, A.
    Albalawneh, A.
    Gerchman, Y.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2013, 67 (03) : 651 - 657
  • [2] WASTEWATER DISINFECTION IN THREE HYBRID CONSTRUCTED WETLANDS
    Zurita Martinez, Florentina
    Rojas Bravo, Daniel
    Carreon-Alvarez, Alejandra
    Gutierrez-Lomeli, Melesio
    [J]. INTERCIENCIA, 2015, 40 (06) : 409 - 415
  • [3] Removal of pharmaceutical contaminants from hospital wastewater using constructed wetlands: a review
    Zeba Ali Mumtaj
    Abdul Rahman Khan
    Majed Alsubih
    Lotfi Aleya
    Roohul Abad Khan
    Saimah Khan
    [J]. Environmental Science and Pollution Research, 2024, 31 : 12856 - 12870
  • [4] Removal of pharmaceutical contaminants from hospital wastewater using constructed wetlands: a review
    Mumtaj, Zeba Ali
    Khan, Abdul Rahman
    Alsubih, Majed
    Aleya, Lotfi
    Khan, Roohul Abad
    Khan, Saimah
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (09) : 12856 - 12870
  • [5] Removal of sewage contaminants in constructed wetlands systems cultivated with Mentha aquatica
    Avelar, Fabiana Ferreira
    de Matos, Antonio Teixeira
    de Matos, Mateus Pimentel
    [J]. ENGENHARIA SANITARIA E AMBIENTAL, 2019, 24 (06) : 1259 - 1266
  • [6] Effect of Disinfection Systems on the Content of Inorganic and Organic Contaminants in Urban Wastewater
    Garcia-Delgado, C.
    Eymar, E.
    Contreras, J.
    Segura, M. L.
    Suarez-Estrella, F.
    [J]. IV INTERNATIONAL SYMPOSIUM ON ECOLOGICALLY SOUND FERTILIZATION STRATEGIES FOR FIELD VEGETABLE PRODUCTION, 2010, 852 : 269 - 274
  • [7] PERFORMANCE OF CONSTRUCTED WETLANDS SYSTEMS IN POLLUTANTS REMOVAL OF DAIRY INDUSTRY WASTEWATER
    Matos, Antonio T.
    Abrahao, Sergio S.
    Lo Monaco, Paola A. V.
    [J]. ENGENHARIA AGRICOLA, 2012, 32 (06): : 1144 - 1155
  • [8] A review on constructed wetlands for environmental and emerging contaminants removal from wastewater: traditional and recent developments
    Muduli, Monali
    Choudharya, Meena
    Ray, Sanak
    [J]. ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2023,
  • [9] Occurrence and removal of quinolone, tetracycline, and macrolide antibiotics from urban wastewater in constructed wetlands
    Dan, A.
    Zhang, Xiaomeng
    Dai, Yunv
    Chen, Chunxing
    Yang, Yang
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 252
  • [10] Comprehensive evaluation of substrate materials for contaminants removal in constructed wetlands
    Wang, Yanting
    Cai, Zhengqing
    Sheng, Sheng
    Pan, Fei
    Chen, Fenfei
    Fu, Jie
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 701