Evaluation of different liquid chromatography-electrospray mass spectrometry systems for the analysis of heterocyclic amines

被引:41
|
作者
Barceló-Barrachina, E [1 ]
Moyano, E [1 ]
Puignou, L [1 ]
Galceran, MT [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
mass spectra; liquid chromatography-mass spectrometry; amines; heterocyclic aromatic;
D O I
10.1016/j.chroma.2003.10.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three liquid chromatography-electrospray ionisation (LC-ESI) MS systems are evaluated for the analysis of heterocyclic amines (HAs). The electrospray sources and analysers (ion trap, single quadrupole and triple quadrupole) have been compared in terms of performance and quality parameters. In all cases, a C-8 reversed-phase column and (acetic acid-ammonium acetate 30 mM pH 4.5)-acetonitrile (ACN) as mobile phase were used. Ionisation source parameters, post-column addition and working conditions for each acquisition mode (full scan, product ion scan, selected ion monitoring, and multiple reaction monitoring) were optimised for each instrument. The MS-MS spectra obtained with the ion trap and the triple quadrupole systems were very similar in both fragment ions and relative abundances, except for carbolines that showed adduct formation in the ion trap. Quality parameters were established and good precision (relative standard deviations (R.S.D.) < 12%) and very low limits of detection were obtained, mainly when using the triple quadrupole (<9 pg injected). The content of HAs in a lyophilised beef extract was determined using the three instruments in order to compare their applicability for routine HAs analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 50 条
  • [1] Evaluation of reversed-phase columns for the analysis of heterocyclic aromatic amines by liquid chromatography -: electrospray mass spectrometry
    Barceló-Barrachina, E
    Moyano, E
    Puignou, L
    Galceran, MT
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (01): : 45 - 59
  • [2] Determination of heterocyclic amines by pneumatically assisted electrospray liquid chromatography mass spectrometry
    Galceran, MT
    Moyano, E
    Puignou, L
    Pais, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 730 (1-2) : 185 - 194
  • [3] Liquid chromatography-electrospray mass spectrometry and tandem mass spectrometry of ceramides
    Raith, K
    Neubert, RHH
    [J]. ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 295 - 303
  • [4] Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry
    Bévalot, F
    Gaillard, Y
    Lhermitte, MA
    Pépin, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 227 - 236
  • [5] Analysis of oak tannins by liquid chromatography-electrospray ionisation mass spectrometry
    Mämmelä, P
    Savolainen, H
    Lindroos, L
    Kangas, J
    Vartiainen, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (01) : 75 - 83
  • [6] Analysis of corticosteroids by high performance liquid chromatography-electrospray mass spectrometry
    Panusa, A
    Ottaviani, M
    Picardo, M
    Camera, E
    Gagliardi, L
    Chimenti, P
    Granese, A
    Tonelli, D
    [J]. ANALYST, 2004, 129 (08) : 719 - 723
  • [7] Quantitation of 13 heterocyclic aromatic amines in cooked beef, pork, and chicken by liquid chromatography-electrospray ionization/tandem mass spectrometry
    Ni, Weijuan
    McNaughton, Lynn
    LeMaster, David M.
    Sinha, Rashmi
    Turesky, Robert J.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (01) : 68 - 78
  • [8] Evaluation of the sensitivity of miniaturized liquid chromatography-electrospray ionization-mass spectrometry for pharmaceutical analysis
    Kranendijk, M
    Waterval, JCM
    Somsen, GW
    de Jong, GJ
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (14) : 1796 - 1802
  • [9] Evaluation of capillary liquid chromatography-electrospray ionization ion mobility spectrometry with mass spectrometry detection
    Matz, LM
    Dion, HM
    Hill, HH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 59 - 68
  • [10] Analysis of theaflavins in biological fluids using liquid chromatography-electrospray mass spectrometry
    Mulder, TPJ
    van Platerink, CJ
    Schuyl, PJW
    van Amelsvoort, JMM
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 760 (02): : 271 - 279