Effects of physics change in Monte Carlo code on electron pencil beam dose distributions

被引:1
|
作者
Toutaoui, Abdelkader [1 ]
Khelassi-Toutaoui, Nadia [1 ]
Brahimi, Zakia [1 ]
Chami, Ahmed Chafik [2 ]
机构
[1] Ctr Rech Nucl Alger, Dept Phys Med, Algiers, Algeria
[2] Univ Sci & Technol Houari Boumedienne, Fac Phys, Nucl Sci Lab, Algiers, Algeria
关键词
Pencil beam kernels; Monte Carlo; Electron beams; MULTIPLE-SCATTERING; NUMERICAL-METHOD; PHOTON BEAMS; TRANSPORT; ALGORITHM; HISTORY; MODEL; EGS4;
D O I
10.1016/j.radphyschem.2011.08.009
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Pencil beam algorithms used in computerized electron beam dose planning are usually described using the small angle multiple scattering theory. Alternatively, the pencil beams can be generated by Monte Carlo simulation of electron transport. In a previous work, the 4th version of the Electron Gamma Shower (EGS) Monte Carlo code was used to obtain dose distributions from monoenergetic electron pencil beam, with incident energy between 1 MeV and 50 MeV, interacting at the surface of a large cylindrical homogeneous water phantom. In 2000, a new version of this Monte Carlo code has been made available by the National Research Council of Canada (NRC), which includes various improvements in its electron transport algorithms. In the present work, we were interested to see if the new physics in this version produces pencil beam dose distributions very different from those calculated with oldest one. The purpose of this study is to quantify as well as to understand these differences. We have compared a series of pencil beam dose distributions scored in cylindrical geometry, for electron energies between 1 MeV and 50 MeV calculated with two versions of the Electron Gamma Shower Monte Carlo Code. Data calculated and compared include isodose distributions, radial dose distributions and fractions of energy deposition. Our results for radial dose distributions show agreement within 10% between doses calculated by the two codes for voxels closer to the pencil beam central axis, while the differences are up to 30% for longer distances. For fractions of energy deposition, the results of the EGS4 are in good agreement (within 2%) with those calculated by EGSnrc at shallow depths for all energies, whereas a slightly worse agreement (15%) is observed at deeper distances. These differences may be mainly attributed to the different multiple scattering for electron transport adopted in these two codes and the inclusion of spin effect, which produces an increase of the effective range of electrons. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Electron fields in clinical use - a comparison of the pencil beam method and Monte Carlo code
    Treutwein, M.
    Bogner, L.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 100 - 100
  • [2] Dose to Proximal Bronchial Tree in Lung SBRT Treatments: Comparison of Pencil Beam and Monte Carlo Dose Distributions
    Altunbas, C.
    Miften, M.
    Stuhr, K.
    Gaspar, L.
    Kavanagh, B.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3276 - +
  • [3] Evaluating Pencil Beam Dose Algorithm in Lung with Monte Carlo
    Depauw, N.
    Seco, J.
    Adams, J.
    Panahandeh, H.
    Paganetti, H.
    Kooy, H.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [5] Comparison of Monte Carlo and pencil beam electron planning algorithms
    Perrett, T
    Gray, K
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S92 - S92
  • [6] A PENCIL BEAM REDEFINITION ALGORITHM FOR ELECTRON DOSE DISTRIBUTIONS
    SHIU, AS
    HOGSTROM, KR
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 473 - 474
  • [7] Characterising an electron pencil beam: Monte Carlo vs measurement
    Ebert, M
    Barnes, M
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2015 - 2016
  • [8] Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms
    Kang, Sei-Kwon
    Yoon, Jai-Woong
    Hwang, Taejin
    Park, Soah
    Cheong, Kwang-Ho
    Han, Tae Jin
    Kim, Haeyoung
    Lee, Me-Yeon
    Kim, Kyoung Ju
    Bae, Hoonsik
    [J]. MEDICAL DOSIMETRY, 2015, 40 (03) : 240 - 243
  • [9] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Schwarz, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8601 - 8619