A robust contour preserving image reconstruction algorithm for a new quantum X-ray radiology system

被引:0
|
作者
Kam, L [1 ]
Cudel, C [1 ]
Fessler, P [1 ]
Hilt, B [1 ]
Vapillon, A [1 ]
机构
[1] GIP, CTA, DCE, DGA, Arcueil, France
来源
PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND | 1998年 / 20卷
关键词
quantum X-ray radiology; ultra low dose; image reconstruction; interpolation; contour preserving;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We propose a robust algorithm for the reconstruction of blind strips happening in images generated by a revolutionary new quantum X-ray radiology system. These strips are due to the gaps between the detectors. Each blind strip is three defective columns wide. It may be wider because it happens that the neighbour channels were defective. A brief review of the literature shows that classical interpolation methods are not accurate enough for contour reconstruction. We developed a robust image reconstruction method which is contour preserving. Prior to the reconstruction, we must proceed to data preprocessing,since quantum detectors related to the channels do not hale the same response. Experimental results are presented and compared to polynomial fitting.
引用
收藏
页码:707 / 710
页数:4
相关论文
共 50 条
  • [1] A NEW STATISTICAL IMAGE RECONSTRUCTION ALGORITHM FOR POLYENERGETIC X-RAY CT
    Abella, Monica
    Fessler, Jeffrey A.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 165 - 168
  • [2] New quantum detection system for very low dose X-ray radiology
    Hilt, B
    Fessler, P
    Prevot, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 38 - 44
  • [3] Image reconstruction algorithm to X-ray diffraction tomography
    Barroso, RC
    Lopes, RT
    Gonçalves, OD
    de Assis, JT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 718 - 723
  • [4] The quantum X-ray radiology apparatus
    Hilt, B
    Fessler, P
    Prévot, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 355 - 359
  • [5] ALGORITHMS FOR SPARSE X-RAY CT IMAGE RECONSTRUCTION OF OBJECTS WITH KNOWN CONTOUR
    Dogandzic, Aleksandar
    Gu, Renliang
    Qiu, Kun
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 31A AND 31B, 2012, 1430 : 597 - 604
  • [6] Localizing contour points for indexing an x-ray image retrieval system
    Xu, XQ
    Lee, DJ
    Antani, S
    Long, LR
    CBMS 2003: 16TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2003, : 169 - 174
  • [7] An active contour algorithm for detecting the circular features in a PCB x-ray image
    Chen, YS
    Wu, CH
    Hu, WF
    MACHINE VISION APPLICATIONS IN INDUSTRIAL INSPECTION XIV, 2006, 6070
  • [8] X-ray fluorescence tomographic system design and image reconstruction
    Cong, Wenxiang
    Shen, Haiou
    Cao, Guohua
    Liu, Hong
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (01) : 1 - 8
  • [9] 3-DIMENSIONAL X-RAY IMAGE-RECONSTRUCTION ALGORITHM
    JHUNG, KS
    CHAY, TR
    MATHEMATICAL BIOSCIENCES, 1977, 35 (3-4) : 175 - 185
  • [10] COMPUTER ALGORITHM FOR TOMOGRAPHIC IMAGE RECONSTRUCTION WITH X-RAY TRANSMISSION SCANS
    CHO, ZH
    AHN, IS
    COMPUTERS AND BIOMEDICAL RESEARCH, 1975, 8 (01): : 8 - 25