A MINIATURE SURFACE PLASMON RESONANCE BIOANALYTICAL SYSTEM FOR FIELD DETECTION OF MICROCYSTIN-LR IN SURFACE WATER

被引:6
|
作者
Chen, Huibin [1 ,2 ]
Wang, Xiaoping [1 ]
Zhan, Shuyue [1 ]
Luo, Zhaofeng [3 ,4 ]
Zhou, Hongmin [3 ,4 ]
机构
[1] Zhejiang Univ, State Key Lab Modern Opt Instrumentat, Dept Opt Engn & Informat Sci, Hangzhou 310003, Zhejiang, Peoples R China
[2] Jimei Univ, Informat Sci & Engn Coll, Xiamen, Fujian, Peoples R China
[3] Univ Sci & Technol China, Hefei Natl Lab Phys Sci Microscale, Hefei 230026, Anhui, Peoples R China
[4] Univ Sci & Technol China, Sch Life Sci, Hefei 230026, Anhui, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
free-labeling; microcystin-LR; rapid detection; reusable biosensor; surface plasmon resonance; LIQUID-CHROMATOGRAPHY; PROTEIN PHOSPHATASE; IMMUNOASSAY; BIOSENSOR; ASSAY; ANTIBODY;
D O I
10.1080/10739149.2011.601387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniature surface plasmon resonance (SPR)-based immunoassay system for analyzing microcystin-LR (MC-LR) in surface water has been developed. A Spreeta biosensor was adopted in the SPR flow injection analysis (FIA) system. An optional biofilm immobilization method was exploited using covalent-coupling between a bioconjugate of microcystin-LR and bovine serum albumin [(MC-LR)-BSA] and the golden surface. An acceptable relative standard deviation of repeatability, 1.29% (n = 20), was achieved. An analysis of the calibration curve showed that this method has a detection limit of 0.55 ng/mL, a half-maximal inhibitory concentration (IC50) of 5.6 ng/mL, and a quantitative range of 1.56-25.00 ng/mL. The recovery from water samples containing varying concentrations of MC-LR ranged from 90% to 112%. After samples of tap water and pool water were assayed, it was concluded that tap water did not contain a measurable amount of the analyte, whereas pool water contained 2.39 ng/mL. Compared to other methods of analysis, SPR immunoassay has the advantage of being label-free, rapid, and cost-effective and can easily detect levels of MC-LR within the World Health Organization (WHO) drinking water guidelines. The SPR FIA system with reusable biosensor is compact and convenient for instant in situ determination of MC-LR levels in environmental water.
引用
收藏
页码:462 / 474
页数:13
相关论文
共 50 条
  • [1] Surface plasmon resonance sensor coated with poriferous MIPs for microcystin-LR detection
    He, Hao
    Zhang, Tao
    Yao, Jia
    Li, Chuan-Yu
    Zhou, Lian-Qun
    Wang, Yi
    Li, Ming-Yu
    Li, Hai-Wen
    Dong, Wen-Fei
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (03): : 723 - 728
  • [2] Surface plasmon resonance coupled with molecularly imprinted polymers for detecting microcystin-LR
    Osten, Donald E.
    Jang, Min
    Park, Jae K.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1597 - U1597
  • [3] Longitudinal surface plasmon resonance assay enhanced by magnetosomes for simultaneous detection of Pefloxacin and Microcystin-LR in seafoods
    Sun, Xiulan
    Wu, Longyun
    Ji, Jian
    Jiang, Donglei
    Zhang, Yinzhi
    Li, Zaijun
    Zhang, Genyi
    Zhang, Hongxia
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 47 : 318 - 323
  • [4] Microcystin-LR in surface water of Ponjavica River
    Natic, Dejan
    Jovanovic, Dragana
    Knezevic, Tanja
    Karadzic, Vesna
    Bulat, Zorica
    Matovic, Vesna
    [J]. VOJNOSANITETSKI PREGLED, 2012, 69 (09) : 753 - 758
  • [5] Enhanced cathodic electrochemiluminescent microcystin-LR aptasensor based on surface plasmon resonance of Bi nanoparticles
    Yuan, Ruishuang
    Liu, Qian
    Hong, Honghong
    Ma, Hanyu
    Xiao, Liting
    Li, Yaqi
    Jiang, Ding
    Hao, Nan
    Wang, Kun
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2022, 434
  • [6] An automatic miniature surface plasmon resonance system for cortisol detection
    Zhang, Lulu
    Chen, Xing
    Wei, Wei
    Deng, Shaoli
    Xu, Chunfang
    Cui, Dafu
    [J]. BIOSENSORS 2016, 2017, 27 : 89 - 90
  • [7] Highly sensitive detection of the hepatotoxin microcystin-LR by surface modification and bio-nanotechnology
    Han, Jianhua
    Zhang, Jianping
    Xia, Yuetong
    Jiang, Long
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2011, 391 (1-3) : 184 - 189
  • [8] Phosphorescent immunosensor for simple and sensitive detection of microcystin-LR in water
    Qin, Jin
    Sun, Xiaojie
    Li, Dongxia
    Yan, Guiqin
    [J]. RSC ADVANCES, 2019, 9 (22): : 12747 - 12754
  • [9] Optical Cavity Fibre Sensor for Detection of Microcystin-LR in Water
    Queiros, Raquel B.
    Silva, S. O.
    Sales, M. G. F.
    Noronha, J. P.
    Frazao, O.
    Jorge, P. A. S.
    Aguilar, G. G.
    [J]. FOURTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2010, 7653
  • [10] SURFACE-PLASMON RESONANCE AS A BIOANALYTICAL TOOL
    KOOYMAN, RPH
    DEBRUIJN, HE
    EENINK, RG
    GREVE, J
    [J]. JOURNAL OF MOLECULAR STRUCTURE, 1990, 218 : 345 - 350