Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy

被引:30
|
作者
Tedgren, Asa Carlsson [1 ]
Ahnesjoe, Anders [2 ]
机构
[1] Linkoping Univ, Fac Hlth Sci, Dept Med & Hlth Sci, Linkoping, Sweden
[2] Uppsala Univ, Dept Oncol Radiol & Clin Immunol, Sect Oncol, Uppsala, Sweden
关键词
brachytherapy; dose calculation; heterogeneities; collapsed cone; Monte Carlo;
D O I
10.1118/1.2889777
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brachytherapy dose calculations based on point kernel superposition using the collapsed cone method have been shown to accurately model the influence from finite dimensions of the patient and effects from heterogeneities including those of high atomic numbers. The collapsed cone method is for brachytherapy applications most effectively implemented through a successive-scattering approach, in which the dose from once and higher order of scattered photons is calculated separately and in successive scatter order. The calculation speed achievable is directly proportional to the number of directions used for point kernel discretization and to the number of voxels in the volume. In this work we investigate how to best divide the total number of directions between the two steps of successive-scattering dose calculations. Results show that the largest fraction of the total number of directions should be utilized in calculating the first-scatter dose. Also shown is how the number of directions required for keeping discretization artifacts at acceptably low levels decreases significantly in multiple-source configurations, as a result of the dose gradients being less steep than those around single sources. Investigating the number of kernel directions required to keep artifacts low enough within the high dose region of an implant (i.e., for dose levels above approximately 5%-10% of the mean central target dose) reveals similar figures for brachytherapy as for external beam applications, where collapsed cone superposition is clinically used. Also shown is that approximating point kernels with their isotropic average leads to small dose differences at low and intermediate energies, implying that the collapsed cone calculations can be done in a single operation common to all sources of the implant at these energies. The current findings show that collapsed cone calculations can be achieved for brachytherapy with the same efficiency as for external beams. This, combined with recent results on gains in efficiency through implementing the algorithm on graphical card parallel hardware indicates that dose can be calculated with account for heterogeneities and finite dimensions within a few seconds for large voxel arrays and is therefore of interest for practical application to treatment planning. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1611 / 1618
页数:8
相关论文
共 50 条
  • [1] Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy
    Tedgren, A. Carlsson
    Ahnesjo, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S197 - S197
  • [2] Evaluation of Collapsed Cone Dose Calculation Algorithm for HDR Brachytherapy Using Monte Carlo
    Volken, W.
    Terribilini, D.
    Fix, M. K.
    Loessl, K.
    van Veelen, B.
    Manser, P.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [3] The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    Carlsson, ÅK
    Ahnesjö, A
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2320 - 2332
  • [4] A Study of Dose Calculation Based on Collapsed Cone Convolution Algorithm
    Zhou, Zhengdong
    Song, Wei
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1331 - 1335
  • [5] Accounting for heterogeneities and shields in brachytherapy dose calculation bg use of collapsed cone superposition
    Carlsson, ÅK
    Ahnesjö, A
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 474 - 476
  • [6] Commissioning of Advanced Collapsed Cone Engine Algorithm for Brachytherapy
    Swamidas, J.
    Parida, S.
    Joshi, K.
    Phurailatpam, R.
    Panda, S.
    Pradhan, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E447 - E447
  • [7] Evaluation of the RadCalc collapsed cone dose calculation algorithm against measured data
    Richmond, Neil
    Chester, Katherine
    Manley, Steven
    [J]. MEDICAL DOSIMETRY, 2023, 48 (04) : 216 - 224
  • [8] Accounting for high Z shields in brachytherapy using collapsed cone superposition for scatter dose calculation
    Tedgren, ÅKC
    Ahnesjö, A
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2206 - 2217
  • [9] Collapsed cone algorithm and its impact on dose distributions in HDR brachytherapy for partial breast irradiations
    Terribilini, D.
    Volken, W.
    Fix, M. K.
    Loessl, K.
    van Veelen, B.
    Manser, P.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1077 - 1077
  • [10] PENCIL BEAM VS COLLAPSED CONE TREATMENT PLANNING SYSTEM CALCULATION ALGORITHM IN 3D PLANNING OF LUNG CANCER.
    Paschalis, T.