Detection of legionellae in hospital water samples by quantitative real-time LightCycler PCR

被引:175
|
作者
Wellinghausen, N [1 ]
Frost, C [1 ]
Marre, R [1 ]
机构
[1] Univ Ulm, Dept Med Microbiol & Hyg, D-89081 Ulm, Germany
关键词
D O I
10.1128/AEM.67.9.3985-3993.2001
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.
引用
收藏
页码:3985 / 3993
页数:9
相关论文
共 50 条
  • [1] Detection of nontuberculous mycobacteria in hospital water samples by quantitative real-time PCR and culture
    Hussein, Z.
    Wirths, B.
    Wellinghausen, N.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2006, 296 : 54 - 54
  • [2] First LightCycler real-time PCR assay for the quantitative detection of Mycoplasma suis in clinical samples
    Hoelzle, Ludwig E.
    Helbling, Marianne
    Hoelzle, Katharina
    Ritzmann, Mathias
    Heinritzi, Karl
    Wittenbrink, Max M.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 70 (02) : 346 - 354
  • [3] Specific and quantitative detection of human polyomaviruses BKV and JCV by LightCycler® real-time PCR
    Sehbani, Laïla
    Kabamba-Mukadi, Benoît
    Vandenbroucke, Anne-Thérèse
    Bodéus, Monique
    Goubau, Patrick
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2006, 36 (02) : 159 - 162
  • [4] A duplex real-time PCR assay for the quantitative detection of Naegleria fowleri in water samples
    Behets, Jonas
    Declerck, Priscilla
    Delaedt, Yasmine
    Verelst, Lieve
    Ollevier, Frans
    [J]. WATER RESEARCH, 2007, 41 (01) : 118 - 126
  • [5] Detection of bacterial strains by real-time PCR using the LightCycler™.
    Basalyga, F
    Davis, A
    Thompson, BH
    Simpson, JT
    [J]. AMERICAN JOURNAL OF HUMAN GENETICS, 2000, 67 (04) : 253 - 253
  • [6] Detection of porcine teschoviruses and enteroviruses by LightCycler real-time PCR
    Krumbholz, A
    Wurm, R
    Scheck, O
    Birch-Hirschfeld, E
    Egerer, R
    Henke, A
    Wutzler, P
    Zell, R
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2003, 113 (01) : 51 - 63
  • [7] A real-time PCR assay for the detection of Neisseria gonorrhoeae by LightCycler
    Whiley, DM
    LeCornec, GM
    Mackay, IM
    Siebert, DJ
    Sloots, TP
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2002, 42 (02) : 85 - 89
  • [8] Quantitative real-time LightCycler PCR for investigation of Legionella in 81 industrial cooling water systems
    Bernier, M
    Baillet, B
    Dupuy, S
    Fabre, R
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2004, 24 : S190 - S190
  • [9] Legionella detection from water samples by real-time PCR
    Franzin, Laura
    Cabodi, Daniela
    Bonfrate, Nicoletta
    [J]. LEGIONELLA: STATE OF THE ART 30 YEARS AFTER ITS RECOGNITION, 2006, : 446 - +
  • [10] Specific detection of Candida albicans using real-time PCR on the LightCycler™
    O'Connor, L.
    Ruttledge, M.
    Maher, M.
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : 533 - 533