The effect of endograft device on patient outcomes in endovascular repair of ruptured abdominal aortic aneurysms

被引:8
|
作者
Kansal, Vinay [1 ]
Nagpal, Sudhir [2 ,3 ]
Jetty, Prasad [2 ,3 ]
机构
[1] Univ Ottawa, Fac Med, Ottawa, ON, Canada
[2] Univ Ottawa, Div Vasc Surg, Ottawa, ON, Canada
[3] Ottawa Hosp, Res Inst, Ottawa, ON, Canada
关键词
Endovascular aneurysm repair; EVAR; rupture; abdominal aortic aneurysm; device; instructions for use; ENDURANT STENT GRAFT; OPEN SURGERY; MORTALITY; METAANALYSIS; TRIAL; EVAR;
D O I
10.1177/1708538117711348
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Endovascular aneurysm repair for ruptured abdominal aortic aneurysm is being increasingly applied as the intervention of choice. The purpose of this study was to determine whether survival and reintervention rates after ruptured abdominal aortic aneurysm vary between endograft devices. Methods: This cohort study identified all ruptured abdominal aortic aneurysms performed at The Ottawa Hospital from January 1999 to May 2015. Data collected included patient demographics, stability index at presentation, adherence to device instructions for use, endoleaks, reinterventions, and mortality. Kruskal-Wallis test was used to compare outcomes between groups. Mortality outcomes were assessed using Kaplan-Meier survival analysis, and multivariate Cox regression modeling. Results: One thousand sixty endovascular aneurysm repairs were performed using nine unique devices. Ninety-six ruptured abdominal aortic aneurysms were performed using three devices: Cook Zenith (n=46), Medtronic Endurant (n=33), and Medtronic Talent (n=17). The percent of patients presented in unstable or extremis condition was 30.2, which did not differ between devices. Overall 30-day mortality was 18.8%, and was not statistically different between devices (p=0.16), although Medtronic Talent had markedly higher mortality (35.3%) than Cook Zenith (15.2%) and Medtronic Endurant (15.2%). AUI configuration was associated with increased 30-day mortality (33.3% vs. 12.1%, p=0.02). Long-term mortality and graft-related reintervention rates at 30 days and 5 years were similar between devices. Instructions for use adherence was similar across devices, but differed between the ruptured abdominal aortic aneurysm and elective endovascular aneurysm repair cohorts (47.7% vs. 79.0%, p<0.01). Notably, two patients who received Medtronic Talent grafts underwent open conversion >30 days post-endovascular aneurysm repair (p=0.01). Type 1 endoleak rates differed significantly across devices (Cook Zenith 0.0%, Medtronic Endurant 18.2%, Medtronic Talent 17.6%, p=0.01). Conclusion: Although we identified device-related differences in endoleak rates, there were no significant differences in reintervention rates or mortality outcomes. Favorable outcomes of Cook Zenith and Medtronic Endurant over Medtronic Talent reflect advances in endograft technology and improvements in operator experience over time. Results support selection of endograft by operator preference for ruptured abdominal aortic aneurysm.
引用
收藏
页码:657 / 665
页数:9
相关论文
共 50 条
  • [1] Endovascular Repair of Ruptured Abdominal Aortic Aneurysms: Are Outcomes Device Dependent?
    Kansal, Vinay
    Nagpal, Sudhir
    Jetty, Prasad
    [J]. JOURNAL OF VASCULAR SURGERY, 2016, 64 (05) : 1540 - 1541
  • [2] Endovascular Repair of Ruptured Abdominal Aortic Aneurysms Using the Endurant™ Endograft
    Nana, Petroula
    Volakakis, George
    Spanos, Konstantinos
    Kouvelos, George
    Bareka, Metaxia
    Arnaoutoglou, Eleni
    Giannoukas, Athanasios
    Matsagkas, Miltiadis
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [3] Endovascular repair of ruptured abdominal aortic aneurysms
    De Rango, P.
    Estrera, A. L.
    Safi, H. J.
    Azizzadeh, A.
    [J]. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 16 (03): : 151 - 161
  • [4] Impact of endovascular repair on early outcomes of ruptured abdominal aortic aneurysms
    Lee, WA
    Hirneise, CM
    Tayyarah, M
    Huber, TS
    Seeger, JM
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 40 (02) : 211 - 215
  • [5] Regarding "Endovascular repair of ruptured abdominal aortic aneurysms"
    Takagi, Hisato
    Kawai, Norikazu
    Umemoto, Takuya
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (01) : 253 - 254
  • [6] Endovascular or open repair of ruptured abdominal aortic aneurysms
    Reinecke, Holger
    Donas, Konstantinos P.
    [J]. VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2016, 45 (04) : 342 - 342
  • [7] Endovascular Repair First for Ruptured Abdominal Aortic Aneurysms
    Galovich, Justin
    Donayre, Carlos
    Lin, John
    Walot, Irwin
    White, Rodney A.
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2013, 40 (05) : 553 - 555
  • [8] Anaesthesia for endovascular repair of ruptured abdominal aortic aneurysms
    Mouton, R.
    Rogers, C. A.
    Harris, R. A.
    [J]. BJA EDUCATION, 2022, 22 (06) : 208 - 215
  • [9] Revisiting Endovascular Repair for Ruptured Abdominal Aortic Aneurysms
    Das, Chandan
    Nazzal, Munier
    Adair, Marcus J.
    Markowiak, Stephen F.
    Wisniewski, Alexander
    [J]. JOURNAL OF VASCULAR SURGERY, 2018, 67 (06) : E185 - E186
  • [10] Is endovascular repair of ruptured abdominal aortic aneurysms feasible?
    Albertini, JN
    Macierewicz, J
    Yusuf, SW
    Wenham, PW
    Hopkinson, BR
    [J]. JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (01): : 77 - 77