Seismic and vibration tests for assessing the effectiveness of GFRP for retrofitting masonry structures

被引:4
|
作者
Michelis, Paul [2 ]
Papadimitriou, Costas [1 ]
Karaiskos, Grigoris K. [1 ]
Papadioti, Dimitra-Christina [1 ]
Fuggini, Clemente [3 ]
机构
[1] Univ Thessaly, Dept Mech Engn, Volos 38334, Greece
[2] Inst Mech Mat & Geostruct SA, Penteli 15236, Greece
[3] DAppolonia SpA, Ind Innovat Div, I-20097 San Donato Milanese, MI, Italy
关键词
masonry structures; glass fiber reinforced polymers; shake table tests; structural identification; health monitoring; damage assessment; WALLS; MODEL; PERFORMANCE; BEHAVIOR;
D O I
10.12989/sss.2012.9.3.207
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Full-scale shake table seismic experiments and low-amplitude vibration tests on a masonry building are carried out to assess its seismic performance as well as study the effectiveness of a new multifunctional textile material for retrofitting masonry structures against earthquakes. The un-reinforced and the retrofitted with glass fiber reinforced polymer (GFRP) strips masonry building was subjected to a series of earthquake excitations of increasing magnitude in order to progressively induce various small, moderate and severe levels of damage to the masonry walls. The performance of the original and retrofitted building states is evaluated. Changes in the dynamic characteristics (lowest four modal frequencies and damping ratios) of the building are used to assess and quantify the damage states of the masonry walls. For this, the dynamic modal characteristics of the structure states after each earthquake event were estimated by performing low-amplitude impulse hammer and sine-sweep forced vibration tests. Comparisons between the modal results calculated using traditional accelerometers and those using Fiber Bragg Grating (FBG) sensors embedded in the reinforcing textile were carried on to investigate the reliability and accuracy of FBG sensors in tracking the dynamic behaviour of the building. The retrofitting actions restored the stiffness characteristics of the reinforced masonry structure to the levels of the original undamaged un-reinforced structure. The results show that despite a similar dynamic behavior identified, corresponding to reduction of the modal frequencies, the un-reinforced masonry building was severely damaged, while the reinforced masonry building was able to withstand, without visual damage, the induced strong seismic excitations. The applied GFRP reinforcement architecture for one storey buildings was experimentally proven reliable for the most severe earthquake accelerations. It was easily placed in a short time and it is a cost effective solution (covering only 20% of the external wall surfaces) when compared to the cost for full wall coverage by GFRPs.
引用
收藏
页码:207 / 230
页数:24
相关论文
共 50 条
  • [1] Study on the application of ambient vibration tests to evaluate the effectiveness of seismic retrofitting
    Li Liang
    Takaaki, Ohkubo
    Li Guang-hui
    [J]. 3RD INTERNATIONAL CONFERENCE ON ENERGY EQUIPMENT SCIENCE AND ENGINEERING (ICEESE 2017), 2018, 128
  • [2] In-plane retrofitting of masonry structures by using GFRP strips in the bedjoints
    Elshan Ahani
    Fathollah Osmanzadeh
    Mir Naghi Mousavi
    Behzad Rafezy
    [J]. Bulletin of Earthquake Engineering, 2022, 20 : 4259 - 4288
  • [3] In-plane retrofitting of masonry structures by using GFRP strips in the bedjoints
    Ahani, Elshan
    Osmanzadeh, Fathollah
    Mousavi, Mir Naghi
    Rafezy, Behzad
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (08) : 4259 - 4288
  • [4] SEISMIC TESTS OF STRUCTURES WITH MASONRY VENEER
    Mclean, D. I.
    Klingner, R. E.
    Shing, P. B.
    Mcginley, W. M.
    Okail, H.
    Jo, S.
    [J]. PROCEEDINGS OF THE 9TH AUSTRALASIAN MASONRY CONFERENCE, 2011, : 237 - 246
  • [5] Seismic retrofitting of the historical masonry structures using numerical approach
    Akcay, Cemil
    Bozkurt, Tank Serhat
    Sayin, Baris
    Yildizlar, Baris
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 113 : 752 - 763
  • [6] Seismic evaluation and retrofitting of the structures of the Sadaghiani masonry historical complex
    Kheirollahi, Mohammad
    Mirzaei, Moein
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [7] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Rawa Asaad
    Ammar Kaadan
    [J]. Arabian Journal for Science and Engineering, 2024, 49 : 5243 - 5254
  • [8] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Asaad, Rawa
    Kaadan, Ammar
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (04) : 5243 - 5254
  • [9] Technologies for Seismic Retrofitting and Strengthening of Earthen and Masonry Structures: Assessment and Application
    Lourenco, Paulo B.
    [J]. RECENT ADVANCES IN EARTHQUAKE ENGINEERING IN EUROPE, 2018, 46 : 501 - 518
  • [10] Effectiveness of seismic retrofit for stone masonry structures
    Kilar, V.
    Marusic, D.