Electrochemical immunosensor for the detection of colistin in chicken liver

被引:4
|
作者
Kumar, Harsh [1 ]
Valko, Marian [2 ,3 ]
Alomar, Suliman Y. [3 ]
Alwasel, Saleh H. [3 ]
Cruz-Martins, Natalia [4 ,5 ,6 ]
Kuca, Kamil [7 ,8 ]
Kumar, Dinesh [1 ]
机构
[1] Shoolini Univ Biotechnol & Management Sci, Sch Bioengn & Food Technol, Solan 173229, India
[2] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Phys Chem & Chem Phys, Bratislava 81237, Slovakia
[3] King Saud Univ, Coll Sci, Zool Dept, Riyadh 11451, Saudi Arabia
[4] Univ Porto, Fac Med, Dept Biomed, P-4200319 Porto, Portugal
[5] Univ Porto, Inst Res & Innovat Hlth I3S, P-4200135 Porto, Portugal
[6] Inst Res & Adv Training Hlth Sci & Technol CESPU, Rua Cent Gandra 1317, P-4585116 Gandra, Prd, Portugal
[7] Univ Hradec Kralove, Fac Sci, Dept Chem, Hradec Kralove 50003, Czech Republic
[8] Univ Granada, Andalusian Res Inst Data Sci & Computat Intellige, Granada 18071, Spain
关键词
Chicken liver; Colistin antibiotic; Immunosensor; Specificity; Toxicity; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANTIOXIDANT CAPACITY; RESIDUAL BACITRACIN; ANIMAL-TISSUES; PRODUCTS; PLASMA; SENSOR; MILK;
D O I
10.1007/s13205-022-03252-w
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An innovative amperometric immunosensor has been developed to detect antibiotic colistin from the chicken liver. Colistin is a antibacterial peptide that has been barred for human consumption, but it is being commonly used as a veterinary drug, and as a feed additive for livestock. In the present work, an immunosensor was developed by immobilizing an anti-colistin Ab onto the CNF/AuNPs surface of the screen-printed electrode. The sensor records electrochemical response in the chicken liver spiked with colistin with CV. Additionally, the characterization of electrode surface was done with FE-SEM, FTIR, and EIS at each step of fabrication. The lower LOD was 0.89 mu gKg(-1), with a R-2 of 0.901 using CV. Further validation of the immunosensor was conducted using commercial chicken liver samples, by comparing the results to those obtained using traditional methods. The fabricated immunosensor showed high specificity towards colistin, which remained stable for 6 months but with a 13% loss in the initial CV current.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Electrochemical immunosensor for the detection of colistin in chicken liver
    Harsh Kumar
    Marian Valko
    Suliman Y. Alomar
    Saleh H. Alwasel
    Natália Cruz-Martins
    Kamil Kuča
    Dinesh Kumar
    3 Biotech, 2022, 12
  • [2] Paper-based electrochemical immunosensor for highly sensitive detection of chicken anemia virus
    Peala, Wisuttiya
    Kitchanakan, Phatpimol
    Khongchareonporn, Nanthika
    Angsujinda, Kitipong
    Sittidech, Akekarach
    Wanganurakkul, Saruda
    Chintapitaksakul, Lerdchai
    Suea-Ngam, Akkapol
    Wang, Sheng-Fan
    Kunpatee, Kanjana
    Chaiyo, Sudkate
    Assavalapsakul, Wanchai
    TALANTA, 2024, 272
  • [3] Paper-based electrochemical immunosensor for highly sensitive detection of chicken anemia virus
    Peala, Wisuttiya
    Kitchanakan, Phatpimol
    Khongchareonporn, Nanthika
    Angsujinda, Kitipong
    Sittidech, Akekarach
    Wanganurakkul, Saruda
    Chintapitaksakul, Lerdchai
    Suea-Ngam, Akkapol
    Wang, Sheng-Fan
    Kunpatee, Kanjana
    Chaiyo, Sudkate
    Assavalapsakul, Wanchai
    Talanta, 2024, 272
  • [4] Electrochemical Immunosensor for the Detection of Cortisol
    Kaushik, A. K.
    Sagar, V
    Jayant, R. D.
    Nair, M.
    JOURNAL OF NEUROIMMUNE PHARMACOLOGY, 2014, 9 (01) : 27 - 28
  • [5] Electrochemical immunosensor for the detection of atrazine
    López, MA
    Ortega, F
    Domínguez, E
    Katakis, I
    JOURNAL OF MOLECULAR RECOGNITION, 1998, 11 (1-6) : 178 - 181
  • [6] Chicken IgY based electrochemical immunosensor for the detection of bacterial pathogen E. coli in water
    Ganesan, Harshithaa
    Suresh, Indhu
    Indhuprakash, Srichandrasekar Thuthikkadu
    Diraviyam, Thirumalai
    Rayappan, John Bosco Balaguru
    MICROCHEMICAL JOURNAL, 2024, 204
  • [7] Electrochemical impedance immunosensor for ferritin detection
    Mengulluogh, U.
    Dinckaya, E.
    NEW BIOTECHNOLOGY, 2018, 44 : S146 - S146
  • [8] Electrochemical immunosensor for detection of Francisella tularensis
    Skladal, P
    Symerska, Y
    Pohanka, M
    Safar, B
    Macela, A
    Defense Against Bioterror: Detection Technologies, Implementation Strategies and Commercial Opportunities, 2005, 1 : 221 - 232
  • [9] Development of an electrode immunosensor using carbon nanofibres-gold nanoparticles-mercaptopropionic acid-polyethylenimine for chicken liver containing colistin
    Kumar, Harsh
    Kumar, Dinesh
    Valko, Marian
    Manickam, Sivakumar
    Alomar, Suliman Y.
    Cruz-Martins, Natalia
    Kuca, Kamil
    JOURNAL OF AGRICULTURE AND FOOD RESEARCH, 2024, 15
  • [10] Detection of Salmonella typhimurium using an electrochemical immunosensor
    Salam, Faridah
    Tothill, Ibtisam E.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2630 - 2636