Multivariate optimization of a microextraction by packed sorbent-programmed temperature vaporization-gas chromatography-tandem mass spectrometry method for organophosphate flame retardant analysis in environmental aqueous matrices

被引:14
|
作者
Naccarato, Attilio [1 ]
Elliani, Rosangela [2 ]
Sindona, Giovanni [2 ]
Tagarelli, Antonio [2 ]
机构
[1] UNICAL Polifunz, Div Rende, Inst Atmospher Pollut Res, CNR, I-87036 Arcavacata Di Rende, Italy
[2] Univ Calabria, Dipartimento Chim & Tecnol Chimiche, Via P Bucci Cubo 12-C, I-87030 Arcavacata Di Rende, CS, Italy
关键词
Organophosphate flame retardants OPFRs; Experimental design; Microextraction by packed sorbent MEPS; Gas chromatography; Environmental waters; Tandem mass spectrometry; SOLID-PHASE MICROEXTRACTION; POLYBROMINATED DIPHENYL ETHERS; WASTE-WATER SAMPLES; DRINKING-WATER; HUMAN URINE; PLASTICIZERS; ASSAY; EXPOSURE; EXTRACTION; TOXICITY;
D O I
10.1007/s00216-017-0669-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, organophosphate ester flame retardant (OPFRs) assay in environmental waters was addressed by using microextraction by packed sorbent (MEPS) and gas chromatography-tandem mass spectrometry (GC-MS/MS). Ten OPFRs with different physicochemical properties were taken into account as target compounds for a comprehensive method evaluation. Five MEPS cartridges (i.e., C2, C8, C18, Silica, and DVB) and seven solvents (i.e., methanol, ethyl acetate, methyl tert-butyl ether, hexane, acetonitrile, dichloromethane, and trichloromethane) were surveyed. The analysis was performed by using a gas chromatograph equipped with a programmed temperature vaporization injector (PTV). Univariate and multivariate approaches were exploited in order to optimize the parameters affecting the MEPS extraction and the PTV injection of the analytes into the gas chromatographic system. The optimal working conditions were achieved using DVB as sorbent material and acetonitrile as elution solvent. Internal standard calibration was carried out using TBP-d27 and TCEP-d12. Satisfactory values of accuracy and precision were generally obtained as well as limit of detection (2.7-99 pg/mL for tap water; 2.9-97 pg/mL for river water; 3-107 pg/mL for wastewater) and limit of quantification (0.01-0.2 ng/mL). The proposed protocol was evaluated on real case scenarios by analyzing tap water, river water and simulated wastewater samples. The developed method is not only eco-friendly due to the low use of organic solvents but also simple and automatable since the MEPS extraction procedure can be implemented in the autosampler routine.
引用
收藏
页码:7105 / 7120
页数:16
相关论文
共 50 条
  • [1] Multivariate optimization of a microextraction by packed sorbent-programmed temperature vaporization-gas chromatography–tandem mass spectrometry method for organophosphate flame retardant analysis in environmental aqueous matrices
    Attilio Naccarato
    Rosangela Elliani
    Giovanni Sindona
    Antonio Tagarelli
    Analytical and Bioanalytical Chemistry, 2017, 409 : 7105 - 7120
  • [2] Assessment of benzothiazoles, benzotriazoles and benzenesulfonamides in environmental waters using an optimized combination of microextraction by packed sorbent with programmed temperature vaporization-gas chromatography tandem-mass spectrometry
    Elliani, Rosangela
    Tagarelli, Antonio
    Naccarato, Attilio
    TALANTA, 2023, 258
  • [3] A method based on microextraction by packed sorbent-programmed temperature vaporizer–fast gas chromatography–mass spectrometry for the determination of aromatic amines in environmental water samples
    Miguel del Nogal Sánchez
    Cristina Pérez Sappó
    José Luis Pérez Pavón
    Bernardo Moreno Cordero
    Analytical and Bioanalytical Chemistry, 2012, 404 : 2007 - 2015
  • [4] Determination of chlorobenzenes in water samples based on fully automated microextraction by packed sorbent coupled with programmed temperature vaporization-gas chromatography-mass spectrometry
    Grueiro Noche, Gloria
    Fernandez Laespada, Maria Esther
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    Muniategui Lorenzo, Soledad
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (21) : 6739 - 6748
  • [5] Development of a programmed temperature vaporization-gas chromatography-tandem mass spectrometry method for polycyclic aromatic hydrocarbons analysis in biota samples at ultratrace levels
    Fernandez-Gonzalez, V.
    Muniategui-Lorenzo, S.
    Lopez-Mahia, P.
    Prada-Rodriguez, D.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1207 (1-2) : 136 - 145
  • [6] A method based on microextraction by packed sorbent-programmed temperature vaporizer-fast gas chromatography-mass spectrometry for the determination of aromatic amines in environmental water samples
    del Nogal Sanchez, Miguel
    Perez Sappo, Cristina
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) : 2007 - 2015
  • [7] Determination of Organophosphorous Pesticides in Blood Using Microextraction in Packed Sorbent and Gas Chromatography-Tandem Mass Spectrometry
    Santos, C.
    Oppolzer, D.
    Goncalves, A.
    Barroso, M.
    Gallardo, E.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2018, 42 (05) : 321 - 329
  • [8] Determination of opiates in whole blood using microextraction by packed sorbent and gas chromatography-tandem mass spectrometry
    Prata, Margarida
    Ribeiro, Andreia
    Figueirinha, David
    Rosado, Tiago
    Oppolzer, David
    Restolho, Jose
    Araujo, Andre R. T. S.
    Costa, Suzel
    Barroso, Mario
    Gallardo, Eugenia
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 1 - 10
  • [9] Miniaturized extraction method for analysis of synthetic opioids in urine by microextraction with packed sorbent and liquid chromatography-tandem mass spectrometry
    da Cunha, Kelly Francisco
    Rodrigues, Leonardo Costalonga
    Huestis, Marilyn A.
    Costa, Jose Luiz
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624
  • [10] Determination of chlorobenzenes in water samples based on fully automated microextraction by packed sorbent coupled with programmed temperature vaporization–gas chromatography–mass spectrometry
    Gloria Grueiro Noche
    María Esther Fernández Laespada
    José Luis Pérez Pavón
    Bernardo Moreno Cordero
    Soledad Muniategui Lorenzo
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6739 - 6748