Comparative Analysis of Radiographic Hip Joint Geometry Using Measurement Tools on Picture Archiving and Communication System: A Prospective Study of 100 Pelvic Radiographs of Koreans

被引:10
|
作者
Kim, Seung-Chan [1 ]
Lim, Young-Wook [1 ]
Kwon, Soon-Yong [2 ]
Lee, Jun-Ku [1 ]
Park, Il-Kyu [1 ]
Kim, Yong-Sik [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Orthopaed Surg, Banpodae Ro 222, Seoul 137701, South Korea
[2] Catholic Univ Korea, Coll Med, Yeouido St Marys Hosp, Dept Orthopaed Surg, Seoul, South Korea
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 11期
关键词
geometry; hip joint geometry; picture archiving and communication system; bilateral variation; hip arthroplasty; LEG LENGTH DISCREPANCY; ABDUCTOR MUSCLE STRENGTH; QUALITY-OF-LIFE; FEMORAL OFFSET; ARTHROPLASTY; REPLACEMENT; AGREEMENT; PRECISION; ACCURACY; MOTION;
D O I
10.1016/j.arth.2016.04.038
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A contralateral normal hip joint has been often used as a reference standard in preoperative planning and intraoperative assessment of hip arthroplasty, with the assumption that bilateral hip joint geometries have no significant differences. However, one previous study using analog measurements on hardcopy films reported significant bilateral variation in hip joint geometry. We therefore investigated the level of agreement between the right and left hips for each measurement and determined index values and the range of normal bilateral variations. Methods: We assessed 100 standard anteroposterior radiographs of the pelvis in this study. Two independent observers measured the actual value of femoral head diameter, location of the femoral head center, acetabular offset, femoral offset, hip offset, greater trochanteric height, neck-shaft angle, medullary canal diameter, and proximal femoral diameter. Intraclass correlation coefficients (ICCs) and values of mean difference were calculated for each measurement. Results: The results demonstrated perfect agreement (ICC >0.8) between the right and left hips for most parameters and substantial agreement for greater trochanteric height (ICC = 0.735) and femoral offset (ICC = 0.773). The mean difference and standard deviation in the measurement between the right and left hips for the location of the femoral head center and the acetabular offset were 0.60 +/- 0.48 mm and 0.42 +/- 0.30 mm, respectively. Conclusion: Hip joint geometry is not influenced by side. In hip arthroplasty, a contralateral normal hip can be reliably used as a guide for preoperative planning using measurement tools on a picture archiving and communication system. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:2597 / 2602
页数:6
相关论文
共 2 条
  • [1] A Reliability Study of Measurement Tools Available on Standard Picture Archiving and Communication System Workstations for the Evaluation of Hip Radiographs Following Arthroplasty
    Patel, Sanjay R.
    Toms, Andoni P.
    Rehman, Javed M.
    Wimhurst, James
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (18): : 1712 - 1719
  • [2] Spondylolisthesis: Intra-rater and inter-rater reliabilities of radiographic sagittal spinopelvic parameters using standard picture archiving and communication system measurement tools
    Montgomery R.A.
    Hresko M.T.
    Kalish L.A.
    Gold M.
    Li Y.
    Haus B.
    Glotzbecker M.
    Berthonnaud E.
    Spine Deformity, 2013, 1 (6) : 412 - 418