Diffusion-weighted breast magnetic resonance imaging with distortion correction using non-rigid image registration: a clinical study

被引:3
|
作者
Takatsu, Yasuo [1 ,2 ]
Sagawa, Hajime [3 ]
Nakamura, Masafumi [4 ]
Suzuki, Yuichi [5 ]
Miyati, Tosiaki [2 ]
机构
[1] Tokushima Bunri Univ, Fac Hlth & Welf, Dept Radiol Technol, 1314-1 Shido, Sanuki, Kagawa 7692193, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kyoto Univ Hosp, Div Clin Radiol Serv, Sakyo Ku, 54 Kawaharacho, Kyoto 6068507, Japan
[4] Otsu City Hosp, Dept Radiol, 2-9-9 Motomiya, Otsu, Shiga 5200804, Japan
[5] Univ Tokyo Hosp, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138655, Japan
关键词
Magnetic resonance imaging; Diffusion-weighted image; Breast; Distortion correction; Non-rigid image registration; REDUCTION;
D O I
10.1007/s12194-020-00568-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our distortion correction method for diffusion-weighted breast images was applied to clinical studies to evaluate its practicality. We used b values of 0 and 1500 s/mm(2) and dynamic images captured after injecting the contrast medium for magnetic resonance imaging (MRI). This method is based on non-rigid image registration, and dispenses with multiple scans, reducing examination time and patient burden. Image correction included the following: matrix size matching; segmentation; edge detection; non-rigid image registration between T2-weighted images with fat suppression and b0 images; and image warping of b1500 images. Significant differences were noted for all combinations of cross-correlation coefficients of whole-breast images between with and without correction, and no significant differences for apparent diffusion coefficients. The percentage differences were not significant for cross-correlation coefficients, with and without correction, calculated for various sizes, positions, and types of lesions of high-intensity regions. In conclusion, our distortion correction method is effective for clinical breast MRI.
引用
收藏
页码:210 / 218
页数:9
相关论文
共 50 条
  • [1] Diffusion-weighted breast magnetic resonance imaging with distortion correction using non-rigid image registration: a clinical study
    Yasuo Takatsu
    Hajime Sagawa
    Masafumi Nakamura
    Yuichi Suzuki
    Tosiaki Miyati
    [J]. Radiological Physics and Technology, 2020, 13 : 210 - 218
  • [2] Novel distortion correction method for diffusion-weighted imaging based on non-rigid image registration between low b value image and anatomical image
    Takatsu, Yasuo
    Sagawa, Hajime
    Nakamura, Masafumi
    Suzuki, Yuichi
    Miyati, Tosiaki
    [J]. MAGNETIC RESONANCE IMAGING, 2019, 57 : 277 - 284
  • [3] Motion-Corrected versus Conventional Diffusion-Weighted Magnetic Resonance Imaging of the Liver Using Non-Rigid Registration
    Son, Je Seung
    Park, Hee Sun
    Park, Sungeun
    Kim, Young Jun
    Yu, Mi Hye
    Jung, Sung Il
    Paek, Munyoung
    Nickel, Marcel Dominik
    [J]. DIAGNOSTICS, 2023, 13 (06)
  • [4] Distortion correction via non-rigid registration of functional to anatomical magnetic resonance brain images
    Gholipour, Ali
    Kehtarnavaz, Nasser
    Gopinath, Kaundinya
    Briggs, Richard
    Devous, Michael
    Haley, Robert
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 1181 - +
  • [5] Breast Magnetic Resonance Imaging: Diffusion-Weighted Imaging
    Brandao, Alice C.
    Lehman, Constance D.
    Partridge, Savannah C.
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2013, 21 (02) : 321 - +
  • [6] DIFFUSION WEIGHTED IMAGING DISTORTION CORRECTION USING HYBRID MULTIMODAL IMAGE REGISTRATION
    Lu, Huanxiang
    Cattin, Philippe C.
    Nolte, Lutz-Peter
    Reyes, Mauricio
    [J]. 2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 594 - 597
  • [7] Distortion correction of diffusion-weighted magnetic resonance imaging of the head and neck in radiotherapy position
    Winter, Rene M.
    Schmidt, Holger
    Leibfarth, Sara
    Zwirner, Kerstin
    Welz, Stefan
    Schwenzer, Nina F.
    la Fougere, Christian
    Nikolaou, Konstantin
    Gatidis, Sergios
    Zips, Daniel
    Thorwarth, Daniela
    [J]. ACTA ONCOLOGICA, 2017, 56 (11) : 1659 - 1663
  • [8] Non-rigid registration of magnetic resonance imaging of brain.
    Chesseboeuf, Clement
    Bierme, Hermine
    Dambrine, Julien
    Guillevin, Carole
    Guillevin, Remy
    [J]. 5TH INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, THEORY, TOOLS AND APPLICATIONS 2015, 2015, : 385 - 390
  • [9] A Preliminary Study of the Geometric Distortion in Diffusion-Weighted Imaging of Magnetic Resonance Imaging Simulation
    Liu, X.
    Qiu, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E510 - E510
  • [10] A Preliminary Study of the Geometric Distortion in Diffusion-Weighted Imaging of Magnetic Resonance Imaging Simulation
    Liu, X.
    Qiu, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E328 - E329