New-generation diabetes management: glucose sensor-augmented insulin pump therapy

被引:0
|
作者
Cengiz, Eda [1 ]
Sherr, Jennifer L. [1 ]
Weinzimer, Stuart A. [1 ]
Tamborlane, William V. [1 ]
机构
[1] Yale Univ, Sch Med, New Haven, CT 06520 USA
基金
美国国家卫生研究院;
关键词
artificial pancreas; closed-loop; continuous glucose monitors; continuous subcutaneous insulin infusion; diabetes; sensor-augmented pump therapy; MONITORING-SYSTEM; BLOOD-GLUCOSE; PEDIATRIC-PATIENTS; INFUSION; CHILDREN; ACCURACY; ADOLESCENTS; LOOP; HYPOGLYCEMIA; PERFORMANCE;
D O I
10.1586/ERD.11.22
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 50 条
  • [1] Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
    Kerr, David
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (21): : 2070 - 2071
  • [2] Analysis of Glucose Responses to Automated Insulin Suspension With Sensor-Augmented Pump Therapy
    Ly, Trang T.
    Nicholas, Jennifer A.
    Retterath, Adam
    Davis, Elizabeth A.
    Jones, Timothy W.
    [J]. DIABETES CARE, 2012, 35 (07) : 1462 - 1465
  • [3] Application of a sensor-augmented insulin pump in management of blood glucose in patients with type 1 diabetes mellitus
    Peng, Lanbo
    Tian, Yaqiang
    Sun, Jie
    Li, Ming
    Duan, Honggang
    Shen, Yanjun
    Li, Ying
    Song, Guangyao
    [J]. DIABETES-METABOLISM RESEARCH AND REVIEWS, 2016, 32 (SUPP 2) : 38 - 39
  • [4] A PERSPECTIVE OF SENSOR-AUGMENTED INSULIN PUMP THERAPY IN THE TREATMENT OF TYPE 1 DIABETES
    Rayfield, Elliot J.
    [J]. ENDOCRINE PRACTICE, 2015, 21 (01) : 91 - 92
  • [5] Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes REPLY
    Bergenstal, Richard M.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (21): : 2071 - 2071
  • [6] Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
    Bergenstal, Richard M.
    Tamborlane, William V.
    Ahmann, Andrew
    Buse, John B.
    Dailey, George
    Davis, Stephen N.
    Joyce, Carol
    Peoples, Tim
    Perkins, Bruce A.
    Welsh, John B.
    Willi, Steven M.
    Wood, Michael A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04): : 311 - 320
  • [7] Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    Jecht, M.
    [J]. DIABETOLOGE, 2010, 6 (06): : 486 - 487
  • [8] Sensor-augmented pump therapy in type 1 diabetes
    Weinzimer, Stuart A.
    Tamborlane, William V.
    [J]. CURRENT OPINION IN ENDOCRINOLOGY DIABETES AND OBESITY, 2008, 15 (02) : 118 - 122
  • [9] Provider Time Associated with Sensor-Augmented Insulin Pump Therapy in Type 1 Diabetes
    Kamble, Shital
    Perry, Brenda M.
    Shafiroff, Jeff
    Schulman, Kevin A.
    Reed, Shelby D.
    [J]. DIABETES, 2011, 60 : A238 - A238
  • [10] Patient experiences of continuous glucose monitoring and sensor-augmented insulin pump therapy for diabetes: A systematic review of qualitative studies
    Natale, Patrizia
    Chen, Sharon
    Chow, Clara K.
    Cheung, Ngai Wah
    Martinez-Martin, David
    Caillaud, Corinne
    Scholes-Robertson, Nicole
    Kelly, Ayano
    Craig, Jonathan C.
    Strippoli, Giovanni
    Jaure, Allison
    [J]. JOURNAL OF DIABETES, 2023, 15 (12) : 1048 - 1069