Differential Reconstruction Method for Power Frequency AC Current Measurement Using Rogowski Coil

被引:19
|
作者
Ibrahim, Mohamed E. [1 ]
Abd-Elhady, Amr M. [1 ]
机构
[1] Menoufia Univ, Fac Engn, High Voltage & Dielect Mat Lab, Shibin Al Kawm 32511, Egypt
关键词
AC current; differential reconstruction; power frequency; Rogowski coil;
D O I
10.1109/JSEN.2016.2614352
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a developed method for measuring power frequency ac current using Rogowski coil is presented. The proposed method uses a differentiator in order to reconstruct the current that is intended to be measured. This method gives accurate results as well as it requires only few samples to successfully reconstruct the power frequency current. These advantages are investigated by experimental testing using two different designs of Rogowski coil. The first Rogowski coil has a higher number of turns as compared with the second one. In addition, a digital signal processor is integrated with the coil to implement the proposed reconstruction method. The obtained results give an evidence for the proposed method validity as well as its efficacy.
引用
收藏
页码:8420 / 8425
页数:6
相关论文
共 50 条
  • [1] Influence of busbar geometry on AC current measurement using Rogowski coil
    Chekurov, Y.
    Hallstrom, J.
    [J]. 2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 542 - 543
  • [2] Power frequency AC voltage measurement based on double wound Rogowski coil
    Ibrahim, Mohamed E.
    Abd-Elhady, Amr M.
    [J]. HIGH VOLTAGE, 2017, 2 (02): : 129 - 135
  • [3] Measurement of Power Frequency Current including Low- and High-Order Harmonics Using a Rogowski Coil
    El-Shahat, Mohammed
    Eldin, Elsayed Tag
    Mohamed, Nourhan A.
    El-Morshedy, Ahdab
    Ibrahim, Mohamed E.
    [J]. SENSORS, 2022, 22 (11)
  • [4] Measurement of pulse heavy current in coil launcher using Rogowski coil
    Zhang, CW
    Li, ZY
    Hu, JL
    Jiang, GC
    Duan, XJ
    [J]. ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 1, 2005, : 160 - 163
  • [5] Lightning Current Measurement Method Using Rogowski Coil Based on Integral Circuit with Low-Frequency Attenuation Feedback
    Xiao, Yiping
    Jiao, Hongjian
    Huo, Feng
    Shen, Zongtao
    [J]. SENSORS, 2024, 24 (15)
  • [6] Rogowski Coil for Current Measurement in a Cryogenic Environment
    Ma, Tao
    Dai, Shaotao
    Zhang, Jingye
    Zhao, Lianqi
    [J]. MEASUREMENT SCIENCE REVIEW, 2015, 15 (02): : 77 - 84
  • [7] Heavy current measurement based on Rogowski coil
    Dai, Jianhua
    Li, Kaicheng
    [J]. Gaodianya Jishu/High Voltage Engineering, 2002, 28 (01):
  • [8] FREQUENCY RESPONSE ANALYSIS OF A ROGOWSKI COIL TRANSDUCER FOR RAILGUN PULSE CURRENT MEASUREMENT
    Wang, D. Y.
    Wang, Z. C.
    Sun, X. F.
    Wang, B. C.
    [J]. 2015 IEEE PULSED POWER CONFERENCE (PPC), 2015,
  • [9] Measurement of pulsed heavy current in rail launcher using Rogowski coil
    Zhang, CW
    Li, ZY
    Hu, JL
    Yang, JH
    [J]. ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 2800 - 2803
  • [10] Measurement of power frequency AC current using FBG and GMM
    Hong, Z
    Xiong, YL
    Jian, Z
    Wang, SR
    [J]. PROCEEDINGS OF THE 2005 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, VOLS, 1-3, 2005, : 741 - 743