Method for Reducing Windmill Artifacts in Multi-Slice CT Images

被引:1
|
作者
Brown, Kevin M. [1 ]
Zabic, Stanislav [1 ]
机构
[1] Philips Healthcare, Cleveland, OH 44143 USA
关键词
CT; Reconstruction;
D O I
10.1117/12.877437
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thin-slice images reconstructed from helical multi-slice CT scans typically display artifacts known as windmill artifacts, which arise from not satisfying the Nyquist sampling criteria in the patient longitudinal direction. Since these are essentially aliasing artifacts, they can be reduced or removed by trading off resolution, either globally (by reconstructing thicker slices) or locally (by local smoothing of the strong gradients). The obvious drawback to this approach is the associated loss in resolution. Another approach is to utilize an x-ray tube with the capability to modulate the focal spot in the z-direction, to effectively improve the sampling rate. This work presents a new method for windmill artifact reduction based on total variation minimization in the image domain, which is capable of removing windmill artifacts while at the same time preserving the resolution of anatomic structures within the images. This is a big improvement over previous reconstruction methods that sacrifice resolution, and it provides practically the same benefits as a z-switching x-ray tube with a much simpler impact to the overall CT system.
引用
下载
收藏
页数:5
相关论文
共 50 条
  • [1] Windmill artifact in multi-slice helical CT
    Silver, M
    Taguchi, K
    Hein, I
    Chiang, BS
    Kazama, M
    Mori, I
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1918 - 1927
  • [2] Quantification and elimination of windmill artifacts in multi slice CT
    Utrup, Steven J.
    Brown, Kevin M.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [3] Multi-slice CT artifacts and quality control
    Cody, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2178 - 2178
  • [4] Method for segmentation of pulmonary nodules on multi-slice CT images
    Neusoft Research, Shenyang 110179, China
    不详
    Tien Tzu Hsueh Pao, 2006, SUPPL. (2478-2480):
  • [5] Characterization of motion artifacts in multi-slice spiral CT
    Graf, H
    Heuschmid, M
    Küttner, A
    Kopp, AF
    Claussen, CD
    Schick, F
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1301 - 1308
  • [6] Extraction method of interlobar fissure based on multi-slice CT images
    Matsuhiro, M.
    Suzuki, H.
    Kawata, Y.
    Niki, N.
    Ueno, J.
    Nakano, Y.
    Ogawa, E.
    Muro, S.
    Mishima, M.
    Ohmatsu, H.
    Moriyama, N.
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [7] Volumetric segmentation of lung lobes on multi-slice CT images
    Saita, S
    Kawata, Y
    Niki, N
    Ohmatsu, H
    Kakinuma, R
    Moriyama, N
    RADIOLOGY, 2002, 225 : 499 - 499
  • [8] Peripleural lung disease detection based on multi-slice CT images
    Matsuhiro, M.
    Suzuki, H.
    Kawata, Y.
    Niki, N.
    Nakano, Y.
    Ohmatsu, H.
    Kusumoto, M.
    Tsuchida, T.
    Eguchi, K.
    Kaneko, M.
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [9] Computer aided diagnosis of osteoporosis using multi-slice CT images
    Institute of Technology and Science, University of Tokushima, 2-1 Minamijosanjima-cho, Tokushima-shi, Tokushima
    770-8506, Japan
    不详
    852-8501, Japan
    不详
    770-0042, Japan
    不详
    104-0045, Japan
    Progr. Biomed. Opt. Imaging Proc. SPIE,
  • [10] Computer Aided Diagnosis for Osteoporosis Using Multi-slice CT images
    Takahashi, Eiji
    Saita, Shinsuke
    Kawata, Yoshiki
    Niki, Noboru
    Ito, Masako
    Nishitani, Hiromu
    Moriyama, Noriyuki
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624