Miniature bending manipulator for fetoscopic intrauterine laser therapy to treat twin-to-twin transfusion syndrome

被引:26
|
作者
Yamashita, H. [1 ]
Matsumiya, K. [1 ]
Masamune, K. [1 ]
Liao, H. [2 ]
Chiba, T. [3 ]
Dohi, T. [1 ]
机构
[1] Univ Tokyo, Grad Sch Informat Sci & Technol, Dept Mechano Informat, Bunkyo Ku, Tokyo 113, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Precis Engn, Tokyo 1138656, Japan
[3] Natl Ctr Child Hlth & Dev, Dept Strateg Med, Setagaya Ku, Tokyo 1578535, Japan
关键词
miniature bending manipulator; selective laser photocoagulation; twin-to-twin transfusion syndrome;
D O I
10.1007/s00464-007-9444-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Recent typical therapy for twin-to-twin transfusion syndrome (TTTS) is selective laser photocoagulation of anastomotic communicating vessels on the placenta using the fetoscopic approach. The difficulty of a conventional laser device approach for this procedure depends significantly on the placental location, so a new robotized device is required to bend the direction of laser irradiation flexibly within the narrow uterus. Methods The authors designed a miniature bending mechanism impelled by a wire-guided linkage driving method that provides a stable procedure for bending laser irradiation from -90 degrees to 90 degrees. Using this bending mechanism, the authors developed a bending manipulator with a diameter of 3.5 mm and a hollow central channel with a diameter of 0.8 mm for passing a glass fiber for neodymium:yttrium-aluminum-garnet (Nd:YAG) laser photocoagulation. The bending mechanism is motorized by an electrical actuator and controlled by a grip-type interface with a small joystick. The robotized tip's part and the actuator's part are easily separable for cleaning and sterilization. Results In performance evaluations of the manipulator, the bending characteristics with a glass fiber were examined. The bending range was -52.6 degrees to 80 degrees, with a very small hysteresis error, and the bending repeatability error was 0.5 degrees +/- 0.2 degrees, which corresponds with the high accuracy of 0.2 +/- 0.1-mm positioning error at the glass fiber's tip. In the evaluation of Nd:YAG laser photocoagulation, the study confirmed that the manipulator performed effective laser photocoagulation of the placental phantom surface (underwater chicken liver). The large bending range, reaching 80 degrees, enabled a flexible approach from various directions with a high irradiation efficiency of no less than 96.6%. Conclusions The authors' original miniature bending manipulator can change the laser irradiating direction with highly repeatable positioning accuracy for speedy, safe, and effective vessel occlusion in clinical practice.
引用
收藏
页码:430 / 435
页数:6
相关论文
共 50 条
  • [1] Miniature bending manipulator for fetoscopic intrauterine laser therapy to treat twin-to-twin transfusion syndrome
    H. Yamashita
    K. Matsumiya
    K. Masamune
    H. Liao
    T. Chiba
    T. Dohi
    [J]. Surgical Endoscopy, 2008, 22 : 430 - 435
  • [2] Fetoscopic laser therapy for twin-to-twin transfusion syndrome
    Khalek, Nahla
    Johnson, Mark P.
    Bebbington, Michael W.
    [J]. SEMINARS IN PEDIATRIC SURGERY, 2013, 22 (01) : 18 - 23
  • [3] Effects and outcomes of septostomy in twin-to-twin transfusion syndrome after fetoscopic laser therapy
    Li, Wen-Fang
    Chao, An-Shine
    Chang, Shuenn-Dyh
    Cheng, Po-Jen
    Yang, Lan-Yan
    Chang, Yao-Lung
    [J]. BMC PREGNANCY AND CHILDBIRTH, 2019, 19 (01)
  • [4] Effects and outcomes of septostomy in twin-to-twin transfusion syndrome after fetoscopic laser therapy
    Wen-Fang Li
    An-Shine Chao
    Shuenn-Dyh Chang
    Po-Jen Cheng
    Lan-Yan Yang
    Yao-Lung Chang
    [J]. BMC Pregnancy and Childbirth, 19
  • [5] Fetoscopic laser ablation in twin-to-twin transfusion syndrome: tips for counselling
    Pajno, Cristina
    D'Ambrosio, Valentina
    D'Alisa, Rossella
    di Mascio, Daniele
    Vena, Flaminia
    Corno, Sara
    Spiniello, Lorenzo
    Martinino, Alessandro
    Manicone, Francesca
    Muzii, Ludovico
    Brunelli, Roberto
    Giancotti, Antonella
    [J]. MINERVA OBSTETRICS AND GYNECOLOGY, 2021, 73 (02) : 247 - 252
  • [6] Fetoscopic laser coagulation in twin-to-twin transfusion syndrome: The learning curve
    Peeters, Suzanne
    Oepkes, Dick
    Lopriore, Enrico
    Klumper, Frans
    Vandenbussche, Frank
    Middeldorp, Annemieke
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 197 (06) : S162 - S162
  • [7] Distance Measuring Navigation for Fetoscopic Laser Photocoagulation to Treat Twin-to-Twin Transfusion Syndrome: Feasibility Evaluations
    Yamashita, H.
    Yamashita, T.
    Masamune, K.
    Liao, H.
    Kim, K.
    Chiba, T.
    Dohi, T.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 197 - +
  • [8] Neonatal Outcome in Twin-to-Twin Transfusion Syndrome Not Treated with Fetoscopic Laser Surgery
    Lopriore, Elina A.
    Slaghekke, Femke
    Verweij, E. Joanne
    Haak, Monique C.
    Middeldorp, Annemieke J. M.
    Lopriore, Enrico
    [J]. TWIN RESEARCH AND HUMAN GENETICS, 2022, 25 (01) : 45 - 49
  • [9] Role of psychological intervention in fetoscopic laser surgery of twin-to-twin transfusion syndrome
    Li, L. X.
    Gao, Y.
    Xu, S. L.
    [J]. CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2013, 40 (04): : 561 - 564
  • [10] Laser therapy for twin-to-twin transfusion syndrome (TTTS)
    Chalouhi, G. E.
    Essaoui, M.
    Stirnemann, J.
    Quibel, T.
    Deloison, B.
    Salomon, L.
    Ville, Y.
    [J]. PRENATAL DIAGNOSIS, 2011, 31 (07) : 637 - 646