Gated cone-beam CT imaging of the thorax: A reconstruction study

被引:0
|
作者
Rit, Simon [1 ]
Sarrut, David [2 ,3 ]
Miguet, Serge [1 ]
机构
[1] Univ Lyon 2, LIRIS, 5 Ave Pierre Mendes-France, F-69676 Bron, France
[2] Inst Natl Sci Appl, CREATIS, F-69621 Villeurbanne, France
[3] Ctr Leon Berard, Dept Radiotherapy, F-69353 Lyon, France
关键词
reconstruction; computed tomography (CT); phantom; thorax; gated; dynamic;
D O I
10.1117/12.707623
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In radiotherapy, the respiratory motion of the patient in treatment position is determined from gated cone-beam CT images. This method consists in selecting projections according to a respiratory signal for the reconstruction of a CT image of each respiratory state. This selection can be based on the amplitude or the phase of the signal. The number of selected projections also depends on the width of the gating window. The present study compares different reconstructions using a dynamic digital phantom of the thorax and a known respiratory signal. We applied both regular and irregular motions to this phantom and reconstructed the exhale state using different widths. We evaluated these reconstructions with the signal-to-noise ratio, the contrast-to-noise ratio and a blur criterion. In the case of a regular motion, there was no difference between the amplitude and the phase. The signal quality was high, even for the smallest width, and the blur increased with width. In the case of an irregular motion, the difference was noticeable. Amplitude-based reconstructions suffered from severe artifacts with the smallest width because there were respiratory cycles for which no projection was selected. This drawback is overcome by increasing the width of the gating window. Phase-based reconstructions also allowed to avoid artifacts, whatever the width. But the blur was higher, even for the smallest width applied. These results suggest that the gating process must be adjusted in order to select at least one projection per respiratory cycle. Phase gating is a robust way to achieve this goal when respiration is irregular. Amplitude gating may be more effective in terms of blur, but the width must be carefully chosen to avoid severe artifacts. Finally, we observed the potential of dynamic reconstruction by using a motion model to deform different gated CT images toward a common reference and compute the weighted mean. The resulting CT image suffered less from artifacts than each gated CT image separately even if artifacts were still visible.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Cone-beam CT angiography of the thorax - An experimental study
    Yoshida, K
    Tadokoro, H
    Shimada, K
    Endo, M
    Satoh, K
    Kitsukawa, S
    Takami, A
    Masuda, Y
    Kusakabe, M
    Sasaki, Y
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (10): : 789 - 793
  • [2] Respiratory gated cone-beam CT volumetric imaging for external beam radiotherapy
    Moseley, DJ
    Hawkins, M
    Eccles, C
    Euler, C
    White, EA
    Bissonnette, J
    Dawson, LA
    Jaffray, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S27 - S28
  • [3] Influence of respiratory motion on cone-beam CT (CBCT) imaging of thorax and abdomen
    Kim, G
    Li, T
    Yang, Y
    Schreibmann, E
    Thorndyke, B
    Boyer, A
    Xing, L
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1934 - 1934
  • [4] Investigation of Gated Cone-Beam CT to Reduce Respiratory Motion Blurring in Images of Thorax and Abdomen
    Kincaid, R.
    Yorke, E.
    Goodman, K.
    Rimner, A.
    Wu, A.
    Mageras, G.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3904 - 3904
  • [5] Cone-beam CT based dose calculation in the thorax region
    Kaplan, L. P.
    Hoffmann, L.
    Moller, D. S.
    Elstrom, U. V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S210 - S211
  • [6] Comparison of Analytic and Algebraic Methods for Motion-Compensated Cone-Beam CT Reconstruction of the Thorax
    Rit, Simon
    Sarrut, David
    Desbat, Laurent
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) : 1513 - 1525
  • [7] Exact Interior Reconstruction with Cone-Beam CT
    Ye, Yangbo
    Yu, Hengyong
    Wang, Ge
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2007, 2007
  • [8] Iterative cardiac cone-beam CT reconstruction
    Nielsen, T
    Manzke, R
    Koehler, T
    Grass, M
    Proksa, R
    [J]. MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2003 - 2014
  • [9] Cone-beam CT reconstruction for planar object
    Liu, Tong
    [J]. NDT & E INTERNATIONAL, 2012, 45 (01) : 9 - 15
  • [10] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387