Monte Carlo simulations for therapy imaging

被引:6
|
作者
Ljungberg, M. [1 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
关键词
SPECT; SCATTER; PHANTOM;
D O I
10.1088/1742-6596/317/1/012016
中图分类号
O59 [应用物理学];
学科分类号
摘要
In therapy imaging there is a need to optimize imaging protocols and different correction methods for e.g. photon attenuation, contribution from scatter and other physics-related effects that limits the possibility to achieve accurate quantitative results. Physical phantom studies are important but lack flexibility and are often difficult to make patient realistic. A complement is to simulate the study using a Monte Carlo-based model of the imaging process including accurate description of the interaction processes and a realistic model of the patient and the imaging device. With the Monte Carlo method it is also possible to simulate and calculate parameters that otherwise would be impossible to measure from a physical experiment. An example of such is the simulation of a scatter and an attenuation-free situation. Results from such simulations can be very important in a validation procedure serving as reference data for which results obtained by different correction methods can be compared to. The Monte Carlo method has also been used to calculate absorbed doses from reference phantom or patient-specific phantom obtained from a CT study. This paper give an overview of the method and show examples of how Monte Carlo simulation can be used to evaluate therapy imaging with different radionuclides but also how simulations can be used for calculation of necessary parameters for correction of scatter, attenuation and collimator response.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Monte Carlo simulations of a proton therapy beamline
    Soukup, M
    Weber, A
    Heufelder, J
    Fippel, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S160 - S160
  • [2] Monte Carlo simulations in small animal PET imaging
    Branco, Susana
    Jan, Sebastien
    Almeida, Pedro
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1127 - 1130
  • [3] Feasibility of Monte Carlo simulations in quantitative tissue imaging
    Maeder, Ulf
    Schmidts, Thomas
    Avci, Ersin
    Heverhagen, Johannes T.
    Runkel, Frank
    Fiebich, Martin
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (04): : 253 - 259
  • [4] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305
  • [5] Monte Carlo methods for device simulations in radiation therapy
    Park, Hyojun
    Paganetti, Harald
    Schuemann, Jan
    Jia, Xun
    Min, Chul Hee
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [6] Automation of Monte Carlo simulations for a proton therapy system
    Zheng, Y.
    Newhauser, W.
    Fontenot, J.
    Koch, N.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2073 - 2074
  • [7] Monte Carlo simulations
    Dapor, M
    [J]. ELECTRON-BEAM INTERACTIONS WITH SOLIDS: APPLICATION OF THE MONTE CARLO METHOD TO ELECTRON SCATTERING PROBLEMS, 2003, 186 : 69 - 90
  • [8] Validation of gate Monte Carlo simulations for indium 111 imaging
    Assié, K
    Gardin, I
    Véra, P
    Buvat, I
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4023 - 4027
  • [9] Diffraction enhanced breast imaging through Monte Carlo simulations
    Cunha, D. M.
    Tomal, A.
    Poletti, M. E.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 878 - 882
  • [10] Monte Carlo simulations of arterial imaging with optical coherence tomography
    Amendt, P
    Estabrook, K
    Everett, M
    London, RA
    Maitland, D
    Zimmerman, G
    Colston, B
    Da Silva, L
    Sathyam, U
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 202 - 213