Marine Power Distribution System Fault Location Using a Portable Injection Unit

被引:24
|
作者
Jia, Ke [1 ]
Bi, Tianshu [2 ]
Liu, Bohan [3 ]
Christopher, Edward [4 ]
Thomas, David W. P. [4 ]
Sumner, Mark [4 ]
机构
[1] North China Elect Power Univ, Elect & Elect Engn Dept, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing 102206, Peoples R China
[3] HVAC, Natl State Grid, Beijing 100082, Peoples R China
[4] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
基金
中国国家自然科学基金;
关键词
Active impedance estimation; fault location; injections; marine distribution system; IMPEDANCE MEASUREMENT; QUALITY;
D O I
10.1109/TPWRD.2014.2364259
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A portable injection unit for active impedance estimation (AIE) is built and tested in a dc zonal marine power distribution system to provide useful information for system protection and restoration. The portable unit generates current "spikes" and injects them into the system once short-circuit faults are detected (by measuring the system voltage drop). The faulted system impedance can be estimated by AIE and comparing the estimated impedance with the precalibrated value, the fault location can be determined. The proposed method does not rely on system fault transient information or communication from the remote-end measurement and offers fast and accurate fault location in dc marine distribution systems. The proposed method has been tested and validated on a 750-V, 2-MW twin bus dc commercial test facility with the system de-energized and energized.
引用
收藏
页码:818 / 826
页数:9
相关论文
共 50 条
  • [1] Fault Location in DC Marine Power System Using Multiple Injections
    Jia, Ke
    Christopher, Edward
    Sumner, Mark
    Thomas, David
    [J]. INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [2] Fault Location in a Zonal DC Marine Power System using Active Impedance Estimation
    Christopher, Edward
    Sumner, Mark
    Thomas, David
    Wang, Xiaohui
    de Wiidt, Frans
    [J]. 2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 3050 - 3054
  • [3] Fault Location in a Zonal DC Marine Power System Using Active Impedance Estimation
    Christopher, Edward
    Sumner, Mark
    Thomas, David W. P.
    Wang, Xiaohui
    de Wildt, Frans
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (02) : 860 - 865
  • [4] Integrated Fault Location System for Power Distribution Feeders
    Gong, Yanfeng
    Guzman, Armando
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (03) : 1071 - 1078
  • [5] Integrated Fault Location System for Power Distribution Feeders
    Gong, Yanfeng
    Guzman, Armando
    [J]. 2012 IEEE RURAL ELECTRIC POWER CONFERENCE (REPC), 2012,
  • [6] Overview of an Automatic Distribution Fault Location System using Power Quality Monitors
    Sabin, Daniel D.
    Olechiw, Wieslaw Jerry
    Romero, Elder
    Manning, Robert
    Waclawiak, Marek
    [J]. 2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 502 - 506
  • [7] Fault location index for distribution power system restoration using voltage sags
    Fiaschetti, Leandro
    Risso, Mariano
    Boroni, Gustavo
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (01)
  • [8] A novel fault location scheme for power distribution system based on injection method and transient line voltage
    Huang, Yuehua
    Li, Xiaomin
    Cheng, Jiangzhou
    Nie, Deyu
    Wang, Zhuoyuan
    [J]. INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2017), 2018, 121
  • [9] Fault Location in Power Distribution System With Penetration of Distributed Generation
    Brahma, Sukumar M.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) : 1545 - 1553
  • [10] Fault Location for DC Marine Power Systems
    Thomas, David
    Sumner, Mark
    Coggins, David
    Wang, Xiaohui
    Wang, Jing
    Geertsma, Lt Rinze
    [J]. 2009 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM, 2009, : 456 - +