Advanced radiation imaging of low-intensity gamma-ray sources

被引:36
|
作者
Woodring, M
Souza, D
Tipnis, S
Waer, P
Squillante, M
Entine, C
Ziock, KP
机构
[1] Radiat Monitoring Devices Inc, Instrument Res & Dev Grp, Watertown, MA 02172 USA
[2] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
关键词
D O I
10.1016/S0168-9002(98)01022-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging gamma-ray sources and distributions of low intensity is difficult using current commercially available radiation imagers, Radiation Monitoring Devices, Inc. has carried out the research and development necessary to construct a novel, compact radiation-imaging device, RADCAM, for low-intensity applications. The device consists of a position-sensitive photomultiplier tube (PSPMT) coupled to a CsI(Na) scintillation crystal, which is an excellent candidate for such applications due to its high light output. A tungsten coded-aperture mask, placed in front of the scintillator, creates a gamma-ray intensity pattern across the face of the crystal. The PSPMT detects the resulting scintillation pattern and the analog output signals are captured and converted to digital signals by the RMD PSPMT interface card. The digital data is stored and processed by a portable personal computer. The gamma-ray "shadowgram" is then mathematically decoded to yield the original source image. The pseudo-color radiation-source image is overlaid on a video picture of the same area captured by a high-resolution CCD. The combined image is displayed on screen as an accurate map of radioactive gamma-ray sources in the physical environment. Data acquisition and image display are controlled by the IMager Acquisition and Graphical-user-interface Environment (IMAGE), a Windows-NT program developed for the imager. (C) 1999 Published by Elsevier Science B.V. All Fights reserved.
引用
收藏
页码:709 / 712
页数:4
相关论文
共 50 条
  • [1] Neutron beam design for low-intensity neutron and gamma-ray radioscopy using small neutron sources
    Matsumoto, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 346 - 348
  • [2] Advanced multi-dimensional imaging of gamma-ray radiation
    Woodring, M
    Beddingfield, D
    Souza, D
    Entine, G
    Squillante, M
    Christian, J
    Kogan, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 415 - 419
  • [3] DOSE-RATE DEPENDENT DOSIMETER FOR LOW-INTENSITY GAMMA-RAY FIELDS
    OBRIEN, K
    SOLON, LR
    LOWDER, WM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (12): : 1097 - 1100
  • [4] STEREOSCOPIC IMAGING OF GAMMA-RAY SOURCES
    MCINTYRE, JA
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 708 - 708
  • [5] Gamma-ray intensity modulated radiation therapy
    Fox, C.
    Aleman, D.
    Romeijn, H. E.
    Li, J. G.
    Dempsey, J. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S673 - S674
  • [6] LOW-ENERGY GAMMA-RAY SOURCES
    WEST, R
    NUCLEONICS, 1953, 11 (02): : 20 - 23
  • [7] POLARIMETRY OF COSMIC SOURCES OF HARD GAMMA-RAY RADIATION
    KOZLENKOV, AA
    MITROFANOV, IG
    ASTRONOMICHESKII ZHURNAL, 1985, 62 (05): : 1021 - 1024
  • [8] Gamma-Ray Imaging with Spatially Continuous Intensity Statistics
    Greiff, Marcus
    Rofors, Emil
    Robertsson, Anders
    Johansson, Rolf
    Tyllstrom, Rikard
    2021 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2021, : 5257 - 5262
  • [9] DIGITAL IMAGING OF GAMMA-RAY SOURCES WITH DEPTH INFORMATION
    SINGLETON, RM
    RANSOM, PL
    MITTRA, R
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (03) : 239 - 246
  • [10] A gamma-ray imaging method for multiple radionuclides and low-activity radioactive sources
    Fan, Donghai
    Wu, Rui
    Wei, Dengke
    Li, Yingrui
    Tan, Tingting
    Zha, Gangqiang
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2025, 282