Ganglion Cell Layer Thickness Variance Using SPECTRALIS Optical Coherence Tomography

被引:0
|
作者
Mallory, Paul [1 ]
Wagley, Sushant [1 ]
Chen, John [2 ,3 ]
McClelland, Collin M. [1 ]
Downie, Peter A. [1 ]
Lindgren, Bruce [4 ]
Lee, Michael S. [1 ]
机构
[1] Univ Minnesota, Dept Ophthalmol & Visual Neurosci, 420 Delaware St SE,MMC 493, Minneapolis, MN 55455 USA
[2] Mayo Clin, Dept Ophthalmol, Rochester, MN USA
[3] Mayo Clin, Dept Neurol, Rochester, MN USA
[4] Univ Minnesota, Clin & Translat Sci Inst, Minneapolis, MN 55455 USA
关键词
REPRODUCIBILITY;
D O I
10.1097/WNO.0000000000001569
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: To determine the normal variance of the mean macular ganglion cell layer (GCL) volume among subjects without significant ocular pathology using SPECTRALIS optical coherence tomography (OCT). Methods: Fifty subjects underwent a baseline scan using SPECTRALIS OCT followed by 2 more studies with (reg-ON) and without (reg-OFF) eye registration all taken at the same session. The mean GCL volume was measured using built-in SPECTRALIS software. Eyes with macular pathology were excluded. The reproducibility of the measurements of the GCL volume was evaluated with Bland-Altman plots and limits of agreement, intraclass correlation coefficient (ICC), and the coefficient of repeatability (CR). Results: A total of 98 eyes met criteria for the analysis. The mean GCL volume difference was 0.0002 +/- 0.029 and -0.0005 +/- 0.035 mm(3) for scans 1 versus 2 (baseline vs reg-ON) and 3 (baseline vs reg-OFF), respectively. The ICCs were 0.985 and 0.977 for the baseline vs reg-ON and reg-OFF groups. The CR for baseline vs reg-ON was 0.056 while CR for baseline vs reg-OFF was 0.069. Ninety percent of eyes fell within 0.04 mm(3) of test-retest reliability. Conclusions: Our model found a predictable threshold of 0.07 mm(3) or less for SPECTRALIS OCT mean GCL volume variance, which did not significantly change with eye registration in eyes without macular pathology. Clinicians may also consider a threshold of 0.04 mm(3) when determining stable vs progressive changes in mean GCL volume using this device.
引用
收藏
页码:310 / 315
页数:6
相关论文
共 50 条
  • [1] Ganglion Cell Layer Volume by Spectralis Optical Coherence Tomography (OCT) in Multiple Sclerosis
    Davies, Emma C.
    Talman, Lauren S.
    Jacobs, Dina A.
    Wilson, James A.
    Markowitz, Clyde E.
    Galetta, Steven L.
    Frohman, Elliot M.
    Calabresi, Peter A.
    Balcer, Laura J.
    [J]. NEUROLOGY, 2010, 74 (09) : A290 - A290
  • [2] COMPARISON OF GANGLION CELL INNER PLEXIFORM LAYER THICKNESS BY CIRRUS AND SPECTRALIS OPTICAL COHERENCE TOMOGRAPHY IN DIABETIC MACULAR EDEMA
    Hafner, Julia
    Prager, Sonja
    Lammer, Jan
    Kriechbaum, Katharina
    Scholda, Christoph
    Pablik, Eleonore
    Schmidt-Erfurth, Ursula
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (04): : 820 - 827
  • [3] Measurement of ganglion cell layer and inner plexiform layer thickness with optical coherence tomography
    Tan, O
    Li, Y
    Huang, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U675 - U675
  • [4] Comparison of retinal ganglion cell - inner plexiform layer thickness measured by Cirrus and Spectralis optical coherence tomography in eyes with diabetic macular edema
    Hafner, Julia
    Prager, Sonia Gudrun
    Lammer, Jan
    Kriechbaum, Katharina
    Scholda, Christoph
    Schmidt-Erfurth, Ursula
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] Measurement of retinal ganglion cell layer and inner plexiform layer thickness with optical coherence tomography
    Tan, O
    Schuman, J
    Huang, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U928 - U928
  • [6] Evaluation of myopia on retinal nerve fiber layer thickness measured by Spectralis optical coherence tomography
    Zha, Yi
    Zhuang, Jinfei
    Lin, Da
    Feng, Wangqiang
    Zheng, Haihua
    Cai, Jianqiu
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (03) : 2716 - 2720
  • [7] Optical Coherence Tomography as a Biomarker for Differential Diagnostics in Nystagmus: Ganglion Cell Layer Thickness Ratio
    Al-Nosairy, Khaldoon O.
    Quanz, Elisabeth, V
    Biermann, Julia
    Hoffmann, Michael B.
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [8] Evaluation of Retinal Nerve Fiber Layer and Ganglion Cell Layer Thickness in Alzheimer's Disease Using Optical Coherence Tomography
    Jindahra, Panitha
    Hengsiri, Nitchanan
    Witoonpanich, Pirada
    Poonyathalang, Anuchit
    Pulkes, Teeratorn
    Tunlayadechanont, Supoch
    Thadanipon, Kunlawat
    Vanikieti, Kavin
    [J]. CLINICAL OPHTHALMOLOGY, 2020, 14 : 2995 - 3000
  • [9] Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence Tomography
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 467 - 472
  • [10] Comparison of Retinal Thickness in Normal Eyes Using Stratus and Spectralis Optical Coherence Tomography
    Grover, Sandeep
    Murthy, Ravi K.
    Brar, Vikram S.
    Chalam, Kakarla V.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) : 2644 - 2647