Input polarization-independent polarization-sensitive optical coherence tomography using a depolarizer

被引:10
|
作者
Sharma, Shivani [1 ,2 ]
Hartl, Georg [1 ,2 ]
Naveed, Sheeza K. [1 ,2 ]
Blessing, Katharina [1 ]
Sharma, Gargi [1 ]
Singh, Kanwarpal [1 ]
机构
[1] Max Planck Inst Sci Light, Staudtsr 2, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Dept Phys, Staudtstr 7, D-91058 Erlangen, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2020年 / 91卷 / 04期
关键词
SWEPT-SOURCE; SYSTEM;
D O I
10.1063/5.0001871
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Polarization-sensitive optical coherence tomography is gaining attention because of its ability to diagnose certain pathological conditions at an early stage. The majority of polarization-sensitive optical coherence tomography systems require a polarization controller and a polarizer to obtain the optimal polarization state of the light at the sample. Such systems are prone to misalignment since any movement of the optical fiber normally coupled to the light source will change the polarization state of the incident beam. We propose and demonstrate an input polarization-independent polarization-sensitive optical coherence tomography system using a depolarizer that works for any input polarization state of the light source. The change in the optical power at the sample for arbitrary input polarized light for the standard polarization-sensitive optical coherence tomography system was found to be approximately 84% compared to 9% for our proposed method. The developed system was used to measure the retardance and optical axis orientation of a quarter-wave plate and the obtained values matched closely to the expectation. To further demonstrate the capability of measuring the birefringent properties of biological samples, we also imaged the nail bed. We believe that the proposed system is a robust polarization-sensitive optical coherence tomography system and that it will improve the diagnostic capabilities in clinical settings.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Polarization-sensitive optical coherence tomography with a single input polarization state
    Villiger, Martin
    Xiong, Qiaozhou
    Wang, Nanshuo
    Liu, Xinyu
    Liu, Linbo
    Bouma, Brett E.
    2019 IEEE PHOTONICS CONFERENCE (IPC), 2019,
  • [2] Design considerations for polarization-sensitive optical coherence tomography with a single input polarization state
    Lurie, Kristen L.
    Moritz, Tobias J.
    Ellerbee, Audrey K.
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (09): : 2273 - 2287
  • [3] Optical polarization tractography based on polarization-sensitive optical coherence tomography
    Yao, Gang
    Wang, Yuanbo
    Ravanfar, Mohammadreza
    Azinfar, Leila
    Yao, Xuan
    Zhang, Keqing
    Duan, Dongsheng
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [4] Polarization-sensitive interleaved optical coherence tomography
    Duan, Lian
    Marvdashti, Tahereh
    Ellerbee, Audrey K.
    OPTICS EXPRESS, 2015, 23 (10): : 13693 - 13703
  • [5] Endoscopic polarization-sensitive optical coherence tomography
    Pierce, Mark C.
    Shishkov, Milen
    Park, B. Hyle
    Nassif, Nader
    Bouma, Brett E.
    Tearney, Guillermo J.
    de Boer, Johannes F.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [6] Polarization mode dispersion correction in endoscopic polarization-sensitive optical coherence tomography with incoherent polarization input states
    Adams, David C.
    Majid, Adnan
    Suter, Melissa J.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (06) : 3446 - 3460
  • [7] Single-input polarization-sensitive optical coherence tomography through a catheter
    Jones, Georgia L.
    Xiong, Qiaozhou
    Liu, Xinyu
    Bouma, Brett E.
    Villiger, Martin
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (09) : 4609 - 4626
  • [8] POLARIZATION-INDEPENDENT ELECTROOPTIC DEPOLARIZER
    HEISMANN, F
    TOKUDA, KL
    OPTICS LETTERS, 1995, 20 (09) : 1008 - 1010
  • [9] Polarization memory effect in the polarization-sensitive Optical Coherence Tomography system
    Chen, Yueli
    Otis, Linda
    Zhu, Quing
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [10] Single input state polarization-sensitive optical coherence tomography with high resolution and polarization distortion correction
    Xiong, Qiaozhou
    Wang, Nanshuo
    Liu, Xinyu
    Chen, Si
    Liang, Haitao
    Chen, Shufen
    Liu, Linbo
    OPTICS EXPRESS, 2019, 27 (05) : 6910 - 6924