Aerosol release, distribution, and prevention during aerosol therapy: a simulated model for infection control

被引:6
|
作者
Eain, Marc Mac Giolla [1 ]
Cahill, Ronan [2 ]
MacLoughlin, Ronan [1 ,3 ,4 ]
Nolan, Kevin [5 ]
机构
[1] Aerogen Ltd, IDA Business Pk, Galway H91 HE94, Ireland
[2] Univ Coll Dublin, UCD Ctr Precis Surg, Sch Med, Dublin, Ireland
[3] Royal Coll Surg, Sch Pharm & Biomol Sci, Dublin, Ireland
[4] Trinity Coll Dublin, Sch Pharm & Pharmaceut Sci, Dublin, Ireland
[5] Univ Coll Dublin, Sch Mech & Mat Engn, Dublin, Ireland
关键词
COVID-19; aerosol therapy; viral infections; vibrating mesh nebulizer; fugitive emissions; Schlieren imaging; aerosol visualization; EXHALED AIR DISPERSION; NONINVASIVE VENTILATION; DROPLET DISPERSION; DELIVERY; TRANSMISSION; MANAGEMENT; INFLUENZA;
D O I
10.1080/10717544.2021.2015482
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aerosol therapy is used to deliver medical therapeutics directly to the airways to treat respiratory conditions. A potential consequence of this form of treatment is the release of fugitive aerosols, both patient derived and medical, into the environment and the subsequent exposure of caregivers and bystanders to potential viral infections. This study examined the release of these fugitive aerosols during a standard aerosol therapy to a simulated adult patient. An aerosol holding chamber and mouthpiece were connected to a representative head model and breathing simulator. A combination of laser and Schlieren imaging was used to non-invasively visualize the release and dispersion of fugitive aerosol particles. Time-varying aerosol particle number concentrations and size distributions were measured with optical particle sizers at clinically relevant positions to the simulated patient. The influence of breathing pattern, normal and distressed, supplemental air flow, at 0.2 and 6 LPM, and the addition of a bacterial filter to the exhalation port of the mouthpiece were assessed. Images showed large quantities of fugitive aerosols emitted from the unfiltered mouthpiece. The images and particle counter data show that the addition of a bacterial filter limited the release of these fugitive aerosols, with the peak fugitive aerosol concentrations decreasing by 47.3-83.3%, depending on distance from the simulated patient. The addition of a bacterial filter to the mouthpiece significantly reduces the levels of fugitive aerosols emitted during a simulated aerosol therapy, p <= .05, and would greatly aid in reducing healthcare worker and bystander exposure to potentially harmful fugitive aerosols.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [1] Device Cleaning and Infection Control in Aerosol Therapy
    O'Malley, Catherine A.
    RESPIRATORY CARE, 2015, 60 (06) : 917 - 927
  • [2] Device Cleaning and Infection Control in Aerosol Therapy Discussion
    Berlinski
    O'Malley
    Hess
    Fink, James B.
    Restrepo
    Laube
    RESPIRATORY CARE, 2015, 60 (06) : 928 - 930
  • [3] RELEASE - An aerosol model with potential
    Johnson, DW
    INTERNATIONAL CONFERENCE AND WORKSHOP ON MODELING THE CONSEQUENCES OF ACCIDENTAL RELEASES OF HAZARDOUS MATERIALS, 1999, : 169 - 187
  • [4] Global distribution of aerosol optical properties simulated with the sprintars
    Takemura, T
    Nakajima, T
    11TH CONFERENCE ON ATMOSPHERIC RADIATION, 2002, : 113 - 116
  • [5] Remote Aerosol Simulated During the Atmospheric Tomography (ATom) Campaign and Implications for Aerosol Lifetime
    Gao, Chloe Yuchao
    Heald, Colette L.
    Katich, Joseph M.
    Luo, Gan
    Yu, Fangqun
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2022, 127 (22)
  • [6] Evaluating the Use of an Aerosol Box During simulated Intubations
    de Lima, Andres
    Chen, Michael J.
    Abbas, Aamir
    Ramachandran, Satya K.
    Mitchell, John D.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (07)
  • [7] CHRONIC BRONCHITIS - AN ATTEMPT TO CONTROL CHRONIC INFECTION WITH HAEMOPHILUS INFLUENZAE BY AEROSOL THERAPY
    KNOX, K
    ELMES, PC
    FLETCHER, CM
    LANCET, 1955, 1 (JAN15): : 120 - 122
  • [8] Aerosol distribution over Europe: a model evaluation study with detailed aerosol microphysics
    Langmann, B.
    Varghese, S.
    Marmer, E.
    Vignati, E.
    Wilson, J.
    Stier, P.
    O'Dowd, C.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2008, 8 (06) : 1591 - 1607
  • [9] Dust aerosol radiative effects during summer 2012 simulated with a coupled regional aerosol-atmosphere-ocean model over the Mediterranean
    Nabat, P.
    Somot, S.
    Mallet, M.
    Michou, M.
    Sevault, F.
    Driouech, F.
    Meloni, D.
    di Sarra, A.
    Di Biagio, C.
    Formenti, P.
    Sicard, M.
    Leon, J. -F.
    Bouin, M. -N.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2015, 15 (06) : 3303 - 3326
  • [10] Proportional mouse model for aerosol infection by influenza
    McDonald, R. S.
    Sambol, A. R.
    Heimbuch, B. K.
    Brown, T. L.
    Hinrichs, S. H.
    Wander, J. D.
    JOURNAL OF APPLIED MICROBIOLOGY, 2012, 113 (04) : 767 - 778