Independent component analysis applied to the removal of motion artifacts from electrocardiographic signals

被引:64
|
作者
Milanesi, M. [1 ,2 ]
Martini, N. [2 ]
Vanello, N. [2 ]
Positano, V. [3 ]
Santarelli, M. F. [3 ]
Landini, L. [4 ]
机构
[1] Univ Pisa, Dept Elect Syst & Automat, Pisa, Italy
[2] Univ Pisa, Interdept Res Ctr E Piaggio, Pisa, Italy
[3] CNR, Inst Clin Physiol, Pisa, Italy
[4] Univ Pisa, Dept Informat Engn, Pisa, Italy
关键词
independent component analysis; frequency domain; temporal constraint; motion artifacts; electrocardiographic signals;
D O I
10.1007/s11517-007-0293-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Electrocardiographic (ECG) signals are affected by several kinds of artifacts that may hide vital signs of interest. In this study we apply independent component analysis (ICA) to isolate motion artifacts. Standard or instantaneous ICA, which is currently the most addressed ICA model within the context of artifact removal, is compared to two other ICA techniques. The first technique is a frequency domain approach to convolutive mixture separation. The second is based on temporally constrained ICA, which enables the estimation of only one component close to a particular reference signal. Performance indexes evaluate ECG complex enhancement and relevant heart rate errors. Our results show that both convolutive and constrained ICA implementations perform better than standard ICA, thus opening up a new field of application for these two methods. Moreover, statistical analysis reveals that constrained ICA and convolutive ICA do not significantly differ concerning heart rate estimation, even though the latter overcomes the former in ECG morphology recovery.
引用
收藏
页码:251 / 261
页数:11
相关论文
共 50 条
  • [1] Independent component analysis applied to the removal of motion artifacts from electrocardiographic signals
    M. Milanesi
    N. Martini
    N. Vanello
    V. Positano
    M. F. Santarelli
    L. Landini
    [J]. Medical & Biological Engineering & Computing, 2008, 46 : 251 - 261
  • [2] Reducing electrocardiographic artifacts from electromyogram signals with Independent Component Analysis
    Costa Junior, J. D.
    Ferreira, D. D.
    Nadal, J.
    Miranda de Sa, A. M. F. L.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4598 - 4601
  • [3] Multichannel techniques for motion artifacts removal from electrocardiographic signals
    Milanesi, M.
    Martini, N.
    Vanello, N.
    Positano, V.
    Santarelli, M. F.
    Paradiso, R.
    De Rossi, D.
    Landini, L.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2684 - +
  • [4] MOTION ARTIFACTS REMOVAL FOR FNIRS DATA BASED ON INDEPENDENT COMPONENT ANALYSIS
    Shi, Yanhua
    Sun, Gaopeng
    Wang, Haixian
    Leng, Yue
    Yang, Yuankui
    Ge, Sheng
    [J]. 2015 12TH INTERNATIONAL COMPUTER CONFERENCE ON WAVELET ACTIVE MEDIA TECHNOLOGY AND INFORMATION PROCESSING (ICCWAMTIP), 2015, : 40 - 43
  • [5] Removing artifacts from electrocardiographic signals using independent components analysis
    Barros, AK
    Mansour, A
    Ohnishi, N
    [J]. NEUROCOMPUTING, 1998, 22 (1-3) : 173 - 186
  • [6] Independent component analysis applied to the removal of artifacts in combined TMS/EEG recordings
    Takauchi, Shigeki
    Nakajima, Yasoichi
    Kadota, Hiroshi
    Sekiguchi, Hirofumi
    Kansaku, Kenji
    [J]. NEUROSCIENCE RESEARCH, 2007, 58 : S243 - S243
  • [7] Separation of cardiac artifacts from EMG signals with independent component analysis
    Wachowiak, M
    Smoliková, R
    Tourassi, G
    Elmaghraby, AS
    [J]. ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, PROCEEDINGS, 2002, : 23 - 26
  • [8] Study of independent component analysis and removal of ECG artifacts from EEG
    Zhou, Wei-Dong
    Jia, Lei
    Li, Ying-Yuan
    [J]. Zhongguo Shengwu Yixue Gongcheng Xuebao/Chinese Journal of Biomedical Engineering, 2002, 21 (03):
  • [9] Application of an Improved Independent Component Analysis to Artifacts Removal from EEG
    Peng Zhihong
    Luo Junping
    [J]. PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 2784 - 2787
  • [10] Removal Artifacts from EEG Signal Using Independent Component Analysis and Principal Component Analysis
    Turnip, Arjon
    Junaidi, Edy
    [J]. 2014 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY, INFORMATICS, MANAGEMENT, ENGINEERING, AND ENVIRONMENT (TIME-E 2014), 2014, : 296 - 302